(23/137)
IV. Control Commands
6. Typical procedure example
The following is a sample of procedures to control the monitor, these are examples of "Get parameter",
"Set parameter" and "Save current settings".
6.1. How to change the
“
Backlight
”
setting.
Step 1. The controller requests the Monitor to reply with the current brightness setting and capability
to support this operation. (Get parameter)
Header
Message
Check code
Delimiter
SOH-'0'-Monitor ID-
'0'-'C'-'0'-'6'
STX-'0'-'0'-'1'-'0'-ETX
BCC
CR
Header
SOH (01h): Start of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID from which you want to get a value.
Ex.) If Monitor ID is '1', specify 'A'.
'0' (30h): Message sender is the controller.
'C' (43h): Message type is "Get parameter command".
'0'-'6' (30h, 36h): Message length is 6 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the OP code page 0).
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Delimiter
CR (0Dh): End of packet
Step 2. The monitor replies with current Backlight setting and capability to support this operation.
Header
SOH (01h): Start of Header
'0' (30h): Reserved
'0' (30h): Message receiver is the controller.
Monitor ID: Indicate a replying Monitor ID.
Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get parameter reply".
'1'-'2' (31h, 32h): Message length is 18 bytes.
Message
STX (02h): Start of Message
'0'-'0' (30h, 30h): Result code. No error.
'0'-'0' (30h, 30h): Operation code page number is 0.
'1'-'0' (31h, 30h): Operation code is 10h (in the page 0).
'0'-'0' (30h, 30h): This operation is "Set parameter" type.
'0'-'0'-'6'-'4' (30h, 30h, 36h, 34h): Backlight max value is 100(0064h).
'0'-'0'-'3'-'2' (30h, 30h, 33h, 32h): Current Backlight setting is 50(0032h) .
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5
“
Check code
”
for a BCC calculation.
Header
Message
Check code
Delimiter
SOH-'0'-'0'-Monitor ID-
'D'-'1'-'2'
STX-'0'-'0'-'0'-'0'-'1'-'0'-'0'-'0'
-'0'-'0'-'6'-'4'-'0'-'0'-'3'-'2'-ETX
BCC
CR
Содержание LCD Monitor
Страница 6: ... 6 137 Please refer Controlling the LCD monitor via LAN control on User s manual ...
Страница 14: ... 14 137 4 4 Delimiter Packet delimiter code ASCII CR 0Dh Header Message Check code Delimiter ...
Страница 17: ... 17 137 18th byte ETX End of Message ASCII ETX 03h ...
Страница 47: ... 47 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 49: ... 49 137 CR 0Dh End of packet ...
Страница 85: ... 85 137 Delimiter CR 0Dh End of packet ...
Страница 90: ... 90 137 Delimiter CR 0Dh End of packet ...
Страница 92: ... 92 137 Delimiter CR 0Dh End of packet ...
Страница 94: ... 94 137 Delimiter CR 0Dh End of packet ...
Страница 98: ... 98 137 Delimiter CR 0Dh End of packet ...
Страница 100: ... 100 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 102: ... 102 137 Delimiter CR 0Dh End of packet ...
Страница 104: ... 104 137 Delimiter CR 0Dh End of packet ...
Страница 106: ... 106 137 Delimiter CR 0Dh End of packet ...
Страница 108: ... 108 137 Delimiter CR 0Dh End of packet ...
Страница 111: ... 111 137 Delimiter CR 0Dh End of packet ...
Страница 114: ... 114 137 Delimiter CR 0Dh End of packet ...
Страница 120: ... 120 137 Delimiter CR 0Dh End of packet ...
Страница 122: ... 122 137 Delimiter CR 0Dh End of packet ...
Страница 128: ... 128 137 Refer to the section 4 5 Check code for a BCC calculation Delimiter CR 0Dh End of packet ...
Страница 130: ... 130 137 Delimiter CR 0Dh End of packet ...
Страница 134: ... 134 137 Delimiter CR 0Dh End of packet ...