Specifications - MD213MG

Monitor Specifications

MD213MG Monitor

Notes

LCD Module

Diagonal:

54.0 cm/21.3 inches

Active matrix; thin film transistor (TFT)

Viewable Image Size:

54.0 cm/21.3 inches

liquid crystal display (LCD); SA - SFT (IPS);

Native Resolution (Pixel Count):

1536 x 2048 (Portrait)

0.212 mm dot pitch; 1450 cd/m

2

 max

2048 x 1536 (Landscape)

luminance, 400 cd/m

2

 calibrated luminance;

900:1 contrast ratio, typical.

Input Signal

Video:

ANALOG 0.7 Vp-p/75 Ohms

Digital Input: DVI

Sync:

Separate sync.TTL Level
Horizontal sync. Positive/Negative
Vertical sync. Positive/Negative
Composite sync. Positive/Negative

Display Tones

10bit: 1024 (10bit) shades of gray from

When used with an recommended 10bit

a pallet of 12241 (13.5bit)

display card

8bit: 256 (8bit) shades of gray from

When used with an recommended 8bit

a pallet of 12241 (13.5bit)

display card

Synchronization Range

Horizontal:

31.5 kHz to 95.4 kHz (Digital)

Automatically

31.5 kHz to 93.8 kHz (Analog)

Automatically

Vertical:

30.0 Hz to 85 Hz

Automatically

Clock Frequency

162 MHz

Viewing Angle

Left/Right:

±88° (CR > 10)

Up/Down:

±88° (CR > 10)

Image Formation Time

27 ms (Typ.)

13 ms (Gray to gray, typical)

Resolutions Supported

640 x 480*

1

 at 60 Hz to 85 Hz

(Some systems may not support

720 x 400*

1

 at 70 Hz to 85 Hz

all modes listed).

800 x 600*

1

 at 56 Hz to 85 Hz

832 x 624*

1

 at 75 Hz

1024 x 768*

1

 at 60 Hz to 85 Hz

1152 x 864*

1

 at 70HZ to 85Hz

1152 x 870*

1

 at 75Hz

1280 x 960*

1

 at 60 Hz

1280 x 1024*

1

 at 60 Hz to 85 Hz

1600 x 1200*

1

 at 60 Hz

1920 x 1200*

1

 at 60 Hz (Analog)

1920 x 1200*

1

 at 60 Hz (Digital)

NEC DISPLAY SOLUTIONS cites

2048 x 1536*

1

 at 35 Hz

recommended resolution for optimal

2048 x 1536 at 60 Hz (Digital).........................display performance.

Active

Landscape:

Horiz.: 433 mm/17.0 inches

Vert.: 325 mm/12.8 inches

Display Area

Portrait:

Horiz.: 325 mm/12.8 inches

Vert.: 433 mm/17.0 inches

Power Supply

AC 100-240 V ~ 50/60 Hz

Current Rating

1.1 - 0.46 A

For Mexico 2.0A

Dimensions

Landscape:

467.8 mm (W) x 434.3 - 584.3 mm (H) x 306 mm (D)
18.4 inches (W) x 17.1 - 23.0 inches (H) x 12.0 inches (D)

Portrait:

361.6 mm (W) x 487.4 - 637.4 mm (H) x 306 mm (D)
14.2 inches (W) x 19.2 - 25.1 inches (H) x 12.0 inches (D)

Height Adjustment:

150 mm / 5.9 inches

Weight

10.9 kg (24.0 lbs)

Environmental Considerations

Operating Temperature:

5°C to 35°C/41°F to 95°F

Humidity:

30% to 80%

Altitude:

-1,246 to 9,842 Feet/-380 to 3,000 m

Atmospheric pressure:

700hPa to 1060hPa

Transport/Storage Temperature:

-10°C to 60°C/14°F to 140°F

Humidity:

10% to 85%

Altitude:

-1,246 to 40,000 Feet/-380 to 12,192 m

Atmospheric pressure:

200hPa to 1060hPa

*1 Interpolated Resolutions: When resolutions are shown that are lower than the pixel count of the LCD module, text may appear different. This is normal and
necessary for all current flat panel technologies when displaying non-native resolutions full screen. In flat panel technologies, each dot on the screen is actually
one pixel, so to expand resolutions to full screen, an interpolation of the resolution must be done.

NOTE: 

Technical specifications are subject to change without notice.

Содержание MD213MC - MultiSync - 21.3" LCD Monitor

Страница 1: ...MD212MC MD213MC MD213MG INSTALLATION MAINTENANCE GUIDE...

Страница 2: ...ions Ltd in Austria Benelux Denmark France Germany Italy Norway Spain Sweden U K All other brands and product names are trademarks or registered trademarks of their respective owners This symbol warns...

Страница 3: ...atient environment and IEC 60601 1 certified equipment inside the patient environment Equipment connected to the analog or digital interfaces must comply with the respective IEC standards e g IEC 6095...

Страница 4: ...a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try t...

Страница 5: ...let and refer servicing to qualified service personnel under the following conditions When the power supply cord or plug is damaged If liquid has been spilled or objects have fallen into the monitor I...

Страница 6: ...wered on This feature can be turned on or off in the Advanced OSD In case you find such bright Brand Logo annoying in your reading room environment you may easily switch this off By keeping the EXIT b...

Страница 7: ...DVI D to DVI D cable 1 Quick Reference Guide CD ROM x 2 Cable Cover Power Cord Type of power cord included will depend on the where the LCD monitor is to be shipped Quick Reference Guide DVI D to DVI...

Страница 8: ...mode Refer to the Screen rotation section in this manual 4 Place hands on each side of the monitor to tilt the LCD panel to a 30 angle and lift up to the highest position Figure C 1 5 Connect all cab...

Страница 9: ...0 Turn on the monitor with power switch on the top Portrait or left side Landscape of the monitor Figure E 1 Turn on the computer NOTE DO NOT switch on off repeatedly 11 No touch auto adjust automatic...

Страница 10: ...f the monitor and lift up to the highest position Figure RL 1 To rotate screen place hands on each side of the monitor screen and turn clockwise from Landscape to Portrait or counter clockwise from Po...

Страница 11: ...the flexible arm for detailed instructions To fulfill the safety requirements the monitor must be mounted to an arm which guaranties the necessary stability under consideration of the weight of the m...

Страница 12: ...tton for at least 3 seconds to display the visual inspection grayscale drawing and check the display performance Enters the OSD Control menu Enters OSD sub menus Changes the input source when not in t...

Страница 13: ...SIZE H SIZE Analog input only Adjust the horizontal size by increasing or decreasing this setting If the AUTO Adjust function do not give you a satisfactory picture setting a further tuning can be per...

Страница 14: ...LUE BASE Color temperature setting for Blue Base x ray film simulation NOTE To reset a poor image setting turn on the monitor by using the power switch on the top in portrait mode or left side in land...

Страница 15: ...eset choices are 10 120 seconds by 5 second increments OSD LOCK OUT This control completely locks out access to all OSD control functions When attempting to activate OSD controls while in the Lock Out...

Страница 16: ...lution other than the optimized resolution is used After power is turned on or when there is a change of input signal or the video signal doesn t have proper resolution the Resolution Notifier window...

Страница 17: ...he blue component of the image Press Left or Right to adjust Analog input only R FINE Adjusts the FINE setting of the RED component of the image Analog input only Press Left or Right to adjust G FINE...

Страница 18: ...ot clock For this a Moir test pattern could be used This function may alter the width of the picture Use left Right Menu to center the image on the screen If the V Size H Size is wrongly calibrated th...

Страница 19: ...ted when CUSTOM is selected PRIORITY only for MD212MC MD213MC Sets gamma characteristics for optimum viewing of contrast or color GRAYSCALE Optimizes gamma for contrast COLOR Optimizes gamma for color...

Страница 20: ...nput signal is lost STANDARD Monitor enters power save mode automatically when the input signal is lost Response Improve Turns the RESPONSE IMPROVE function on or off Response Improve may reduce blurr...

Страница 21: ...in the corner of the screen Signal information is either On Off Resolution Notifier The optimal resolution is 1200 x 1600 in portrait mode or 1600 x 1200 in landscape mode for MD212MC and 1536 x 2048...

Страница 22: ...ker than normal or have color distortion Use of the Clamp position control will adjust images to their normal state TagA CALIBRATION Selects the Calibration mode page 21 SELF TEST MODE Displays an all...

Страница 23: ...ontamination DO NOT press the calibrator against the display panel KEY MAP UP DOWN Changes from setting to setting LEFT RIGHT Changes the setting selection ie SELF or COPY SELECT Moves to the next ste...

Страница 24: ...y A must display a white screen Enter the Advanced OSD by pressing RESET and EXIT Use LEFT and RIGHT keys to move into Tag A and select SELF TEST MODE 2 Select COPY in the Mode selection in Display B...

Страница 25: ...UNING MODE 1 1 MD213MG does not have FINE TUNING MODE 10 At the FINE TUNING MODE message Figure 13 press SELECT if the calibration is satisfactory If the calibration is unsatisfactory there are two op...

Страница 26: ...17 3 Select the Color setting in COLOR 2 selection and Gamma setting in GAMMA selection 2 MD213MG does not have COLOR selection 4 Press SELECT to start the DICOM MEASUREMENT This may take several min...

Страница 27: ...o 75 Hz NEC DISPLAY SOLUTIONS cites 1440 x 900 1 at 60 Hz to 75 Hz recommended resolution for optimal 1600 x 1200 1 at 60 Hz display performance Active Landscape Horiz 432 mm 17 0 inches Vert 324 mm 1...

Страница 28: ...x 1200 1 at 60 Hz Analog 1920 x 1200 1 at 60 Hz Digital NEC DISPLAY SOLUTIONS cites 2048 x 1536 1 at 35 Hz recommended resolution for optimal 2048 x 1536 at 60 Hz Digital display performance Active La...

Страница 29: ...at 75Hz 1280 x 960 1 at 60 Hz 1280 x 1024 1 at 60 Hz to 85 Hz 1600 x 1200 1 at 60 Hz 1920 x 1200 1 at 60 Hz Analog 1920 x 1200 1 at 60 Hz Digital NEC DISPLAY SOLUTIONS cites 2048 x 1536 1 at 35 Hz rec...

Страница 30: ...djust the colors on your screen and customise the color accuracy of your monitor to a variety of standards OSD On Screen Display Controls Allow you to quickly and easily adjust all elements of your sc...

Страница 31: ...or shows rough images only Image is displayed only roughly pixels are missing and OSD warning OUT OF RANGE is displayed Either signal clock or resolution is too high Choose one of the supported modes...

Страница 32: ...in Japan or http www necdisplay com in USA Energy Saving This monitor features an advanced energy saving capability When a VESA Display Power Management Signalling DPMS Standard signal is sent to the...

Отзывы: