Chapter3
Power-On and Power-Off
3.1
Power-On and Power-On Sequence
Turning on the power of the product initiates a self test. The self test takes several minutes, but no
other operation can be performed during the test.
Before turning on the power, check that the fastening screw for transportation has been
removed (see "1.8
Removal of shipment Stabilizer
3.2
Starting the System
When starting the system, first start the LIbrary (and any peripheral devices connected to the server or
workstation), then turn the server or workstation's power on to start the system.
1)
Push the power switch button located on the front of the unit to turn on the power.
2)
When the power is supplied, [Power LED] goes on green and the system starts power-on test.
3)
When the power-on test successfully completed, a [Ready] appears on the operator panel.
If a cartridge is loaded into the drive before the system is started, errors may occur
when reading or writing data stored in the cartridge.
3.3
Shutting Down the System
When shutting down the system, first turn off the power to the server or workstation, then the power to
the Library (and any peripheral devices connected to the server or workstation) to shut down the system.
When shutting down the system, use your backup application or check for messages on
the LCD to make sure that no cartridges have been loaded into the cartridge drive. If
the system is shut down while a cartridge is loaded in the cartridge drive, the next time
the system is started errors may occur when reading or writing data stored in the
cartridge, which can lead to malfunctions in the cartridge or the Library.
Do not shut down and restart the system while the Library is operating. Make sure that
the LIbrary has stopped before shutting down the system or restarting it.
3.4
Power-Off and Power-Off Sequence
1)
Push the power switch button (for about 1sec) located on the front of the unit to turn off the power.
2)
The shutdown processing is begun, and the power supply is turned off automatically.
When the data cartridge is stored in the drive, power supply OFF is not carried out automatically.
After choosing [NO],take out a data cartridge from a drive and carry out power supply OFF again, or
choose [Yes], and turn off a power supply as it is.
However, if power supply OFF is carried out where a data cartridge is stored in a drive, it will become
a cause of failure of a data cartridge and this equipment.
In moving of Library, turn off the power supply of library(see “9.8
”)
Содержание LL030F
Страница 27: ...xxvi This page is intentionally blank...
Страница 42: ...15 4 Remove the cushioning material to take out the library 5 Open the plastic bag and remove the library...
Страница 73: ...46 4 4 Top Menu After Log in the following screen is displayed Figure 4 9 Root screen of Top Menu...
Страница 206: ...179 4 Remove the four screws anchoring the bezel and demount it Screws...
Страница 235: ...208 CONTROLLER BOARD 00CF Reserved...
Страница 239: ...212 Maintenance chassis 00FD Reserved 00FE Reserved 00FF Reserved...