background image

 
 
 

(4/137) 

I. Application 

 

This document defines the communications method for control of the NEC LCD monitor, MultiSync P403/ 

P463 /P553 when using an external controller.

 

 

Содержание LCD Monitor

Страница 1: ...limiter 14 5 Message type 15 5 1 Get current Parameter from a monitor 15 5 2 Get parameter reply 16 5 3 Set parameter 18 5 4 Set parameter reply 19 5 5 Commands 20 5 5 1 Save Current Settings 20 5 5 2 Get Timing Report and Timing reply 21 5 5 3 NULL Message 22 IV Control Commands 23 6 Typical procedure example 23 6 1 How to change the Backlight setting 23 6 2 How to read the measurement value of t...

Страница 2: ...ead Reply 76 14 2 Direct TV Chanel Write Reply 77 15 Daylight Saving read write 78 15 1 Daylight Saving Read 78 15 2 Daylight Saving Write 80 16 Firmware Version 82 16 1 Firmware Version Read 82 17 Auto ID 84 17 1 Auto ID Execute 84 17 2 Auto ID Complete 86 17 3 Auto ID Reset 88 18 Input Name 89 18 1 Input Name Read 89 18 2 Input Name Write 91 18 3 Input Name Reset 93 19 Auto Tile Matrix 95 19 1 A...

Страница 3: ...ng Copy Read 115 21 2 Setting Copy Write 117 21 3 Setting Copy Start 119 22 Security Enable 121 22 1 Security Enable Read 121 22 2 Security Enable Write 123 23 LAN MAC Address 125 23 1 LAN MAC Address Read 125 24 Proof of Play 127 24 1 Start Proof of Play 127 24 2 Stop Proof of Play 129 24 3 Get Proof of Play Current 131 24 4 Get Proof of Play Total Number 133 24 5 Get Proof of Play Number to Numb...

Страница 4: ... 4 137 I Application This document defines the communications method for control of the NEC LCD monitor MultiSync P403 P463 P553 when using an external controller ...

Страница 5: ...32C Remote control Connector 9 pin D Sub Cable Cross reversed cable or null modem cable Please refer Controlling the LCD monitor via RS 232C Remote control on User s manual 2 2 LAN control Connector RJ 45 10 100 BASE T Cable Category 5 or higher LAN cable ...

Страница 6: ... 6 137 Please refer Controlling the LCD monitor via LAN control on User s manual ...

Страница 7: ...ication layer Transport layer TCP Using the payload of TCP segment 4 IP address Default Automatic setup If you need to change Please refer Network settings on User s manual 5 Port No 7142 Fixed Note The monitor will disconnect the connection if no packet data is received for 15 minutes And the controller PC has to re connect to control the monitor again after 15 minutes or more 3 3 Communication t...

Страница 8: ...ted item The controller sends commands to set an adjusted value The monitor replies to the controller for confirmation The controller sends command to get a value for confirmation The monitor replies an adjusted value The controller requests to store the adjusted value to the monitor Command Command Reply The control does not suitable for above fixed protocol use the proper command for each contro...

Страница 9: ...80 90h 6 46h F 31 5Fh 56 78h 81 91h 7 47h G 32 60h 57 79h 82 92h 8 48h H 33 61h 58 7Ah 83 93h 9 49h I 34 62h 59 7Bh 84 94h 10 4Ah J 35 63h 60 7Ch 85 95h 11 4Bh K 36 64h 61 7Dh 86 96h 12 4Ch L 37 65h 62 7Eh 87 97h 13 4Dh M 38 66h 63 7Fh 88 98h 14 4Eh N 39 67h 64 80h 89 99h 15 4Fh O 40 68h 65 81h 90 9Ah 16 50h P 41 69h 66 82h 91 9Bh 17 51h Q 42 6Ah 67 83h 92 9Ch 18 52h R 43 6Bh 68 84h 93 9Dh 19 53h ...

Страница 10: ...Case sensitive Refer to section 4 2 Message block format for more details ASCII A 41h Command ASCII B 42h Command reply ASCII C 43h Get current parameter from a monitor ASCII D 44h Get parameter reply ASCII E 45h Set parameter ASCII F 46h Set parameter reply 6th 7th bytes Message Length Specify the length of the message that follows the header from STX to ETX This length includes STX and ETX The b...

Страница 11: ...eply for more details 3 Set parameter The controller sends this message to change a setting of the monitor Message format of the Set parameter is as follows Refer to section 5 3 Set parameter for more details 4 Set Parameter reply The monitor replies with this message for a confirmation of the Set parameter message Message format of the Set parameter reply is as follows Refer to section 5 4 Set pa...

Страница 12: ... power control Schedule etc Refer to section 5 5 Commands message for more details 6 Command reply The monitor replies to a query from the controller Command reply message format depends on each command Refer to section 5 5 Commands message for more details ...

Страница 13: ...30h xor 30h xor 31h xor 30h xor 30h xor 30h xor 36h xor 34h xor 03h 77h Header Message Check code Delimiter 27 26 25 24 23 22 21 20 SOH D0 Reserved D1 Destination D2 Source D3 Type D4 Length H D5 Length L D6 STX D7 Data D8 ETX Dn Check code Dn 1 P P P P P P P P Header Message SOH Reserved Destination Address Source Address Message type Message length STX OP code page OP code Set Value ETX Check co...

Страница 14: ... 14 137 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter ...

Страница 15: ...em OP code page data must be encoded to ASCII characters Ex The byte data 02h must be encoded to ASCII characters 0 and 2 30h and 32h OP code page 02h OP code page Hi ASCII 0 30h OP code page Lo ASCII 2 32h Refer to Operation code table Appendix A 4th 5th bytes OP code Operation code Refer to Appendix A Operation code table for each item OP code data must be encoded to ASCII characters Ex The byte...

Страница 16: ... code Operation code These bytes indicate a replying item s OP code This returned value from the monitor is encoded to ASCII characters Refer to the operation code table Ex The byte data 1Ah is encoded to ASCII character 1 and A 31h and 41h 8th 9th bytes Type Operation type code 00h Set parameter 01h Momentary Like the Auto Setup function which automatically changes the parameter This returned val...

Страница 17: ... 17 137 18th byte ETX End of Message ASCII ETX 03h ...

Страница 18: ... 0 and 2 30h and 32h Refer to the Operation code table 4th 5th bytes OP code Operation code This OP code data must be encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to the Operation code table 6th 9th bytes Set value 16bit This data must be encoded to ASCII characters Ex 0123h 1st MSB ASCII 0 30h 2nd ASCII 1 31h 3rd ASCII 2 32h 4th LSB ASCII 3 33h 10...

Страница 19: ...or is encoded to ASCII characters Ex OP code 1Ah OP code Hi ASCII 1 31h OP code Lo ASCII A 41h Refer to Operation code table 8th 9th bytes Type Operation type code ASCII 0 0 30h 30h Set parameter ASCII 0 1 30h 31h Momentary Like Auto Setup function that automatically changes the parameter 10th 13th bytes Max value Maximum value that monitor can accept 16bits Reply data from the monitor is encoded ...

Страница 20: ...requests for the monitor to store the adjusted value Send OC 30h 43h as Save current settings command Complete Save Current setting command packet as follows ASCII 01h 30h 41h 30h 41h 30h 34h 02h 30h 43h 03h CHK 0Dh SOH 0 A 0 A 0 4 STX 0 C ETX CHK CR The monitor replies the packet for confirmation as follows SOH 0 0 A B 0 6 STX 0 0 0 C ETX CHK CR Command code STX 0 C ETX ...

Страница 21: ...plies status as the following format SS Timing status byte Bit 7 1 Sync Frequency is out of range Bit 6 1 Unstable count Bit 5 2 Reserved Don t care Bit 1 1 Positive Horizontal sync polarity 0 Negative Horizontal sync polarity Bit 0 1 Positive Vertical sync polarity 0 Negative Vertical sync polarity H Freq Horizontal Frequency in unit 0 01kHz V Freq Vertical Frequency in unit 0 01Hz Ex When H Freq...

Страница 22: ... or not expected Following operations need a certain time for to execute so the monitor will return this message when another message is received during execution Power ON Power OFF Auto Setup Input PIP Input Auto Setup and Factory reset Complete NULL Message command packet as follows 01h 30h 30h 41h 42h 30h 34h 02h 42h 45h 03h CHK 0Dh SOH 0 0 A B 0 4 STX B E ETX CHK CR Command code STX B E ETX ...

Страница 23: ... 0 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies with current Backlight setting and capability to support this operation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set ...

Страница 24: ... confirmation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 F 46h Message Type is Set parameter reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 0 30h 30h Result code No error 0 0 30h 30h Operation code page number is 0 1 0 31h...

Страница 25: ...Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID which you want to store the setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 0 4 30h 34h Message length is 4 bytes Message STX 02h Start of Message 0 C 30h 43h Command code is 0Ch as Save current settings ETX 03h End of Message Check code BCC Block Check Code Refer to the se...

Страница 26: ... 30h 30h 30h 31h Select the temperature sensor 1 01h 00h No meaning 01h Sensor 1 02h Sensor 2 03h Sensor 3 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 2 The monitor replies for confirmation Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicat...

Страница 27: ...de page number is 2 7 9 37h 39h Operation code is 79h in the page 2 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet Step 4 The monitor replies a temperature of selected sensor Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID...

Страница 28: ...k code for a BCC calculation Delimiter CR 0Dh End of packet Readout value Temperature Celsius Binary Hexadecimal 125 0 0000 0000 1111 1010 00FAh 25 0 0000 0000 0011 0010 0032h 0 5 0000 0000 0000 0001 0001h 0 0000 0000 0000 0000 0000h 0 5 1111 1111 1111 1111 FFFFh 25 0 1111 1111 1100 1110 FFCEh 55 0 1111 1111 1001 0010 FF92h ...

Страница 29: ... 100K step COLOR TEMPERATURE CUSTOM 00h 14h 9 10000K 11 0Bh CUSTOM R GAIN 00h 16h 0 Dark 255 FFh Bright B GAIN 00h 18h 0 Dark 255 FFh Bright G GAIN 00h 1Ah 0 Dark 255 FFh Bright COLOR CONTROL 00h RED 9Bh YELLOW 9Ch GREEN 9Dh CYAN 9Eh BLUE 9Fh MAGENTA A0h 0 100 64h center 200 C8h GAMMA CORRECTION 02h 68h 0 No mean 1 NATIVE 4 2 2 8 2 4 7 S GAMMA 5 DICOM SIM 6 PROGRAMABLE1 13 0Bh PROGRAMABLE2 14 0Ch ...

Страница 30: ...RESET PICTURE 02h CBh 0 No mean 2 Reset Picture category Momentary AUTO SETUP 00h 1Eh 0 No mean 1 Execute Momentary AUTO ADJUST 10h B7h 0 No mean 1 OFF 2 ON H POSITION 00h 20h 0 Left side Max Right side Depends on a display timing V POSITION 00h 30h 0 Bottom side Max Top side Depends on a display timing CLOCK 00h 0Eh 0 Max PHASE 00h 3Eh 0 Max H RESOLUTION 02h 50h 0 Low Max High ADJUST V RESOLUTION...

Страница 31: ...768 Item 5 1366x768 ASPECT 02h 70h 0 No mean 1 NORMAL 2 FULL 3 WIDE 4 ZOOM 6 DYNAMIC 7 1 1 Wide Dynamic A V mode only ZOOM 02h 6Fh 0 No mean 1 x1 00 100 2 x1 01 101 201 C9h x3 00 300 H ZOOM 02h 6Ch 0 No mean 1 x1 00 100 2 x1 01 101 201 C9h x3 00 300 V ZOOM 02h 6Dh 0 No mean 1 x1 00 100 2 x1 01 101 201 C9h x3 00 300 H POS 02h CCh 0 Left side 200 C8h Right side Zoom Control V POS 02h CDh 0 Down side...

Страница 32: ...o mean 1 MAIN AUDIO 2 PIP AUDIO LINE OUT 10h 81h 0 No mean 1 FIXED 2 VARIABLE SURROUND 02h 34h 0 No mean 1 OFF 2 ON AUDIO INPUT 02h 2Eh 0 No mean 1 IN1 2 IN2 3 IN3 4 HDMI 6 OPTION 7 DPORT 8 DPORT2 9 DPORT3 10 0Ah HDMI2 AUDIO RESET AUDIO 02h CBh 0 No mean 4 Reset Audio category Momentary OFF TIMER 02h 2Bh 0 Off 1 1 hour 24 18h 24 hours 1 hour step ENABLE 02h E5h 0 No mean 1 No 1 Enable 7 No 7 Enabl...

Страница 33: ...CTURE Full PIP SIZE 10h B9h 0 small 80 large X 02h 74h 0 left 100 64h right PIP POSITION Y 02h 75h 0 top 100 64h bottom ASPECT 10h 83h 0 No mean 1 NORMAL 2 FULL 3 WIDE 4 ZOOM MODE 10h 08h 0 No mean 1 OFF 2 HORIZONTAL 3 VERTICAL POSITION 10h 09h 0 Top Left 100 64h Bottom Right SIZE 10h 0Ah 0 1 Do not set 2 Narrow 2 24 8 Wide 8 24 BLEND 10h 0Bh 0 No mean 1 10 10 0Ah 100 DETECT 10h 0Ch 0 No mean 1 AU...

Страница 34: ...ISH 5 JAPANESE 6 ITALIAN 7 SWEDISH 9 RUSSIAN 14 0Eh CHINESE OSD Language MENU DISPLAY TIME 00h FCh 0 1 Do not set 2 10s 3 15s 48 30h 240s 5sec step X 02h 38h 0 Left 255 FFh Right OSD POSITION Y 02h 39h 0 Down 255 FFh Up INFORMATION OSD 02h 3Dh 0 Disable information OSD 3 10 0Ah OSD timer seconds MODEL NAME Refer to chapter 12 SERIAL Refer to chapter 12 FIRMWARE1 Refer to chapter 16 FIRMWARE2 Refer...

Страница 35: ...oup J AUTO ID Refer to chapter 17 AUTO ID RESET Refer to chapter 17 IR LOCK SETTING 02h 3Fh 0 No mean 1 NORMAL 4 LOCK H MONITOR 02h D0h 0 No mean 1 10 0Ah Number of H division V MONITOR 02h D1h 0 No mean 1 10 0Ah Number of V division POSITION 02h D2h 0 No mean 1 100 64h TILE COMP 02h D5h 0 No mean 1 NO 2 YES TILE MATRIX ENABLE 02h D3h 0 No mean 1 NO 2 YES TILE MATRIX MEM 10h 4Ah 0 No mean 1 COMMON...

Страница 36: ...Select sensor Page02h OPcode78h 1 SENSOR 1 2 SENSOR 2 3 SENSOR 3 COOLING FAN 02h 7Dh 0 No mean 1 AUTO 2 ON FAN SPEED 10h 3Fh 0 No mean 1 HIGH 2 LOW SENSOR1 10h E0h E1h E0h Set centigrade 0 65535 FFFFh E1h Set offset from max value 0 10 0Ah SENSOR2 10h E2h E3h E2h Set centigrade 0 65535 FFFFh E3h Set offset from max value 0 10 0Ah FAN CONTROL SENSOR3 10h E4h E5h E4h Set centigrade 0 65535 FFFFh E5h...

Страница 37: ...DEO DETECT 4 CUSTOM DETECT PRIORITY1 10h 2Eh PRIORITY2 10h 2Fh CUSTOM DETECT PRIORITY3 10h 30h 0 No mean 1 VGA 2 RGB HV 3 DVI 4 HDMI Set only 5 VIDEO 7 S VIDEO 12 0Ch Y Pb Pr 13 0Dh OPTION 14 0Eh Y Pb Pr2 15 0Fh DPORT 16 10h DPORT2 17 11h HDMI 18 12h HDMI2 128 80h DPORT3 ON OFF 10h 3Dh 0 No mean 1 OFF 2 ON SOG PEAK 10h 37h 0 32 20h GAIN 10h 38h 0 32 20h R H POSITION 02h 58h 0 7 G H POSITION 02h 59...

Страница 38: ...PORT F2h 0 No mean 1 1 1a 2 1 2 TERMINA L SETTING HDMI SIGNAL 10h 40h 0 No mean 1 EXPAND 2 RAW DEINTERLACE 02h 25h 0 No mean 1 Off 2 ON COLOR SYSTEM 02h 21h 0 No mean 1 NTSC 2 PAL 3 SECAM 4 AUTO 5 4 43NTSC 6 PAL 60 OVER SCAN 02h E3h 0 No mean 1 OFF 2 ON OPTION POWER 10h 41h 0 OFF 1 ON AUDIO 10h B0h 0 No mean 1 ANALOG 2 DIGITAL OFF WARNIN G 10h C0h 0 No mean 1 OFF 2 ON AUTO OFF 10h C1h 0 No mean 1 ...

Страница 39: ...HT SETTING SENSI NG LUX 02h B4h Current Illuminance read Read only HUMAN SENSING MODE 10h 75h 0 No mean 1 DISABLE 2 AUTO OFF 4 CUSTOM ON OF F 10h DDh 0 No mean 1 Off 2 On BACKLIGHT BACKL IGHT 10h C6h 0 dark 100 64h light ON OF F 10h DEh 0 No mean 1 Off 2 On VOLUME VOLUM E 10h C7h 0 whisper 100 64h loud ON OF F 10h DFh D0h 0 No mean 1 Off 2 On INPUT SELECT INPUT 10h D0h 0 No mean 1 VGA 2 RGB HV 3 D...

Страница 40: ...AUDIO INPUT 02h 2Eh 0 No mean 1 IN1 2 IN2 3 IN3 4 HDMI 6 OPTION 7 DPORT 8 DPORT2 9 DPORT3 10 0Ah HDMI2 VOLUME UP DOWN 00h 62h 0 whisper 100 64h loud MUTE 00h 8Dh 0 UNMUTE Set only 1 MUTE 2 UNMUTE SCREEN MUTE 10h B6h 0 No mean 1 SCREEN MUTE ON 2 SCREEN MUTE OFF MTS 02h 2Ch 0 No mean 1 Main 2 Sub 3 Main Sub This operation requires supported option TV tuner SOUND 02h 34h 0 No mean 1 Off 2 ON Same as ...

Страница 41: ...APTURE 02h 76h 0 OFF 1 CAPTURE Momentary SIGNAL INFORMATION 02h EAh 0 No mean 1 OFF 2 ON AUTO SETUP 00h 1Eh 0 No mean 1 Execute Momentary TV CHANNEL UP DOWN 00h 8Bh 0 No mean 1 UP 2 DOWN This operation requires supported option TV tuner SELECT TEMPERATURE SENSOR 02h 78h 0 No mean 1 SENSOR 1 2 SENSOR 2 3 SENSOR 3 TEMPERATURE SENSOR READOUT A TEMPERATURE 02h 79h Returned value is 2 s complement Refe...

Страница 42: ...iter CR 0Dh End of packet 2 The monitor returns with the current power status Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message Type is Command reply 1 2 31h 32h Message length is 18 bytes Message STX 02h Start of Message 0 2 30h 32h Reserved data ...

Страница 43: ... 43 137 Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 44: ...tion Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 32h and...

Страница 45: ... 45 137 Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 46: ...of Asset data area 2 0 32h 30h Read out data length is 32bytes Secondly set 20h Read data from the 32bytes offset point in the Asset data area Maximum readout length is 32bytes at a time ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Asset data to the controller Header Message Che...

Страница 47: ... 47 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 48: ...nd of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX 0 0 C 0 0 E 0 0 Data 0 Data 1 Data N ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate...

Страница 49: ... 49 137 CR 0Dh End of packet ...

Страница 50: ...f Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 4 STX C 3 1 1 YY MM DD WW HH MN DS ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a reply...

Страница 51: ...sday 0 5 30h 35h Friday 0 6 30h 36h Saturday HH Hours 0 0 30h 30h 0 1 7 31h 37h 23 17h MN Minutes 0 0 30h 30h 0 3 B 33h 42h 59 3Bh DS Daylight saving Summer time 0 0 30h 30h NO 0 1 30h 31h YES ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 52: ...gth Message STX 02h Start of Message C 2 1 2 43h 32h 31h 32h Date Time write command YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 30h 31h JANUARY 0 C 30h 43h DECEMBER DD Day 0 1 30h 31h 1 1 E 31h 45h 30 1Eh 1 F 31h 46h 31 1Fh WW weekdays 0 0 30h 30h SUNDAY 0 1 30h 31h MONDAY 0 2 30h 32h TUESDAY 0 3 30h 33h WEDNESDAY 0 4 30h 34h THURS...

Страница 53: ...rt of Message C 3 1 2 43h 33h 31h 32h Date Time write reply command ST Date Time Status command 0 0 30h 30h No error 0 1 30h 31h Error YY MM DD WW HH MN DS Date Time data YY Year offset 2000 0 0 30h 30h 2000 6 3 36h 33h 2099 99 63h MM Month 0 1 30h 31h JANUARY 0 C 30h 43h DECEMBER DD Day 0 1 30h 31h 1 1 E 31h 45h 30 1Eh 1 F 31h 46h 31 1Fh WW weekdays 0 0 30h 30h SUNDAY 0 1 30h 31h MONDAY 0 2 30h 3...

Страница 54: ... 54 137 Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 55: ...fer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 2 6 STX C 3 2 1 PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Moni...

Страница 56: ... 0 E 30h 45h Y Pb Pr2 0 F 30h 46h DPORT 1 0 31h 30h DPORT2 1 1 31h 31h HDMI 1 2 31h 32h HDMI2 8 0 38h 30h DPORT3 WD Week setting bit 0 MONDAY bit 1 TUESDAY bit 2 WEDNESDAY bit 3 THURSDAY bit 4 FRIDAY bit 5 SATURDAY bit 6 SUNDAY EX 0 1 30h 31h MONDAY 0 4 30h 34h TUESDAY 0 F 30h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyday bit 1 0 once 1 Ev...

Страница 57: ...0 EXT4 Extension 4 0 0 30h 30h On this monitor it is always 00 EXT5 Extension 5 0 0 30h 30h On this monitor it is always 00 EXT6 Extension 6 0 0 30h 30h On this monitor it is always 00 EXT7 Extension 7 0 0 30h 30h On this monitor it is always 00 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 58: ... Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Schedule to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 6 STX C 3 1 3 PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Mon...

Страница 59: ...IDEO 0 5 30h 35h S VIDEO 0 7 30h 30h No mean Works on last memory WD Week setting bit 0 MONDAY bit 1 TUESDAY bit 2 WEDNESDAY bit 3 THURSDAY bit 4 FRIDAY bit 5 SATURDAY bit 6 SUNDAY EX 0 1 30h 31h MONDAY 0 4 30h 34h TUESDAY 0 F 30h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyday bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable EX 0 1 30h 31...

Страница 60: ... PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33h 42h 59 3 C 33h 43h On timer isn t set OFF_HOUR Turn off time hour 0 0 30h 30h 00 1 7 31h 3...

Страница 61: ...0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h No mean works on last memory 0 1 30h 31h sRGB 0 3 30h 33h HiGHBRIGHT 0 4 30h 34h STANDARD 0 5 30h 34h CINEMA 0 D 30h 44h CUSTOM1 0 E 30h 45h CUSTOM2 Please select active picture mode on your system setting If you select inactive picture mode here the input change execution will be ignored EXT1 Extension1 0 0 30h 3...

Страница 62: ...essage C 3 2 2 43h 33h 32h 32h Schedule writes reply command ST Schedule Status command 0 0 30h 30h No error 0 1 30h 31h Error PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL P MODE EXT1 EXT2 EXT3 EXT4 EXT5 EXT6 EXT7 Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn o...

Страница 63: ...0 4 30h 34h Enable once P MODE Picture mode 0 0 30h 30h No mean works on last memory 0 1 30h 31h sRGB 0 3 30h 33h HIGHBRIGHT 0 4 30h 34h STANDARD 0 5 30h 34h CINEMA 0 D 30h 44h CUSTOM1 0 E 30h 45h CUSTOM2 EXT1 Extension1 0 0 30h 30h On this monitor it is always 00 EXT2 Extension 2 0 0 30h 30h On this monitor it is always 00 EXT3 Extension 3 0 0 30h 30h On this monitor it is always 00 EXT4 Extensio...

Страница 64: ...ble 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 4 The monitor replies a data for confirmation Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor...

Страница 65: ... 65 137 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 66: ... command PG ON HOURS ON MIN OFF HOURS OFF MIN INPUT WD FL Schedule data PG Program No 0 0 30h 30h Program No 1 0 6 30h 36h Program No 7 ON_HOUR Turn on time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h ON timer isn t set ON_MIN Turn on time minute 0 0 30h 30h 0 3 B 33h 42h 59 3 C 33h 43h On timer isn t set OFF_HOUR Turn off time hour 0 0 30h 30h 00 1 7 31h 37h 23 17h 1 8 31h 38h Off timer is...

Страница 67: ... Check code Delimiter SOH 0 0 Monitor ID B 1 8 STX C 3 1 4 ST PG ON HOUR ON MIN OFF HOUR OFF MIN INPUT WD FL ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 1 8 31h 38h Message length Message STX 02h Start of Mess...

Страница 68: ...0h 46h MONDAY TUESDAY WEDNESDAY and THURSDAY 7 F 37h 46h MONDAY to SUNDAY FL Option bit 0 0 once 1 Everyday bit 1 0 once 1 Every week bit 2 0 Disable 1 Enable When bit 0 and bit 1 are 1 it behaves as Everyday EX 0 1 30h 31h Disable Everyday 0 4 30h 34h Enable once ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End o...

Страница 69: ...C STX C 3 1 5 ST PG EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 0 C 30h 43h Message length Message STX 02h Start of Message C 3 1 5 43h 33h 31h 35h Enable Disable Schedule writes reply command ST Enable Dis...

Страница 70: ...h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message type is Command reply N N Message length Note The maximum data length that can be written to the monitor at a time is 32bytes Ex The byte data 20h is encoded as ASCII characters 2 and 0 34h and 30h Message STX 0...

Страница 71: ...44h 30h D0 PROOF OF PLAY buffer reduction E 0 45h 30h E0 System error ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 72: ...code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the serial No data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 6 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monito...

Страница 73: ...lculation Delimiter CR 0Dh End of packet 2 The monitor replies the model name data to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B N N STX C 3 1 7 Data 0 Data 1 Data n ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h ...

Страница 74: ... code Delimiter SOH 0 MonitorID 0 A 1 0 STX C 2 1 D EN P1 P2 P3 P4 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID of which you want to change a setting Ex If Monitor ID is 1 specify A 0 30h Message sender is the controller A 41h Message type is Command 1 0 31h 30h Message length Message STX 02h Start of Message C 2 1 D 43h 32h 31h 44h Security Lock Contr...

Страница 75: ...is set to A the replying Monitor ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length Message STX 02h Start of Message C 3 1 D 43h 33h 31h 44h Security Lock Control reply command ST EN Lock condition result data ST Status 0 0 30h 30h No error 0 1 30h 31h Error EN Enable Disable Current condition 0 0 30h 30h Disable 0 1 30h 31h Enable ETX 03h End of Message Check code BCC Block Ch...

Страница 76: ...ock Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 2 STX C 3 2 C MajorCH MinorCH ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byt...

Страница 77: ... Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 2 STX C 3 2 D MajorCH MinorCH ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor I...

Страница 78: ... Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Date Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 2 0 STX C B 0 1 0 0 ST BM BD1 BD BT1 BT2 EM ED1 ED2 ET1 ET2 TD ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID...

Страница 79: ...h 31h SECOND 02h 30h 32h THIRD 03h 30h 33h FOUR 04h 30h 34h LAST 05h 30h 35h ED2 END DAY2 SUNDAY 01h 30h 31h MONDAY 02h 30h 32h TUESDAY 03h 30h 33h WEDNESDAY 04h 30h 34h THURSDAY 05h 30h 35h FRIDAY 06h 30h 36h SATURDAY 07h 30h 37h ET1 END TIME1 00h 30h 30h 23 32h 33h ET2 END TIME2 00h 30h 30h 59 35h 39h TD TIME DIFFERENCE 01 00 00h 30h 30h 00 30 01h 30h 31h 00 30 02h 30h 32h 01 00 03h 30h 33h ETX ...

Страница 80: ...Setting Command 0 1 30h 31h Write BM BEGIN MONTH JANUARY DECEMBER 01h 30h 31h 12h 31h 32h BD1 BEGIN DAY1 FIRST 01h 30h 31h SECOND 02h 30h 32h THIRD 03h 30h 33h FOUR 04h 30h 34h LAST 05h 30h 35h BD2 BEGIN DAY2 SUNDAY 01h 30h 31h MONDAY 02h 30h 32h TUESDAY 03h 30h 33h WEDNESDAY 04h 30h 34h THURSDAY 05h 30h 35h FRIDAY 06h 30h 36h SATURDAY 07h 30h 37h BT1 BEGIN TIME1 00h 30h 30h 23 32h 33h BT2 BEGIN T...

Страница 81: ...ader SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A replying monitor s ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length 10bytes Message STX 02h Start of Message C B 0 1 43h 42h 30h 31h Daylight Saving Setting Command 0 1 30h 31h Write ST Error Status No Error 00h 30h 30h E...

Страница 82: ...ware2 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a firmware version to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 1 8 STX C B 0 2 ST TY MV PP BV1 BV2 BV3 BR1 BR2 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message rec...

Страница 83: ...sion2 00h 30h 30h 09h 30h 39h BV3 Minor Basic Version3 00h 30h 30h 09h 30h 39h BR1 Branch Version1 A 41h 34h 31h Z 5Ah 35h 41h BR2 Branch Version1 A 41h 34h 31h Z 5Ah 35h 41h Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 84: ...e ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies receipt result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 1 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ...

Страница 85: ... 85 137 Delimiter CR 0Dh End of packet ...

Страница 86: ...plete ST Error Status No Error 00h 30h 30h Error 01h 30h 31h MON DETECTED MONITORS 01h 30h 31h 64h 36h 34h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The controller replies to the monitor Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 2 ST ETX BCC CR Header SOH 01h Sta...

Страница 87: ... 87 137 Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 88: ... code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 A 0 3 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set...

Страница 89: ...eck Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Input Name to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B LN H LN L STX C B 0 4 0 0 Data 0 Data 1 Data 2 Data n ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID ...

Страница 90: ... 90 137 Delimiter CR 0Dh End of packet ...

Страница 91: ...x 7 Ex The byte data 20h is encoded as ASCII characters 2 and 0 32h and 30h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 0 0 1 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0...

Страница 92: ... 92 137 Delimiter CR 0Dh End of packet ...

Страница 93: ... ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 0 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex Whe...

Страница 94: ... 94 137 Delimiter CR 0Dh End of packet ...

Страница 95: ... 30h 33h Auto Tile Matrix Command 0 1 30h 31h Execution HM HORIZONTAL MONITORS 01h 30h 31h 10h 31h 30h VM VERTICAL MONITORS 01h 30h 31h 10h 31h 30h PID PETTERN ID 01h 30h 31h Fixed SEL CURRENT INPUT SELECT VGA 01h 30h 31h DVI 03h 30h 33h VIDEO 05h 30h 35h S VIDEO 07h 30h 37h Y Pb Pr 0Ch 30h 43h OPTION 0Dh 30h 44h Y Pb Pr2 0Eh 30h 45h DPORT 0Fh 30h 46h DPORT2 10h 31h 30h HDMI 11h 31h 31h HDMI2 12h ...

Страница 96: ...e type is Command reply 0 A 30h 41h Message length 10bytes Message STX 02h Start of Message C B 0 3 43h 42h 30h 33h Auto Tile Matrix Command 0 1 30h 31h Execution ST Error Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 97: ...ify ST Error Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The controller replies to the monitor Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiv...

Страница 98: ... 98 137 Delimiter CR 0Dh End of packet ...

Страница 99: ... End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies H V Monitors to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 E STX C B 0 3 0 4 ST HM VM ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a repl...

Страница 100: ... 100 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 101: ...30h 30h 41h VM V MONITORS 00h 0Ah 30h 30h 30h 41h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 5 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is t...

Страница 102: ... 102 137 Delimiter CR 0Dh End of packet ...

Страница 103: ...0h 36h Off ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies receipt result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 3 0 6 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying...

Страница 104: ... 104 137 Delimiter CR 0Dh End of packet ...

Страница 105: ... Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Power Save Mode to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 0 MODE ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID ...

Страница 106: ... 106 137 Delimiter CR 0Dh End of packet ...

Страница 107: ...ER SAVE 01h 30h 31h AUTO STANDBY 02h 30h 32h POWER SAVE OFF ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 1 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message rec...

Страница 108: ... 108 137 Delimiter CR 0Dh End of packet ...

Страница 109: ...ge Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 2 TIME ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When t...

Страница 110: ...ec 00h 30h 30h 78h 37h 38h 1 5dec 120 600sec ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 8 STX C B 0 B 0 3 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the co...

Страница 111: ... 111 137 Delimiter CR 0Dh End of packet ...

Страница 112: ...age Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Time to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 4 TIME ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When ...

Страница 113: ...h 30h 30h 78h 37h 38h 1 5dec 120 600sec ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 B 0 5 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the control...

Страница 114: ... 114 137 Delimiter CR 0Dh End of packet ...

Страница 115: ...ck Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Setting Copy to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 1 0 STX C B 0 9 0 0 T4 T3 T2 T1 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is ...

Страница 116: ...CTURE is OFF 0 Bit2 ADJUST is ON 1 Bit3 AUDIO is ON 1 Step 1 Put above bit in following order Bit3 Bit2 Bit1 Bit0 Value 1100 Step 2 Write the value of Step 1 by a hexadecimal number Value 0Ch Step 3 Encode the value of Step 2 to ASCII characters Value 0 and C 30h and 43h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0D...

Страница 117: ...h T1 Setting Copy Target 4 Bit12 Bit15 T2 Setting Copy Target 3 Bit8 Bit11 T3 Setting Copy Target 2 Bit4 Bit7 T4 Setting Copy Target 1 Bit0 Bit3 Bit0 ALL INPUT Bit1 PICTURE Bit2 ADJUST Bit3 AUDIO Bit4 SCHEDULE Bit5 PIP Bit6 OSD Bit7 MULTI DISP Bit8 PROTECT Bit9 EXT CTRL Bit10 ADVANCED Bit11 ADVANCED2 Bit12 HTTP Bit13 Reserve Bit14 Reserve Bit15 Reserve Ex Setting the following value for T4 Bit0 AL...

Страница 118: ...ate a replying Monitor ID Ex When this byte is set to A replying monitor s ID is 1 B 42h Message type is Command reply 0 A 30h 41h Message length 10byte Message STX 02h Start of Message C B 0 9 43h 42h 30h 39h Setting Copy Reply 0 1 30h 30h Target Write ST Status No Error 00h 30h 30h Error 01h 30h 31h ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a ...

Страница 119: ... ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 9 0 2 ST ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monito...

Страница 120: ... 120 137 Delimiter CR 0Dh End of packet ...

Страница 121: ...h Enable Read ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies Security Enable to the controller Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 C 0 2 EN ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ...

Страница 122: ... 122 137 Delimiter CR 0Dh End of packet ...

Страница 123: ...Enable Write ENA Enable Disable 00h 30h 30h Disable 01h 30h 31h Enable 0 0 30h 30h Reserved PWD1 PWD8 Password data ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies a written in result Header Message Check code Delimiter SOH 0 0 Monitor ID B 0 A STX C B 0 C 0 1 ST ETX BCC CR Header ...

Страница 124: ... 124 137 Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 125: ...age Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies MAC Address to the controller Header SOH 01h Start of Header 0 30h Reserved 0 30h Message receiver is the controller Monitor ID Indicate a replying Monitor ID Ex When this byte is set to A the replying Monitor ID is 1 B 42h Message Type is Command reply...

Страница 126: ... 126 137 In the case of IPv6 n 7 ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 127: ... Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result of Start to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 2 2 STX C B 0 6 0 0 Data 0 Data 1 Data 2 Data 12 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID from which you want t...

Страница 128: ... 128 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...

Страница 129: ... to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result of Stop to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 2 2 STX C B 0 6 0 1 Data 0 Data 1 Data 2 Data 12 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID from which you want to get status Ex If Monitor ID is 1 spec...

Страница 130: ... 130 137 Delimiter CR 0Dh End of packet ...

Страница 131: ...Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the current log of Proof of Play to the controller Header Message Check code Delimiter SOH 0 Monitor ID 0 B 2 2 STX C B 0 6 0 2 Data 0 Data 1 Data 2 Data 12 ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID from which you want to get sta...

Страница 132: ...No mean 0 1 IN1 0 2 IN2 0 3 IN3 0 4 HDMI 0 6 OPTION 0 7 DPORT 0 8 DPORT2 0 9 DPORT3 0 A HDMI2 Data 6 Check with or without Audio 0 0 30h 30h Audio in 0 1 30h 31h No Audio in 0 2 30h 32h N A Data 7 Check status Picture 0 0 30h 30h Normal Picture 0 1 30h 31h No Picture Data 8 Check status Audio 0 0 30h 30h Normal Audio 0 1 30h 31h No Audio Data 9 Data 10 hour h h h h 0 65535 0000h FFFFh Data 11 min ...

Страница 133: ... 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the result the total number of Proof of Play data Header Message Check code Delimiter SOH 0 Monitor ID 0 B 0 C STX C B 0 6 0 3 TN H TH L ETX BCC CR Header SOH 01h Start of Header 0 30h Reserved Monitor ID Specify the Monitor ID from whic...

Страница 134: ... 134 137 Delimiter CR 0Dh End of packet ...

Страница 135: ... log command BNS H Block Number of Start High byte BNS L Block Number of Start Low byte BNE H Block Number of Stop High byte BNE L Block Number of Stop Low byte ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet 2 The monitor replies the number to number log of Proof of Play to the controller Header Messag...

Страница 136: ...length is 38 bytes Message STX 02h Start of Message C B 0 6 Proof of Play reply command 0 4 30h 34h Get Proof of Play Number to Number log command Data 0 Data 12 Log Data of Proof of Play of STOP 26byte Same as Get Proof of Play Current Refer to Get Proof of Play Current ETX 03h End of Message Check code BCC Block Check Code Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0D...

Страница 137: ...d This document provides the technical information for users NEC Display Solutions Ltd reserves the right to change or modify the information contained herein without notice NEC Display Solutions Ltd makes no warranty for the use of its products and bears no responsibility for any errors or omissions which may appear in this document ...

Отзывы: