background image

- 46 - 

 

(6)  Check  the  values  of  Serial  Number  and  Product  ID  by  selecting  the  menu  of  the  System  Utilities:  System 

Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced Service Options. 

 
(7) If the values of Serial Number and Product ID are satisfactory, go to step 14. 
 
(8) If the values are unexpected or lost, select the menu of the System Utilities: System Configuration > BIOS/Platform 

Configuration (RBSU) > System Default Options. 

 
(9) Select the Restore Default Manufacturing Settings option. 
 
(10) Select this option: Yes, restore the default settings. 
 
(11) The server restarts automatically and the POST screen appears. 
 
(12) Press the F9 key to enter the System Utilities. 
 
(13) Set the proper Serial Number and Product ID (indicated on the pull-out tab of the server) via the menu of the System 

Utilities: System Configuration > BIOS/Platform Configuration (RBSU) > Advanced Options > Advanced Service 
Options. 

 

Important

Product ID is the model number like "N8100-2557F". Product ID is not PID. 

 
(14) If the RBSU settings have been changed from the defaults, check and configure the new values. 
 

● Note on using UPS 

 When connecting UPS to a serial port, set the items to “Disabled” in the following settings as below: 

(1) System Configuration > BIOS/Platform Configuration (RBSU) > System Options > Serial Port Options > BIOS 

Serial Console and EMS > BIOS Serial Console Port 

 [Disabled] 

 
(2) System Configuration > BMC Configuration Utility > Setting Options > Serial CLI Status 

 [Disabled] 

 

 If the N8181-160 (power supply unit [800W/Platinum]) is used by redundant configuration, change the following settings: 

 

System Configuration > BIOS/Platform Configuration (RBSU) > Power and Performance Options >Advanced Power 
Options > Redundant Power Supply Mode

  →

 [High Efficiency Mode (Auto)] 

 

 The customer set as High Efficiency Mode (Odd Supply Standby) or High Efficiency Mode (Even Supply Standby)  

is unnecessary for change above-mentioned. 

 

●Note on using N8116-51 SAS Expander Card 

When updating firmware from this Starter Pack (Ver S8.10-009.01), please do NOT apply the following firmware update 
module (Ver.5.08). 
 

[Package Name] 

Supplement Upate / Online ROM Flash Component for Linux (x64) ? HPE 12Gb/s SAS  Expander Firmware for 
HPE Smart Array Controllers and HPE HBA Controllers 
 (firmware-smartarray2de15b6882-5.08-1.1x86_64) 

 
Please check the following Starter Pack Version S8.10-009.01 public page for detailed application procedures. 
[Starter Pack Version S8.10-009.01] 

https://www.58support.nec.co.jp/global/download/

 > 

-> Document & Software 

-> Rack 

 -> (Select your server model) 

Содержание Express5800/R120h-1M

Страница 1: ...ter Pack Starter Pack Web Web S8 10 007 01 https www support nec co jp NEC S8 10 007 VMware ESXi VMware ESXi Web Web 1 Agentless Management Service iLO Channel Interface Driver https www support nec c...

Страница 2: ...2...

Страница 3: ...3 2 ROM Submit Fail For Form Question Submit Fail For Form Question OK Serial Number Product ID RSOD Red Screen of Death OS RSOD OFF ON RSOD OFF ON...

Страница 4: ...nfiguration Lock SCL 1 SCL 2 SCL SCL SCL OS SCL SCL 3 SCL SCL 4 RBSU Halt on Server Configuration Lock failure detection SCL OS SCL RBSU DIMM PCI RESTful RBSU iLO5 2 40 RESTful RBSU RBSU Backup and Re...

Страница 5: ...Minimum Processor Idle Power Core C State No C states 3 System Configuration BIOS Platform Configuration RBSU Power and Performance Options Minimum Processor Idle Power Package C State No Package Sta...

Страница 6: ...CIe Device Configuration RAID RAID RAID HDD SSD BIOS Platform configuration RBSU PCIe Device Configuration N8103 189 N8103 190 N8103 191 N8103 192 N8103 193 N8103 194 N8103 195 N8103 196 N8103 197 N81...

Страница 7: ...7 3 Extended Memory Test ROM v2 36 07 16 2020 Extended Memory Test Disabled System Configuration BIOS Platform Configuration RBSU Memory Options Extended Memory Test...

Страница 8: ...urity Access Settings Update Service Downgrade Policy Permanently disallow downgrades Permanently disallow downgrades iLO Permanently disallow downgrades iLO Set to factory defaults iLO Permanently di...

Страница 9: ...ut Starter Pack Standard Program Package RAID iLO iLO iLO 5 1 45 iLO SNTP iLO iLO iLO Web SNTP iLO SNTP iLO 5 iLO Web UUID POST Power On Self Test iLO iLO Web Information Overview UUID UUID iLO Web iL...

Страница 10: ...etwork Adpters Adapter Network Ports IPv6 Address IPv6 vEthernet IPv6 OS iLO Web iLO 5 2 31 iLO Web Information Network Physical Network Adapters OS OS iLO Web Device Inventory SAS N8116 51 iLO 5 2 31...

Страница 11: ...rive status change has been detected Current status is 3 Location ot 12 Controller Slot 12 If the physical drive status is failed 3 predictiveFailure 4 Rapid Setup iLO5 2 71 2 72 Smart SW RAID POST F1...

Страница 12: ...ment Service AMS iLO Web System Information Storage Network Agentless Management Service AMS Windows Windows Agentless Management Service Red Hat Enterprise Linux 7 x 8 x systemctl restart smad system...

Страница 13: ...Service AMS 1 43 0 0 AMS Starter Pack Starter Pack Version S8 10 006 03 AMS 1 40 0 0 Starter Pack Version S8 10 006 03 AMS Starter Pack Web Agentless Management Service AMS 1 40 0 0 1 AMS net stop ams...

Страница 14: ...GBASE T LOM 2ch N8104 177 25GBASE LOM SFP28 2ch N8104 182 10GBASE T 2ch N8104 183 10GBASE T 2ch N8104 185 10GBASE SFP 2ch N8104 187 25GBASE SFP28 2ch PCI to PCI PCI a LAN b LAN c IP DNS DNS d IP IP DN...

Страница 15: ...ows 1 ESMPRO ServerManager https www support nec co jp View aspx id 9010103524 2 ESMPRO ServerManager Ver 6 Windows 2 ESMPRO ServerManager iLO MG iLO iLO Version 2 10 ilo_jp mtb Version 1 4 0 iml_jp m...

Страница 16: ...r iLO MG Windows 3 1 5 3 2 4 iLO SNMP Trap VMware ESXi ESXi VMware vSphere Heartbeat Lost Device I O Module n LOM_Link_P n Heartbeat Lost Assert Device I O Module n NIC_Link_P n Heartbeat Lost Assert...

Страница 17: ...ities System Configuration RBSU Server Security Trusted Platform Module Options Current TPM Type TPM Mode Switch Operation RAID VMware ESXi N8103 189 190 191 192 193 194 195 196 201 237 238 RAID N8103...

Страница 18: ...18 5 BMC Configuration Utility BMC Configuration Utility 1 2 Memory Initialization Start POST Serial Number Product ID 1 BMC Configuration Utility iLO Warning 2 OK 3 Warning Warning 1...

Страница 19: ...ervice Options Serial Number Product ID 7 Serial Number Product ID 14 8 Serial Number Product ID System Configuration BIOS Platform Configuration RBSU System Default Options 9 Restore Default Manufact...

Страница 20: ...Efficiency Mode Auto High Efficiency Mode Odd Supply Standby High Efficiency Mode Even Supply Standby N8116 51 SAS Starter Pack Version S8 10 009 01 N8116 51 SAS Ver 5 08 Supplement Update Online ROM...

Страница 21: ...SD SD SD BIOS Platform configuration RBSU System Options USB Options Internal SD Card Slot Disabled N8104 173 177 FCoE FCoE FibreChannel over Ethernet NEC N8104 173 LOM N8104 177 Family Firmware Versi...

Страница 22: ...10 WDT IPMI IPMI IPMI Watchdog Timer Timeout 1 10 Minutes 15 Minutes 20 Minutes 30 Minutes IPMI Watchdog Timer Action 1 Power Cycle Power Down Warm Boot 1 ROM Version 2 54 2 Memory Options System Conf...

Страница 23: ...ency Zero Latency Optimized for Throughput Optimized for Latency Zero Latency IODC Configuration Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow InvItoM Hybrid AllocFlow Enable for Remote...

Страница 24: ...Ie Bifurcation Options System Configuration BIOS Platform Configuration RBSU PCIe Devices Configuration Advanced PCIe Configuration PCIe Bifurcation Options PCIe Bifurcation Options PCIe Slot XX Bifur...

Страница 25: ...uration Optimal Cooling Increased Cooling Maximum Cooling Enhanced CPU Cooling Optimal Cooling Increased Cooling Increased Cooling Maximum Cooling Enhanced CPU Cooling 8 Advanced Debug Options System...

Страница 26: ...ory Protection Fault Tlerant Memory ADDDC System Configuration BIOS Platform Configuration RBSU Memory Options Advanced Memory Protection Fault Tolerant Memory ADDDC 2 1 25 1 RAID RAID N8103 189 192 1...

Страница 27: ...ns Advanced Memory Protection Fault Tlerant Memory ADDDC System Configuration BIOS Platform Configuration RBSU Memory Options Advanced Memory Protection Fault Tlerant Memory ADDDC 2 1 32 1 RAID RAID N...

Страница 28: ...ystem Configuration BIOS Platform Configuration RBSU System Options Memory Oprations Persistent Memory Options Persistent Memory Options System Configuration BIOS Platform Configuration RBSU Memory Op...

Страница 29: ...PU 2CPU CPU1 DIMM 1 2 3 4 5 6 7 8 9 10 11 12 DIMM 1 1 DIMM 2 1 2 DIMM 3 1 2 3 DIMM 4 4 3 1 2 DIMM 5 5 4 1 2 3 DIMM 6 6 5 4 1 2 3 DIMM 7 6 5 4 7 1 2 3 DIMM 8 4 8 3 7 5 1 6 2 DIMM 9 6 5 4 7 1 8 2 9 3 DI...

Страница 30: ...DIMM16 8 16 6 14 10 2 12 4 7 15 5 13 9 1 11 3 DIMM17 8 16 6 14 10 2 12 4 11 9 7 13 1 15 3 17 5 DIMM18 12 10 8 14 2 16 4 18 6 11 9 7 13 1 15 3 17 5 DIMM19 12 10 8 14 2 16 4 18 6 11 9 19 7 17 13 1 15 3...

Страница 31: ...Software Rack Select your server model Please check latest information and versions on ESMPRO portal site before using NEC ESMPRO Manager NEC ESMPRO ServerAgentService and Express Report Service Expr...

Страница 32: ...controllable However theserver may recover from the RSOD by turning off and then on the power again To recover from this condition power off and then on the server again If the problem persists contac...

Страница 33: ...nu under System Utilities See Backup and Restore of RBSU Settings in Maintenance Guide Common About the change of specification in Fault tolerant memory function ADDDC Specification of the Fault toler...

Страница 34: ...Configuration Utility enable BMC Configuration Utility Setting Option Require user login and configuration privilege for BMC Configuration It isn t protected by setting of BIOS Platform configuration...

Страница 35: ...saved the pop up 3 appears and the settings are not saved As a result the pop ups 2 will be displayed as many as the number of the PCIe slots every time this menu is displayed In this case MCTP Broadc...

Страница 36: ...etting Permanentlydisallowdowngrades isset downgradeofanyfirmwarecannotbedoneafterward Thesetting of this Permanently disallow downgrades is permanent and irreversible and users cannot change this set...

Страница 37: ...upted screen display of UUID in iLO Web interface If the iLO is reset during POST execution the display of UUID and UUID logic in iLO Web interface Information Overview page may be corrupted When any...

Страница 38: ...regreaterthan orequal to1 43 and lower than2 10 LastFirmware ScanResult is displayed in Information Security Dashboard Do not click this Hyperlink If you click this link by mistake you won t be able t...

Страница 39: ...sh restart or etc init d ams sh restart Command depends on the version of AMS you are using ESXi7 0 Enter the following command etc init d amsd restart About Java IRC session timeout message While Int...

Страница 40: ...S8 10 006 03 you need to update theAMS separately For further explanation about the updating please check the Starter Pack website If you want to useAgentless Management Service AMS 1 40 0 0 please do...

Страница 41: ...settings of the option as follows Obtain an IP address automatically for IP address and Obtain DNS server address automatically for DNS address e Follow the user s guide to add a CPU board f SetIPaddr...

Страница 42: ...Manager For details refer to Chapter 2 Installation in NEC ESMPRO Manager Ver 6 Installation Guide Windows PDF Phenomena regarding iLO Receiving Information ilo_en mtb Intend for users of NEC Express...

Страница 43: ...38 is applied In case that the screen display of Heartbeat Lost sensor Health vCenter Status shows Warning Yellow after ESXi completes boot for the ports whose cables are connected the Warning Yellow...

Страница 44: ...03 239 SSD Adapter for OS Boot the RAID monitoring report will be changed to snmp trap reporting For details please check the following website NEC Support Portal http www 58support nec co jp global d...

Страница 45: ...completed the iLO is restarting the Status LED flashes in green onceper second the iLO is operating normally through the restart completion the Status LED lights in green 6 If the confirmation succee...

Страница 46: ...bled in the following settings as below 1 System Configuration BIOS Platform Configuration RBSU System Options Serial Port Options BIOS Serial Console and EMS BIOS Serial Console Port Disabled 2 Syste...

Страница 47: ...tting of this product is modified at the factory for disable internal micro SD card slot by the following procedure There is no influence on usual server operation since internal micro SD card slot is...

Страница 48: ...figuration RBSU Memory Optionsfromthe System Utilities the Memory Options menu appears For details about the additional options see the table below Option Parameter Description Memory Controller Inter...

Страница 49: ...ble for Remote InvItoM and Remote WViLF Enable Disable IODC IO Direct Cache Generate snoops instead of memory lookups for remote InvItoM IIO and or WCiLF cores Default setting 5 Server Security Menu W...

Страница 50: ...ion PCIe Slot XX Bifurcation Auto Slot Bifurcated Ifthedeviceinstalledintheslotsupports thiscapability the SlotBifurcated can be selected When Auto is selected the PCIe slot will train at the maximum...

Страница 51: ...Cooling provides additional cooling to the processors When running certain processor intensive workloads this option can provide additional cooling to the processors which can result in improved perf...

Страница 52: ...ions to set Advanced Memory Protection to Fault Tolerant Memory ADDDC From the System Utilities select System Configuration BIOS Platform Configuration RBSU Memory Options to set Advanced Memory Prote...

Страница 53: ...Operations to set Advanced Memory Protection to Fault Tolerant Memory ADDDC From the System Utilities select System Configuration BIOS Platform Configuration RBSU Memory Options to set Advanced Memory...

Страница 54: ...istent Memory Options menu appears When you select System Configuration BIOS Platform Configuration RBSU Memory Options Persistent Memory Options from the System Utilities the Persistent Memory Option...

Страница 55: ...9 1 11 3 17 DIMM 8 16 6 14 10 2 12 4 11 9 7 13 1 15 3 17 5 18 DIMM 12 10 8 14 2 16 4 18 6 11 9 7 13 1 15 3 17 5 19 DIMM 12 10 8 14 2 16 4 18 6 11 9 19 7 17 13 1 15 3 5 20 DIMM 12 10 20 8 18 14 2 16 4...

Отзывы: