English
- 86
Replace the power unit 2 (slave).
Use the screws you have removed to secure the power unit.
Tightening torque: 3 ± 0.5 kgf•cm
Replace the power unit 1 (master).
Use the screws you have removed to secure the power unit.
Tightening torque: 3 ± 0.5 kgf•cm
Remove the two screws securing the power unit.
Use a Phillips screwdriver (No. 2).
Remove the two screws securing the power unit.
Use a Phillips screwdriver (No. 2).
The FE series power supply unit is only on the bottom side.
Replacing the receiving card
Remove the receiving card from the hub board.
Remove the four screws securing the receiving card, and then remove the receiving card from the hub board.
Install the receiving card so that the
arrow is orientated to the left.
Hub board
Receiving card (slave)
Receiving card (master)
Remove the four screws.
Use a Phillips screwdriver (No. 1).
Tightening torque: 3 ± 0.5 kgf•cm
The FE series receiving card is (master) only.
Содержание FA Series
Страница 17: ...English 15 8 x 8 frame set...
Страница 29: ...English 27 8 x 8 frame set Cabinet Power bar Mounting bar Mounting bar Positions for Cabinet hanger pins...
Страница 82: ...English 80 9 The adjustment is complete when the following screen is displayed Click Close to finish...
Страница 105: ...English 103 The monitoring screens appear like below...
Страница 130: ...English 128 LED FA025i2 LED FE025i2 608 49 342 Rear 4 x M8 18 5 24 24 44 44 520 294 Unit mm...