- 52 -
B) Errata Information
■
Errata Information for Express5800/R120h-1M User’s Guide
The following table covers corrections for User’s Guide.
Please read the following information and use it as reference.
Error
Correct
Chapter 2 Preparations
1.10.7 Memory Function
(1) Memory Mirroring
Function
From System Utility, set "System
Configuration > BIOS/Platform
Configuration (RBSU) > System
Options > Memory Operations > Advanced
Memory Protection" to "Mirrored Memory
with Advanced ECC Support".
From System Utility, set "System
Configuration > BIOS/Platform Configuration
(RBSU) > Memory Options > Advanced
Memory Protection" to "Mirrored Memory
with Advanced ECC Support".
Chapter 2 Preparations
1.10.7 Memory Function
(2) Memory Sparing
Function
From System Utility, set "System
Configuration > BIOS/Platform
Configuration (RBSU) >System Options >
Memory Oprations > Advanced Memory
Protection" to "Online Spare with Advanced
ECC Support".
From System Utility, set "System
Configuration > BIOS/Platform Configuration
(RBSU) > Memory Options > Advanced
Memory Protection" to "Online Spare with
Advanced ECC Support".
Chapter 2 Preparations
1.10.7 Memory Function
(3) Fault tolerant
memory function
(ADDDC)
From the System Utilities, select "System
Configuration > BIOS/Platform
Configuration (RBSU) > System Options >
Memory Operations to set Advanced
Memory Protection to Fault Tolerant
Memory (ADDDC)".
From the System Utilities, select "System
Configuration > BIOS/Platform Configuration
(RBSU) > Memory Options to set Advanced
Memory Protection to Fault Tolerant Memory
(ADDDC)".
Chapter 2 Preparations
1.25.1 Notes on Building
RAID System
If the optional RAID Controller N8103-
189/192/195 is used, the RAID System
cannot be built in
RAID5/RAID6/RAID50/RAID60.
RAID level
The minimum number of
hard disk drives required
to set up a
RAID System
N8103-
189/192/195
N8103-
190/191/193
/194/201
RAID 0
1
1
RAID 1
2
2
RAID 5
3
RAID 6
3
RAID 10
4
4
RAID 50
6
RAID 60
6
If the optional RAID Controller N8103-
189/192/195 is used, the RAID System
cannot be built in
RAID6/RAID50/RAID60.
RAID level
The minimum number of
hard disk drives required
to set up a
RAID System
N8103-
189/192/195
N8103-
190/191/193
/194/201
RAID 0
1
1
RAID 1
2
2
RAID 5
3
3
RAID 6
4
RAID 10
4
4
RAID 50
6
RAID 60
8
Chapter 3 Setup
2.4 Cases that Require
Configuration
>Memory
>Use memory RAS
feature
Set System Configuration > BIOS/Platform
Configuration (RBSU) > System Options >
Memory Oprations - Advanced Memory
Protection
Set System Configuration > BIOS/Platform
Configuration (RBSU) > Memory Options -
Advanced Memory Protection
OS supported
VMware ESXi™ 6.7 Update1 or later
VMware ESXi™ 6.7 Update2 or later
On-board CPU
Xeon Gold 6234 Processor (3.40 GHz,
8C/16T, TDP 130W, DDR4 2933 1TB)
Xeon Gold 6234 Processor (3.30 GHz,
8C/16T, TDP 130W, DDR4 2933 1TB)
Содержание Express5800/R120h-1M
Страница 2: ...2...