1.16.2
Notes on Building RAID System
Note the following points when setting up a RAID System.
•
The number of hard disk drives required varies in each RAID level.
•
If the optional RAID Controller is used, the RAID System cannot be built in
RAID5/RAID6/RAID50/RAID60.
The minimum number of hard disk drives required to set up a RAID System
RAID level
N8103-172
N8103-168/173/174
RAID 0
1
1
RAID 1
2
2
RAID 5
3
RAID 6
3
RAID 10
4
4
RAID 50
6
RAID 60
6
•
In the RAID System, all the hard disk drives in a group (pack) must have the same capacity, interface
type, and rotational speed.
•
If you intend to install the OS to the RAID System, the process from RAID configuration to OS installation
can be easily completed by using EXPRESSBUILDER. If you wish to install the OS manually, use RAID
System Configuration utility (WebBIOS). The utility can be run during POST which starts immediately
after the server is turned on. For details, see
Chapter 2 (4. RAID System Configuration)
in "
Maintenance
Guide
" or the manual supplied with the optional RAID Controller (N8103-168/172/173/174).
Important
•
Do not change the mode to hibernate while building a RAID System.
•
Build a Disk Array in the RAID System using hard disk drives that have the
same specifications (capacity, rotational speed, and standard).