-204-
Library error code (10/16)
Code(
H
)
Description
Panel
Indicator
Action
0090
Y motion error #1 (In Y motion, defect in data of
origin sensor when picker moves to target position.)
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
0090
To power cycle the library.
0091
Y motion error #2 (Detected motor step-out in Y
motion.)
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
0091
To power cycle the library.
0092
Y motion error #3 (Detected motor step-out in
initializing.)
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
0092
To power cycle the library.
0093
Reserved
CHK
0093
0094
Cannot detect Y origin position during initializing.
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
0094
To power cycle the library.
0095
Reserved
-
0096
Reserved
-
0097
Reserved
-
0098
When the calibration operated, the lock position
was not able to be detected.
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
0098
To power cycle the library.
0099
Reserved
-
009A
Reserved
-
009B
Reserved
-
009C
Reserved
-
009D
Reserved
-
009E
Reserved
-
009F
Magazine was removed during Y motion.
(FRU)
Maintenance chassis, CONTROLLER BOARD
CHK
009F
1. Check magazine.
2. To power cycle the library.
Содержание LL030F
Страница 27: ...xxvi This page is intentionally blank...
Страница 42: ...15 4 Remove the cushioning material to take out the library 5 Open the plastic bag and remove the library...
Страница 73: ...46 4 4 Top Menu After Log in the following screen is displayed Figure 4 9 Root screen of Top Menu...
Страница 206: ...179 4 Remove the four screws anchoring the bezel and demount it Screws...
Страница 235: ...208 CONTROLLER BOARD 00CF Reserved...
Страница 239: ...212 Maintenance chassis 00FD Reserved 00FE Reserved 00FF Reserved...