OFF_HOUR: Turn off time (hour)
'0'-'0'(30h, 30h): 00
|
'1'-'7'(31h, 37h): 23 (=17h)
'1'-'8'(31h, 38h): Off timer isn't set.
OFF_MIN: Turn off time (minute)
'0'-'0'(30h, 30h): 0
|
'3'-'B'(33h, 42h): 59 (=3Bh)
'3'-'C'(33h, 43h): Off timer isn’t set.
INPUT: Timer input
'0'-'0'(30h, 30h): RGB1(DVI-D)
'0'-'1'(30h, 31h): RGB2(D-SUB)
'0'-'2'(30h, 32h): RGB3(BNC)
'0'-'3'(30h, 33h): DVD/HD
'0'-'4'(30h, 34h): VIDEO
'0'-'5'(30h, 35h): VIDEO(S)
'0'-'7'(30h, 37h): It is o
perates by last memory input
WD: Week setting
bit 0: Monday
bit 1: Tuesday
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
FL: Option
bit 0: 0(30h):once 1(31h):Everyday
bit 1: 0(30h):once 1(31h):Every week
bit 2: 0:Disable 1:Enable
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 “Check code” for a BCC calculation.
Delimiter
CR (0Dh): End of packet
10.2 Schedule Write
This command is used in order to write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header Message
Check
code
Delimiter
SOH-'0'-Monitor ID-'0'-'A'-'1'-'6'
STX-'C'-'2'-'1'-'4'-PG-ON HOURS-ON MIN-OFF
HOURS-OFF Min-INPUT-WD-FL-ETX
BCC CR
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller
'A' (41h): Message type is "Command"
'1'-'6'(31h, 36h): Message length.