NEC Express Server

 

Express5800 Series 

10.102.01-101.01

July 2013, First Edition

© NEC Corporation 2013

Express5800/R120e-1M 
EXP291 
User’s Guide 

Model Number:  N8100-2073F 

 

Chapter 1  General Description 

Chapter 2  Preparations 

Chapter 3  Setup 
 
Chapter 4  Appendix 

Содержание Express5800/R120e-1M EXP291

Страница 1: ...800 Series 10 102 01 101 01 July 2013 First Edition NEC Corporation 2013 Express5800 R120e 1M EXP291 User s Guide Model Number N8100 2073F Chapter 1 General Description Chapter 2 Preparations Chapter...

Страница 2: ...connection of peripheral devices and ideal location for this server Chapter 3 Setting Up Your Server System BIOS configurations and summary of EXPRESSBUILDER PDF Chapter 4 Appendix Specifications and...

Страница 3: ...ty notes 5 General 5 Rack installation 5 Power supply and power cord use 5 Installation relocation storage and connection 5 Cleaning and working with internal devices 5 During operation 5 Warning labe...

Страница 4: ...69 1 10 6 Removal Replacement 70 1 10 7 Using Memory RAS Feature 71 1 11 Extra Battery Flash Backup Unit for RAID Controller 79 1 11 1 Handling precautions 79 1 11 2 Installing Battery N8103 153 162 7...

Страница 5: ...e 123 1 1 2 POST error messages 124 2 BIOS Setup Utility SETUP 125 2 1 Overview 125 2 2 Starting and Exiting SETUP Utility 125 2 2 1 Starting SETUP 125 2 2 2 Exiting SETUP 125 2 3 Description on On Sc...

Страница 6: ...e Indicates items that must be confirmed when handling the server or operating software Tips Indicates information that is helpful to keep in mind when using this server Optical disk drives This serve...

Страница 7: ...fficial names of Windows Widnows Server 2012 Standard Windows Server 2012 Widnows Server 2012 Datacenter Windows Server 2008 R2 Standard Windows Server 2008 R2 Windows Server 2008 R2 Enterprise Window...

Страница 8: ...or trademarks of Adaptec Inc of the United States LSI and the LSI logo design are trademarks or registered trademarks of LSI Corporation Adobe the Adobe logo and Acrobat are trademarks of Adobe System...

Страница 9: ...BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS AS IS AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE D...

Страница 10: ...que de la classe A est conforme la norme NMB 003 du Canada CE Australia and New Zealand Statement This is a Class A product In domestic environment this product may cause radio interference in which c...

Страница 11: ...tion Of the use of certain Hazardous Substances in Electrical and Electronic Equipment adopted by Order 1057 of Cabinet of Ministers of Ukraine The Product is in conformity with the requirements of Te...

Страница 12: ...120e 1M User s Guide 12 Ukrainian 1057 2 1 Pb 0 1 1000 2 Cd 0 01 100 3 Hg 0 1 1000 4 Cr6 0 1 1000 5 PBB 0 1 1000 6 PBDE 0 1 1000 Russian 1057 2 1 Pb 0 1 1000 2 Cd 0 01 100 3 Hg 0 1 1000 4 Cr 6 0 1 100...

Страница 13: ...omissions please contact your retailer 5 Regardless of these 4 items NEC Corporation does not take responsibility for effects resulting from operations 6 The sample values used in this document are n...

Страница 14: ...WARNING or CAUTION is used to indicate a degree of danger These terms are defined as follows WARNING Indicates there is a risk of death or serious personal injury CAUTION Indicates there is a risk of...

Страница 15: ...shock or fire may be caused Do not touch the server with wet hand Otherwise an electric shock may be caused Do not touch the component specified by this symbol Otherwise an electric shock or burn may...

Страница 16: ...shock Use a rack that conforms to the designated standard This server can be mounted onto a 19 inch rack that conforms to EIA standards Do not mount the server onto any rack that does not conform to E...

Страница 17: ...ponents such as the door or rails When installing the door make sure that both upper and lower hinge pins are held in place Incomplete attachment may cause components to fall off as well as personal i...

Страница 18: ...ngle outlet by using extension cords The electric current exceeding the rated flow overheats the outlet which may cause a fire Insert the power plug into the outlet as far as it goes Heat generation r...

Страница 19: ...ied Do not install the server in the following places or any place other than specified in this User s Guide Failure to follow this instruction may cause a fire A dusty place A humid place such as nea...

Страница 20: ...the server with loose cable connections Do not use any damaged cable Cleaning and working with internal devices WARNING Do not disassemble repair or alter the server Never attempt to disassemble repa...

Страница 21: ...rver during thunderstorms Do not touch any part of the server including the cables when a thunderstorm is approaching Also do not connect or disconnect any devices There may be a risk of electric shoc...

Страница 22: ...tial hazards This label is either attached or printed on the component to draw attention from users to potential hazards involved in handling the server Do not remove or black out this label and keep...

Страница 23: ...rantee that any copy protected CD that does not conform to standards will play on the server s optical disk drive In the following cases check and adjust the system clock before operation After transp...

Страница 24: ...from reflecting bright lights and to make the display contents easy to see Working without adjusting the display to a comfortable angle makes it difficult for you to maintain a proper posture and you...

Страница 25: ...the features of this server and the name of each part 1 Introduction 2 Accessories Verify the condition of your server s accessories 3 Standard Features This section describes the server s features an...

Страница 26: ...processor NEC s latest technology and architectures realize high power and high speed operation that cannot be matched by existing servers The server is designed with consideration of not only reliabi...

Страница 27: ...er is unmounted Getting Started 1 Instruction manuals are stored in EXPRESSBUILDER Adobe Reader is required to read or print them Make sure you have all accessories and inspect them If an accessory is...

Страница 28: ...eading Technology feature 1 High speed memory access DDR3L 1600 1866 supported 2 High speed disk access SATA SAS 6Gbps supported High speed 1000BASE T 100BASE TX 10BASE T 2 ports interface 1Gbps 100Mb...

Страница 29: ...lanes 1 slot dedicated to RAID Controller PCI Express 3 0 x8 lanes 1 slot dedicated to LAN Riser card Large capacity memory of up to 1 5 TB 3 Can upgrade to multi processor system with up to two proce...

Страница 30: ...MP Switch Feature to back up and restore BIOS BMC settings using EXPRESSSCOPE Profile Key 1 Unsupported on Xeon processor E5 2609 v2 embedded models 2 Processor core speed depends on processor type nu...

Страница 31: ...orts keyboard mouse and video Monitors temperatures fans voltage power supply and others Temperature Monitors the temperature inside of the chassis Fan Monitors the fans Voltage Monitors the voltage i...

Страница 32: ...sion Management Use of NEC ESMPRO Manager and ExpressUpdate Agent allows you to manage versions of firmware and software as well as update them by applying update packages This feature automatically u...

Страница 33: ...T LED This LED turns on when the server is connected to the network See page 5 3 1 LAN connector 1 3 2 LAN connector 2 3 3 LAN connector 3 3 4 LAN connector 4 LEDs for LAN3 and LAN4 are lit when optio...

Страница 34: ...this switch to reset the server 14 DUMP Switch NMI When DUMP Switch is pressed memory dump is performed 15 Unit ID UID Switch LED The switch to turn on and off UID LED Pressing the switch once turns o...

Страница 35: ...is enabled in ROM Utility LAN connector 1 can also be used as the management LAN port Sharing port is not recommended from the point of performance and security 11 SPEED LED The LED indicates the tra...

Страница 36: ...4 Names and Functions of Parts Express5800 R120e 1M User s Guide 36 Chapter 1 General Description 4 4 External View 1 Top Cover 2 Release Button...

Страница 37: ...N5F R 6 FAN6F R optional 7 FAN7F R optional 8 FAN8F R optional FAN1 to FAN5 are factory installed FAN6 to FAN8 are required in 2 CPU configuration 4 Processor Optional 5 DIMM optional 6 Support bar 7...

Страница 38: ...and Functions of Parts Express5800 R120e 1M User s Guide 38 Chapter 1 General Description 4 6 Motherboard 5 22 8 1 27 25 5 13 17 16 14 15 14 12 11 10 9 26 8 2 7 6 5 4 3 2 1 1 2 1 2 2 5 18 5 23 19 13 2...

Страница 39: ...n additional RS 232C connector kit N8117 01A to use this port as a serial port 17 SPI Flash Mezzanine connector EXPRESSSCOPE Profile Key SPI flash memory has been installed where BIOS and BMC configur...

Страница 40: ...ower ON OFF status of the server The following table lists POWER LED patterns POWER LED pattern Description On green The server is normally powered on On amber BMC is being initialized When the power...

Страница 41: ...pressed Note It remains green if the dump is caused by software Wait until the memory dump is completed On amber A temperature alarm was detected Check the internal fan for dusts Also check if the fa...

Страница 42: ...act your sales representative Flashing green and amber alternately only when RAID system is configured Rebuild is in progress Off Hard disk drive is halted 4 7 5 Optical Disk Drive Access LED The LED...

Страница 43: ...ailing Contact your sales representative Flashing green and amber alternately only when RAID system is configured Rebuild is in progress When the failed hard disk drive is replaced rebuild process sta...

Страница 44: ...erver is accessing network Off The server is disconnected from network SPEED LED 1 2 M This LED indicates which network interface is used Two onboard LANs 1 2 support 1000BASE T 100BASE TX and 10BASE...

Страница 45: ...rns AC POWER LED pattern Description Solution On green The server is powered on The power cable is connected and AC power is supplied Flashing green Cold Redundant feature is enabled See page 97 The p...

Страница 46: ...ations This chapter describes preparations for using this server 1 Installing Internal Optional Devices You can skip this section if you did not purchase any optional devices 2 Location and Connection...

Страница 47: ...and remove optional devices properly and safely WARNING Be sure to observe the following precautions to use the server safety Failure to observe the precautions may cause death or serious injury For...

Страница 48: ...rotection Clothing Do not wear wool or synthetic clothes Wear anti static shoes Remove any kind of metal accessories such as a ring bracelet or wrist watch Handling of Components Keep the component in...

Страница 49: ...target server See Chapter 2 1 4 Confirming Servers UID Switch 2 Remove Front Bezel See Chapter 2 1 5 Removing Front Bezel 3 If the server is ON turn it off See Chapter 3 6 Turning Off the Server 4 Di...

Страница 50: ...rack See Chapter 2 2 1 2 1 Installation 10 Install hard disk drives See Chapter 2 1 18 Hard Disk Drive 11 Install power supply units See Chapter 2 1 19 Power Supply Unit 12 Attach Front Bezel See Cha...

Страница 51: ...ID Unit ID Switch helps you to identify the target server When the server is working before you turn the server off or disconnect a cable from the server be sure to identify the target server by using...

Страница 52: ...llow the steps below 1 Insert the attached Bezel Lock Key into the key slot and turn the key to the front bezel side while pressing it lightly to release the lock Unlocked Locked 2 Pull the Front Beze...

Страница 53: ...sk drive LAN riser card DIMM Processor TPM module Internal Flash Memory Additional HDD cage PCI card RAID Controller Battery for RAID Controller 1 See steps 1 to 5 in Chapter 2 1 3 Overview of Install...

Страница 54: ...h Memory optional 1 7 1 Installation Install Internal Flash Memory in the following procedure 1 See steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Attach Interna...

Страница 55: ...edure for installing optional TPM Kit 1 8 1 Installation Install TPM Kit in the following procedure 1 See steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Install...

Страница 56: ...roblem for operation 1 9 1 Maximum number of processor cores supported by this server The maximum number of processor cores logical processors available on the server depends on the architecture x86 a...

Страница 57: ...steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Locate the CPU socket to which you are going to install a processor 3 Remove the screws that secure the dummy cove...

Страница 58: ...touch the socket contacts 8 Put the additional processor on the CPU socket slowly and gently For easy installation hold edges of processor with your thumb and index fingers so that the notch is align...

Страница 59: ...socket lever marked with to fix it 11 Close the socket lever marked with to fix it 12 Put the heat sink on the processor and fix the heat sink with four screws Temporarily tighten the four screws diag...

Страница 60: ...stall it again The following probably causes the heat sink not to be level The CPU is not positioned correctly All screws are not completely tightened Do not move the secured heat sink 14 Install an a...

Страница 61: ...nal devices mount and connect the server and turn it on 20 Run BIOS Setup Utility SETUP to confirm the following settings See Chapter 2 1 Details of System BIOS in Maintenance Guide Advanced Processor...

Страница 62: ...remove any processor unless it is failed To remove the heat sink from the processor first turn the heat sink to the left and right lightly to make sure that the heat sink can be apart from the process...

Страница 63: ...figuration No DIMM is factory installed in standard configuration 1 10 1 Maximum supported memory size The maximum available memory size on the server depends on the architecture and OS specs List of...

Страница 64: ...N8102 540F 64GB DDR3 1600 LR Memory Kit 5 sets 10 DIMMs or more 1066 MHz 1066 MHz N8102 541F 128GB DDR3 1333 LR Memory Kit 1066 MHz 1066 MHz N8102 545F 16GB DDR3 1866 REG Memory Kit N8102 546F 32GB D...

Страница 65: ...16GB DDR3 1600 REG Memory Kit N8102 550 32GB DDR3 1600 REG Memory Kit 5 sets 10 DIMMs or more 800 MHz 1066 MHz Up to 4 sets 8 DIMMs 1600 MHz 1600 MHz N8102 540F 64GB DDR3 1600 LR Memory Kit 5 sets 10...

Страница 66: ...ble below for RAS features supported by additiional memory board List of features supported by additiional memory board N code Product name Standard feature x4 SDDC Memory Mirroring feature Memory Loc...

Страница 67: ...s on combination of DIMMs to be installed See the table below to find allowable combination of DIMMs and install DIMMs starting from the largest capacity and from the smallest slot number N8102 N code...

Страница 68: ...5 3 1 3 7 11 3 7 11 9 5 1 9 5 1 4 8 12 4 8 12 10 6 2 10 6 2 CPU1_DIMM 3 CPU1_DIMM 7 CPU1_DIMM 11 CPU1_DIMM 4 CPU1_DIMM 8 CPU1_DIMM 12 CPU1_DIMM 10 CPU1_DIMM 6 CPU1_DIMM 2 CPU1_DIMM 9 CPU1_DIMM 5 CPU1...

Страница 69: ...al part 4 Attach the duct 5 Continue to install or remove internal optional devices mount and connect the server and turn it on 6 Confirm that no error messages are displayed in POST screen If any err...

Страница 70: ...ective DIMM is installed At least one DIMM needs to be installed for the server to operate Take the steps below after replacing or removing DIMMs 1 Confirm that no error messages are displayed on POST...

Страница 71: ...automatic correction of memory error multi bit error Note See List of features supported by additiional memory board in 1 10 3 Memory RAS Feature before using memory RAS feature Only the features that...

Страница 72: ...channels 0 and 1 or channels 2 and 3 To use Memory Mirroring feature install N8102 548 549 550 additional memory board two DIMMs of same model DIMMs used in mirror set must be of the same model number...

Страница 73: ...parameter Advanced Memory Configuration Memory Information CPUx_DIMMx Status Installation order depends on CPU configuration See the figure below Memory Mirroring cannot be configured in the followin...

Страница 74: ...rection With this feature a single device can detect and correct one to eight bit error Note Memory LockStep feature uses channels 0 and 1 or channels 2 and 3 To use Memory LockStep feature install N8...

Страница 75: ...below Memory Lock Step cannot be configured in the following cases Memory Lock Step between memory channels of different memory controllers CPU Memory Lock Step within the same memory channel Notes on...

Страница 76: ...re install N8102 552 553 554 additional memory board three DIMMs of same model DIMMs installed in the system must be of the same model number Tips The operating system recognizes the DIMMs as those wi...

Страница 77: ...splayed in Sparing See Chapter 2 1 System BIOS in Maintenance Guide run SETUP change parameters as shown below save the settings and exit from SETUP Advanced Memory Configuration Memory RAS Mode Chang...

Страница 78: ...u additionally install DIMMs that unable to configure Memory Sparing When you remove DIMMs that takes down Memory Sparing 1CPU 2CPU 3 3 3 4 4 4 2 2 2 1 1 1 5 5 5 7 7 7 3 3 3 1 1 1 6 6 6 8 8 8 4 4 4 2...

Страница 79: ...e precautions may cause damage to your data or other devices Use the extra battery or FBU appropriate to the RAID Controller to be used The extra battery is an electronic device sensitive to static el...

Страница 80: ...llation position of the battery depends on installed RAID Controller See the figure on the right Install N8103 162 additional battery to the position for PCI slot 1 or 1C PCI 1B 1C RAID PCI 1A RAID 7...

Страница 81: ...2 Install RAID Controller to the RAID Controller connector on motherboard using two screws you have removed in Step 10 13 Connect Mini SAS cable to RAID Controller 14 Install support bar and PCI riser...

Страница 82: ...the battery tray for RAID Controller 5 Put the FBU provided as the standard accessory of RAID Controller on the battery tray Then mount the FBU bracket provided as the standard accessory of RAID Cont...

Страница 83: ...of RAID Controller 9 Remove one screw from the blank cover on the PCI riser card removed in Step 2 on which you are going to mount the RAID Controller then remove the blank cover 10 Mount the RAID Con...

Страница 84: ...all LAN Riser Card Important You must avoid static electricity to work with the procedure below For details see Chapter 2 1 2 Anti static Measures 1 12 1 Installation Follow steps below to install LAN...

Страница 85: ...h the LAN Riser Card slot and insert the card securely 7 Secure the bracket of LAN Riser Card with two screws you have removed in step 5 8 Install the port cover provided with LAN Riser Card 1 12 2 Re...

Страница 86: ...card slot Slot 1D dedicated to LAN riser card The PCI devices of the same type including onboard PCI device may be recognized in different order from that described above depending on OS or RAID Conf...

Страница 87: ...b s Slot size Dedicated to RAID Controller Full height Low profile Dedicated to LAN riser card PCI card type 2 x8 socket x16 socket x8 socket Model name Product name Available card size Dedicated to R...

Страница 88: ...necting external Fibre Channel device Cannot be installed together with N8190 157 158 N8190 157 Fibre Channel Controller 16Gbps Optical PCI Express 3 0 x8 N8190 158 Fibre Channel Controller 2ch 16Gbps...

Страница 89: ...er SFP 2ch PCI Express 2 0 x8 For additional LAN port Prepare SFP module N8104 129 if needed Only one card can be installed in RHEL6 Up to two cards including N8104 136 137 128 148 131 can be installe...

Страница 90: ...m the installation position with the reference to the table on 1 14 2 Supported boards and available slots 4 Remove the screw from the PCI riser card and remove the blank cover Note Keep the removed b...

Страница 91: ...POST Error Message in Maintenance Guide 10 Start the configuration utility installed on the mounted board to set up the board Availability or startup and operation procedure of the utility depends on...

Страница 92: ...dvanced menu and then make sure that the parameter of PCI Slot xx ROM xx is PCI slot number is set to Enabled When connecting a RAID Controller set the boot priority to 8th or higher in the Boot menu...

Страница 93: ...SAS SATA cable removed in Step 9 to connector Ports 0 3 on RAID Controller Connect SAS SATA cable provided with the server to connector Ports 4 7 on RAID Controller Remove a single screw from server c...

Страница 94: ...clusively with the optical disk drive 1 14 1 Installation Follow steps below to install an additional HDD cage 1 See steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations...

Страница 95: ...additional HDD cage to the chassis and secure it with screws 1 14 2 Removal To remove additional HDD cage reverse the installation procedure Important Before removing additional HDD cage be sure to r...

Страница 96: ...disk drive 1 15 1 Installation Install an optical disk drive in the following procedure 1 See steps 1 to 6 in Chapter 2 1 3 Overview of Installation and Removal for preparations 2 Remove the two screw...

Страница 97: ...tray 6 Secure the bracket to optical disk drive with a screw you have removed in Step 3 7 Insert the optical disk drive and secure the drive tray with two screws you have removed in Step 2 8 Connect t...

Страница 98: ...contains valuable data be sure to backup the hard disk drive before installing the RAID Controller and configuring the RAID System Note In the RAID System use hard disk drives that have the same spec...

Страница 99: ...AID Controller Hard Disk Drive Backplane SLOT 0 SATA 0 SLOT 1 SATA 1 SLOT 2 SATA 2 Ports 0 3 SLOT 3 SATA 3 SLOT 4 SATA 4 SLOT 5 SATA 5 Ports 4 7 When optional 2 5 inch HDD cage is installed Optional R...

Страница 100: ...drives in a group pack must have the same capacity interface type and rotational speed If you intend to install the OS to the RAID System the process from RAID configuration to OS installation can be...

Страница 101: ...17 Installing Top Cover When all internal optional devices are installed close the server with Top Cover 1 Put Top Cover straight on the server chassis so that it can be surely engaged with the chassi...

Страница 102: ...he following precautions to install hard disk drives For onboard connection hard disk drives having different capacities types or rotational speeds cannot be installed together In the RAID System all...

Страница 103: ...f Installation and Removal for preparations 2 Locate the slot where you install the hard disk drive The server has 6 slots or 8 slots when additional HDD cage is installed Install hard disk drives in...

Страница 104: ...drive reverse the installation procedure If you transfer or dispose of the removed hard disk drive see Chapter 1 1 Transfer Movement and Disposal in Maintenance Guide to erase data Important NEC assum...

Страница 105: ...eplacing a hard disk drive while the power on a failed hard disk drive During the auto rebuild DISK LED on the hard disk drive flashes green and amber alternately to indicate that the auto rebuild is...

Страница 106: ...as described below Cold redundant feature can run the system with optimum power efficiency by raising operating efficiency of primary power supply unit and lowering that of redundant power supply uni...

Страница 107: ...ve the blank cover Note Keep the removed blank cover for future use 3 Insert the power supply unit until it is locked with clicking sound 4 Connect power cords Use the power cord that comes with the s...

Страница 108: ...C POWER LEDs on both power supply units blink green 5 Power on the server AC POWER LEDs go on green 6 Confirm by STATUS LED or on POST screen that there are no errors related to the power supply units...

Страница 109: ...d property damage For details refer to Safety precautions in Precautions for Use Pay attention to electric hazard Important Do not remove a power supply unit operating normally Tips In the redundant p...

Страница 110: ...R120e 1M User s Guide 110 Chapter 2 Preparations 1 20 Installing Front Bezel When installing Front Bezel engage catch of front bezel with that on rails After installing Front Bezel lock it with Bezel...

Страница 111: ...nly in the specified environment Do not connect the ground wire to a gas pipe CAUTION Be sure to observe the following precautions to use the server safely Failure to observe the precautions may cause...

Страница 112: ...orrosive gases sulfur dioxide hydrogen sulfide nitrogen dioxide chlorine ammonia ozone etc exist Place where the air or dust includes components accelerating corrosion ex sulfur sodium chloride or con...

Страница 113: ...cautions to use the server safely Failure to observe the precautions may cause burns injury and property damage For details refer to Safety precautions in Precautions for Use Do not drop Do not leave...

Страница 114: ...ount an outer rail marked as R to the right side of the rack and L to the left side when viewed the rack from front 2 Fit the square shaped protrusions of outer rail to the square holes of a 19 inch r...

Страница 115: ...tempt to lift the server with single person Do not drop Do not leave the server being pulled out Do not install with the cover removed Do not get your fingers caught 1 Installation Mount the server to...

Страница 116: ...ock on front panel clicks 2 Removal procedure Remove the server from the rack in the following procedure Important At least two persons are required to remove the server from rack 1 Make sure that the...

Страница 117: ...ttom part of the server slowly pull out the server Do not apply pressure on the server from top when it is being pulled out Doing so cause the server to drop 3 Removing Outer Rail Remove outer rails f...

Страница 118: ...death or serious injury For details refer to Safety precautions in Precautions for Use Do not hold the power plug with wet hands Do not connect the ground wire to a gas pipe CAUTION Be sure to observ...

Страница 119: ...ce Display unit 2 Hub switching hub etc Management LAN port Ports for data transmission Device with serial interface USB device FRONT REAR Finally connect the provided power cord to an outlet 1 For co...

Страница 120: ...ruptible Power Supply UPS To connect the power cord of the server to a UPS use the connector output on the rear of the UPS For details refer to the manual supplied with the UPS When the power cord is...

Страница 121: ...IOS settings by following the instructions in this section 3 EXPRESSSCOPE Engine 3 EXPRESSSCOPE Engine 3 provides useful features through Baseboard Management Controller BMC 4 EXPRESSBUILDER EXPRESSBU...

Страница 122: ...ver 1 Turn on the peripheral devices and display unit Note If the power cord is connected to power control system such as an Uninterruptible Power Supply UPS make sure that the power control system is...

Страница 123: ...displayed a screen is sometimes switched over to the screen by which nothing is displayed black screen several times It s no problem for operation An initialization message isn t sometimes displayed b...

Страница 124: ...Tools in Maintenance Guide F12 key Boot from network 6 If a controller which has its dedicated BIOS such as a RAID Controller board is installed a message that prompts you to start the dedicated utili...

Страница 125: ...g SETUP Run POST following Chapter 3 1 1 1 POST sequence After a while the following message will be displayed on the lower left of the screen Press F2 SETUP F3 Internal Flash Memory F4 ROM Utility F1...

Страница 126: ...r of the selected item You cannot use this key when a menu which has on the left is selected Enter key Press this key to confirm the selected parameter Esc key Pressing this key takes you to the previ...

Страница 127: ...No F3 key If you press this key the following window appears If you select Yes restore the parameters of the currently selected item to the default setting This might be different from the parameters...

Страница 128: ...oller and Option ROM Settings PCIXX Slot Option ROM Disabled XX is PCI slot number of the installed option board Change the boot order of devices Boot Boot Option Priorities Change the boot priority W...

Страница 129: ...ong password 3 times operation stops You cannot operate further Turn off the power Saving changes If you finish configuration select Save Exit and then Save Changes and Exit to save changes and exit I...

Страница 130: ...e these functions virtual USB mass storage Remote FD Remote CD DVD Remote USB Memory or Virtual Flash is always connected as USB mass storage 3 2 EXPRESSSCOPE Engine 3 Network Configuration To enable...

Страница 131: ...e feature may be interrupted In this case wait for a while and connect with network again 5 If Property is selected the following screen is displayed On this screen specify Enable if you want to use D...

Страница 132: ...l menu in the menu after boot Documents Stores various documents including User s Guide Installation Guide and Maintenance Guide Documents and some software components are not stored in N8115 05 Inter...

Страница 133: ...Software Components Express5800 R120e 1M User s Guide 133 Chapter 3 Setup 5 Installing Software Components Continue to install software components such as OS See the instructions below Installation G...

Страница 134: ...he server is connected to a UPS refer to the documentation supplied with the UPS or the documentation for the application controlling the UPS 1 Shut down the OS 2 The server automatically turns off af...

Страница 135: ...Express5800 R120e 1M User s Guide 135 NEC Express5800 Series Express5800 R120e 1M Appendix 1 Specifications 2 Interrupt Lines...

Страница 136: ...sub 9 pin Serial port A 1x rear optional port can be used up to two ports in total 2x 1000BASE T LAN connector 1000BASE T 100BASE T 10BASE T supported RJ45 2x rear 1x Management LAN connector 100BASE...

Страница 137: ...used up to two ports in total 2x 1000BASE T LAN connector 1000BASE T 100BASE T 10BASE T supported RJ45 2x rear 1x Management LAN connector 100BASE T 10BASE T supported RJ45 1x rear Power supply unit N...

Страница 138: ...devices Interrupt lines As factory settings interrupt lines are assigned as follows IRQ Peripheral Device Controller IRQ Peripheral Device Controller 0 System timer 12 SM Bus 1 13 Numeric data proces...