Chapter 2 Useful Features
For details about the options, see the table below.
Option Parameter
Description
Serial Port B Settings
–
–
Serial Port B
Disabled
[Enabled]
Enables or disables serial Port B.
Serial B Base I/O
3F8h
[2F8h]
3E8h
2E8h
Specifies the base I/O address for serial port B.
Serial B Interrupt
IRQ 4
[IRQ 3]
Specifies the interrupt for serial port B.
Console Redirection Settings
–
–
BIOS Redirection Port
[Disabled]
Serial Port B
Enables or disables console redirection for a specified serial port.
Specifying
Serial Port B
allows direct connection via a terminal
unit such as NEC ESMPRO Manager.
The screen size of the terminal unit must be 80 x 25. The option
items shown below are displayed.
Terminal Type
[VT100+]
VT-UTF8
ANSI
Specifies the terminal type.
Baud Rate
9600
19200
57600
[115200]
Specifies the baud rate.
Data Bits
7
[8]
Specifies the data bit width.
Parity [None]
Even
Odd
Specifies the parity bits.
Stop Bits
[1]
2
Specifies stop bits
Flow Control
None
[Hardware RTS/CTS]
Specifies the flow control method.
Continue C.R. after POST
Disabled
[Enabled]
Specifies whether to continue console redirection after POST
completes.
[ ]: Factory setting
Note
The parameters for the serial ports A and B are contained in NEC ESMPRO Manager,
Online BMC Configuration Tool, and EXPRESSSCOPE Engine 3. However, the setting for
serial port A are invalid because this server does not have serial port A.