Step 1
Set the intervals IntraMail will wait between incomplete non-pager Message Noti
fi
cation
callouts.
1.1
8004 - IntraMail System Options
Wait Between Non-Pager Callout Attempts
- Set the minimum time (
1-255
minutes) between non-pager Message Noti
fi
cation callouts in
which the destination answers, says “Hello,” dials 1 to acknowledge and then enters the
wrong security code.
✔
The default for this option is
20
minutes.
1.2
8004 - IntraMail System Options
Wait Between Busy Non-Pager Callout Attempts
page 215.
- Set how long IntraMail will wait (
1-255
minutes), after it dials a busy non-pager callout
destination, before retrying the callout number.
✔
The default for this option is
15
minutes.
1.3
8004 - IntraMail System Options
Wait Between RNA Non-Pager Callout Attempts
1.4
- Set how long IntraMail will wait (
1-255
minutes), after it dials an unanswered non-pager
callout destination, before retrying the callout number. The default setting for this option is
30 minutes.
- There are three types of unanswered non-pager callouts:
- If the callout rings the destination longer than the
8004-Wait for Answer Non-Pager
Callout Attempts
.
- If the destination answers, says “Hello” (or the system detects answer supervision)
and then hangs up without dialing 1 to log onto their mailbox. This typically hap-
pens if someone unfamiliar with noti
fi
cation answers the callout, or if the callout is
picked up by an answering machine.
- If the destination answers and then hangs up without saying “Hello.” This typically
happens if someone unfamiliar with the noti
fi
cation answers the callout (like the
above example), or if the call is picked up by an answering machine which insuf
fi
-
cient outgoing message volume.
✔
The default for this option is
30
minutes.
Step 2
Set how IntraMail determines when a non-pager callout rings without being answered.
2.1
8004 - IntraMail System Options
Wait for Answer Non-Pager Callout Attempts
- If a non-pager callout rings the destination longer than this option (
1-99
rings), IntraMail
marks the call as unanswered (Ring No Answer) and hangs up.
✔
The default for this option is
5
rings.
Содержание IntraMail 4
Страница 10: ...Table of Contents viii Table of Contents IntraMail System Guide...
Страница 20: ...Programming Application Examples 10 Chapter 1 Quick Setup IntraMail System Guide...
Страница 198: ...Volume Control 188 Chapter 2 Features IntraMail System Guide...
Страница 264: ...8000 Voice Mail 8008 IntraMail Dial Action Tables 254 Chapter 3 Programming IntraMail System Guide...