![NEC Express 5800/140Rb-4 Скачать руководство пользователя страница 129](http://html.mh-extra.com/html/nec/express-5800-140rb-4/express-5800-140rb-4_service-manual_251155129.webp)
Error Code and Message
Description
Action
firmware
corrupted
firmware corrupted
again to start the server. If the error cannot be
corrected, contact your service representative.
0B92
Internal Use
Area Error
Internal Use Area of
BMC FRU corrupted
All the commands and functions other than the FRU
command and the EMP function can be used. This
is not a fatal error. Turn off the power once and then
on again to restart the server. If the error cannot be
corrected, contact your service representative.
0B93
BMC SDR
Repository
empty
No BMC SDR data
exists
Turn OFF server power source once and then on
again to start the server. If the error cannot be
corrected, contact your service representative.
0B94
IPMB Error
IPMB signal lines do
not respond
All the functions other than the function of accessing
to SMC through IPMB can be used. This is not a
fatal error. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
0B95
BMC FRU
device failure
Access to SROM
that contains the
chassis information
failed
All the functions other than the function of accessing
to SMC through IPMB can be used. This is not a
fatal error. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
0B96
BMC SDR
Repository
failure
Access to FMEM
sector that contains
SDR information
failed
0B97
BMC SEL
device failure
BMC SEL device
failure
0B98
BMC RAM test
error
BMC RAM test error
0B99
BMC Fatal
hardware error
BMC Fatal hardware
error
0B9A
Management
Controller error
Management
Controller not
responding
0B9B
Private I2C error Private I2C bus not
responding
0B9C
BMC
internalexceptio
n
BMC internal
exception
0B9D
BMC A/D
timeout error
BMC A/D timeout
error
0B9E
SDR repository
corrupt
SDR repository
corrupt
0B9F
SEL corrupt
SEL corrupt
Turn OFF server power source once and then on
again to start the server. If the error cannot be
corrected, contact your service representative.
0BB0
SMBIOS –
SROM data
Read error of SROM
data
Содержание Express 5800/140Rb-4
Страница 1: ...Express5800 140Rb 4 Service Guide Express 5800 140Rb 4 Service Guide Document PN 6883250000 ...
Страница 2: ......
Страница 4: ......
Страница 10: ...Figure 2 EXPRESS5800 140Rb 4 Server Labels ...
Страница 20: ......
Страница 32: ......
Страница 34: ......
Страница 36: ......
Страница 106: ......
Страница 137: ......
Страница 139: ...Equipment Log Continued Item Manufacturer Name and Model Number Serial Number Date Installed ...