9-20 Upgrading Your Server
Slots to install the PCI board
PCI Slot
#1
#2
#3
#4
#5
Product name
PCIe
64-bit /
100MHz
32-bit /
33MHz
Slot size
(Full-height or LowProfile)
Full-height
Supported board type
–
3.3V
3.3V/5V
N code
Available board size
Short Long Long Short Long
Note
N8503-56F
SCSI controller
–
√
√
√
√
N8103-65F
SCSI controller
–
√
√
√
√
N8103-75F
SCSI controller
–
√
√
√
√
N8103-80F
Disk array controller
–
√
√
√
√
N8103-78F
Disk array controller (SATA)
–
√
√
–
–
Max. 1
(total)
N8104-84
1000BASE-SX adapter
–
√
√
√
√
N8104-103
1000BASE-T adapter
–
√
√
√
√
N8104-113
1000BASE-T adapter
–
√
√
√
√
N8104-111
100BASE-TX adapter
–
√
√
√
√
Max. 4
N8104-86
100BASE-TX adapter (2 ports)
–
√
√
√
√
Max. 2
√
: Available, –: Unavailable
Installation Considerations for RAID Controller
Described below must be considered when installing any of the RAID controller listed below. For
details, refer to the manual that comes with the RAID controller.
–
N8103-78F SATA Disk array controller
–
N8103-80F SCSI Disk array controller
Prepare the hard disk drives and cables appropriate to RAID controller to be installed.
Configure the Logical Settings of hard disk drive.
Prepare the number of hard disk drives required for desired RAID (Redundant Array of
Inexpensive [Independent] Disks) level.
Making hard disks in the disk array configuration or changing the RAID level initializes
hard disks. If the hard disk to be configured in the array has your valuable data stored,
make sure to make a backup copy of the data in another hard disk before installing the
disk mirroring controller board and configuring the array.
Use hard disks of the same capacity and revolution for each pack to configure them in the
array.
The disk array configuration improves disk reliability but provides a smaller disk capacity
than the total capacity of hard disks in the disk array configuration.
When the disk array controller board is replaced, restore the disk array configuration
information in the disk array controller board. Use the configuration utility for the
restoration. Chapter 6 for details.
Содержание N8100-1005F
Страница 1: ...N8100 1005F NEC Express5800 110Ei User s Guide 1st Edition 11 2004 ONL 3125aN 110Ei 100 99 0411...
Страница 16: ...x This page is intentionally left blank...
Страница 33: ...General Description 2 5 Rear View 1 2 3 2 4 5 6 7 8 9 10 11 12...
Страница 104: ...4 42 Configuring Your Server This page is intentionally left blank...
Страница 148: ...5 44 Installing the Operating System with Express Setup This page is intentionally left blank...
Страница 168: ...6 20 Installing and Using Utilities This page is intentionally left blank...
Страница 180: ...7 12 Maintenance This page is intentionally left blank...
Страница 218: ...9 8 Upgrading Your Server Secure the side cover with two screws removed in the removal procedure Screws...
Страница 270: ...10 14 Internal Cabling Diagrams This page is intentionally left blank...
Страница 272: ...A 2 Specifications This page is intentionally left blank...
Страница 314: ...F 4 Product Configuration Record Table This page is intentionally left blank...