CHAPTER 3 INSTALLATION
User’s Manual U16290EJ1V0UM
22
3.3 Power Supply Voltage Setting of Target Interface
The IE system allows emulation at the same voltage level as that of the target system.
When the target system is not connected, the system automatically operates on the internal power supply (3 V) of
the emulator. When debugging at the same voltage level as that of the target system, supply the TM1 terminal pin of
the IE-789835-NS-EM1 with the same voltage as that of the target system (the same applies when the voltage is 3
V).
For how to select the operating power supply, refer to the
ID78K Series Ver. 2.30 or Later Operation (Windows
Based) User’s Manual (U15185E)
.
•
Maximum current consumption of TM1 3 V: Approximately 100 mA
Table 3-3. Power Supply Settings of Target Interface
Integrated Debugger (ID78K0S-NS)
Power Supply of Target Interface
Selected Operating Power Supply
When connecting target system
1.8 to 3.6 V
Target
When not connecting target system
3 V
Internal
Figure 3-4. Connecting TM1 and Power Supply Voltage of Target System
IE-789835-NS-EM1
Target system
V
DD
GND
Power supply voltage of
target system
Emulation
probe
USER VDD
LED1
CN1
LowVolt GND
TM1
Caution
Before connecting TM1 on the board and the power supply voltage of the target system, turn
off the power to the IE-78K0S-NS or IE-78K0S-NS-A.
Remark
The V
DD
pin of the target system is exclusively used for the control of LED1 that monitors whether the
power supply of the target system is connected in the IE-789835-NS-EM1.