1. Error Message of POST and Virtual LCD
Express5800/B120g-h Maintenance Guide
155
Chapter 3 Appendix
Error Message
Cause
Solution
C120 BMC Runtime FW corrupted.
Failed to start BMC FW.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C121 BMC Force Update FW corrupted.
Failed to start BMC FW.
C122 BMC Configuration area
corrupted.
An error occurred on BMC
Configuration area.
C123 BMC eMMC inaccessible.
Initialization failed due to an access
error occurred in internal flash
memory of BMC.
C125 BMC eMMC mode error.
A mode error occurred in internal
flash memory of BMC.
C126 BMC
eMMC
partition corrupted.
An error occurred on partition of
internal flash memory of BMC.
C127 BMC eMMC format corrupted.
A format error occurred in internal
flash memory of BMC.
C128 BMC is in Update Mode.
BMC is in firmware update mode.
C300 Out-of-band
setup
configuration failure
An error was detected while
accessing BMC Mezzanine card.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.
C301 SDR mismatch error.
Inconsistency in the hardware
information of the sensor data
record was detected.
Contact your sales representative.
C302 Hardware configuration error.
Detected that hardware
configuration of the server is illegal.
C310 Hardware configuration of
cooling is insufficient.
Detected that cooling power is
insufficient in this hardware
configuration.
Contact your sales representative.
C320 Unmatched
PSUs.
Detected that unmatched power
supply units are configured.
C321 System power consumption is
out-of-range in PSUs.
Detected that system power
consumption exceeds the power
output capacity limit.
C322 No information for system
power consumption check.
Detected that no information was
acquired in checking system power
consumption.
C400 Can't Read FRU on CPU Unit
TypeI Mezzanine
Cannot read Mezzanine Slot1 FRU. Contact your sales representative.
C401 Can't Read FRU on CPU Unit
TypeII Mezzanine
Cannot read Mezzanine Slot2 FRU.
C501 ME is in Recovery Mode.
Intel Node Manager is in Recovery
Mode.
Power off the CPU blade, remove it from
blade enclosure, wait for at least 30
seconds, and then install it again.