General Description 2-11
STATUS lamp
indication
Description
Procedure
On (green)
The server is operating normally.
–
Flashing
(green)
•
The server is operating with the
memory or CPU in degraded
state.
•
A single-bit memory error has
often occurred.
Identify the device in degraded state
by using the BIOS setup utility
"SETUP," and replace it as soon as
possible.
The power is off.
–
POST is in progress.
Wait for a while. The STATUS lamp
turns green when POST is completed.
A CPU error occurred.
A CPU temperature alarm was
detected. (Thermal-Trip)
A timeout occurred when the time
set for the watchdog timer arrived.
A CPU bus error occurred.
Turn the power off and then turn it on.
If the POST screen displays an error
message, take notes of the message,
and contact your sales representative.
Off*
A memory dump request is made.
Wait until the memory dump is
completed.
A temperature alarm was detected.
Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
A voltage alarm was detected.
On (amber)*
The power supply units failed.
Contact your sales representative.
Flashing
(amber)*
A fan alarm was detected.
Check if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
A temperature warning was
detected.
Check if the internal fans are clean
and if the fan units are firmly
connected.
If the STATUS lamp indication does
not change when the fans are normal,
contact your sales representative.
*
Indicate only when the optional remote management card is installed in your server.
Содержание N8100-958F
Страница 12: ...iv This page is intentionally left blank...
Страница 34: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 136: ...4 38 Configuring Your Server This page is intentionally left blank...
Страница 182: ...5 46 Installing the Operating System with Express Setup This page is intentionally left blank...
Страница 206: ...6 24 Installing and Using Utilities This page is intentionally left blank...
Страница 218: ...7 12 Maintenance This page is intentionally left blank...
Страница 316: ...C 2 IRQ This page is intentionally left blank...
Страница 346: ...F 4 Product Configuration Record Table This page is intentionally left blank...