8. STANDBY FUNCTIONS
In order to fully exploit the
µ
PD75512 low power dissipation, CPU operation can be stopped by setting the unit
to the standby mode, thus, further reducing power dissipation. The
µ
PD75512 features two standby modes, a STOP
mode and a HALT mode.
Table 8-1 Status in Standby Mode
Can operate only when the external
SCK0 input is selected as the serial
clock
Instruction for Setting
STOP instrtuction
HALT instruction
Can be set only when operating on
the main system clock
Can be set when operating either on
the main system clock or the subsys-
tem clock
Item
Mode
STOP Mode
HALT Mode
Clock Oscillator
Only the main system clock can stop
its operation.
Only the CPU clock
Φ
stops its
operation. (oscillation continues)
Basic Interval
Timer
Does not operate
Operates (Sets IRQBT with the
reference time interval)
System Clock at the Time of
Setting
Serial Interface
(Channel 0)
Operates when the timer system
clock is operating or external SCK0 is
selected
Serial Interface
(Channel 1)
Can operate only when the external
SCK1 input is selected as the serial
clock
Operates only when the main system
clock is operating
Timer/Event
Counter
Can only operate when the TI0 pin
input is selected as system clock
Operates only when the main system
clock is operating
Clock Timer
Operates when f
XT
is selected as the
count clock
Can operate
A/D Converter
Does not operate
Timer/Pulse
Generator
Operates only when the main system
clock is operating
Does not operate
Operates only when the main system
clock is operating
Release Signal
CPU
Does not operate
Timer/Pulse
Generator
INT1, INT2, and INT4 can operate, but INT0 cannot operate
An interrupt request signal from a piece of hardware, whose operation is
enabled by the interrupt enable flag, or the RESET signal input
Operation
Status
Содержание mPD75512