List of Windows Event Log
Installation Guide (Windows Server 2016)
100
Chapter 3 Appendix
ID
Source
Level
Message (Description)
Timing when an event is logged
Action
Windows Server 2016 ”System Log”
7023
Service Control Manager
Error
The Data Sharing Service service terminated with the following
error: %%3239247874
* The message may not be displayed correctly as follows, but there
is no problem.
The description for Event ID 7023 from source Service Control
Manager cannot be found. Either the component that raises this
event is not installed on your local computer or the installation is
corrupted. You can install or repair the component on the local
computer.
If the event originated on another computer, the display information
had to be saved with the event.
The following information was included with the event:
Data Sharing Service
%%3239247874
The locale specific resource for the desired message is not present.
When running an OS for the first time or
rebooting it, or while the system is in use
This event does not affect system operation.
7024
Service Control
Manager
Error
The Intel® Ethernet Thermal Sensor Monitor Service service
terminated with the following service-specific error:
The operation completed successfully."
When starting system, or applying Standard
Program Package
This event does not affect system operation.
7030
Service Control Manager
Error
The Printer Extensions and Notifications service is marked as an
interactive service. However, the system is configured to not allow
interactive services. This service may not function properly.
When running an OS for the first time
This event does not affect system operation if it is recorded only on
the first startup and not recorded repeatedly.
10010
Microsoft-Windows-
DistributedCOM
Error
The server {XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX} did
not register with DCOM within the required timeout.
When running an OS for the first time or
rebooting it
Refer to the following website.
https://support.microsoft.com/ja-jp/help/956479
(Japanese)
10317
Microsoft-Windows-NDIS
Error
Miniport Microsoft Network Adapter Multiplexor Driver,
{xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx}, had event Network
Interface deleted while PNP Device still exists. Note that this event is
provided for informational purpose and might not be an error always
(Eg: In case of vSwitch which was recently un-installed or a LBFO
team was removed)
When removing a team
This event does not affect system operation.