5-7
2.3 Power Management
This function conforms DPMS of VESA, and International Energy Star Office Equipment program.
Power Management condition and status for ANALOG Input mode
Power Management condition and status for DIGITAL Input mode
Signals
Power
State
Horizontal
Vertical
Video
USB
Power
Consumption
(
W
)
Recovery
Time (sec) LED status
On
ON
ON
Active
ON
Refer to 3.2
---
Blue
OFF
ON
Blanked
ON
< 3sec.
Orange
ON
OFF
Blanked
ON
< 3sec.
Orange
DPMS
OFF
OFF
Blanked
ON
< 2.3W (Connect
only USB Upstream
cable, GEEA2005
Request)
< 2.0W (Not
connect USB,
Energy Star Ver4.0
Tier 2)
< 3sec.
Orange
DC power
off
-
-
-
OFF
< 1.0W (Connect
only USB Upstream
cable, GEEA2005
Request)
< 1.0W (Not
connect USB,
Energy Star Ver4.0
Tier 2 Request)
< 3sec.
None
AC power
(Vacation
SW) off
-
-
-
-
< 1W
---
None
Signals
Power
State
DE
Horizontal
Vertical
Video
USB
Power
Consumption
Recovery
Times
LED
status
On
Pulses
ON
ON
Active
ON
Refer to 3.2
---
Blue
DPMS
No
Pulses
N/A
N/A
Blanked
ON
< 2.3W (Connect
only USB Upstream
cable, GEEA2005
Request)
< 2.0W (Not
connect USB,
Energy Star Ver4.0
Tier 2)
< 3 sec.
Orange
DC
Power off
-
-
-
-
OFF
< 1.0W (Connect
only USB Upstream
cable, GEEA2005
Request)
< 1.0W (Not
connect USB,
Energy Star Ver4.0
Tier 2 Request)
< 3 sec.
None
AC power
(Vacation
SW) off
-
-
-
-
-
< 1.0W
---
None
Содержание MultiSync 20WGX2 Series
Страница 5: ...MultiSync 20WGX2 User s Manual ...
Страница 45: ...4 8 Page 6 Each Color Temperature Data Adjustment needed Page 5 LCD panel type ...
Страница 116: ...8 1 REPLACEMENT PARTS LIST TABLE OF CONTENTS Page Model 20WGX2 B For Europe 8 2 ...
Страница 140: ...11 1 PACKING SPECIFICATION TABLE OF CONTENTS Page B Version 11 2 ...
Страница 141: ...11 2 ...
Страница 143: ...12 1 Revision History Revision Revision New Issue 1st Edition 2006 03 ...