
5-22
Problem Solving
STATUS LED
Error Message
Color
State
Suspected
module
Description
Procedure
CPU00 Temp Alm
00
Amber Blink CPU module #1
CPU#1 temperature alarm
(lower limit)
CPU00 Temp Alm
02
Amber
Lit
CPU module #1
CPU#1fatal temperature alarm
(lower limit)
CPU00 Temp Alm
07
Amber Blink CPU module #1
CPU#1temperature alarm
(upper limit)
CPU00 Temp Alm
09
Amber
Lit
CPU module #1
CPU#1 fatal temperature
alarm (upper limit)
CPU01 Temp Alm
00
Amber Blink CPU module #1
CPU#2 temperature alarm
(lower limit)
CPU01 Temp Alm
02
Amber
Lit
CPU module #1
CPU#2 fatal temperature
alarm (lower limit)
CPU01 Temp Alm
07
Amber Blink CPU module #1
CPU#2 temperature alarm
(upper limit)
CPU01 Temp Alm
09
Amber
Lit
CPU module #1
CPU#2 fatal temperature
alarm (upper limit)
Check to see if dust is
accumulated on the
internal fans. Check also
if the fan cables are
connected securely. If
not solved by the above,
contact your sales
agent.
CPU2 +12ss Alm
02
Amber Lit
CPU module #2
Fatal 12-V power voltage
alarm (lower limit)
CPU2 +12ss Alm
07
Amber Blink CPU module #2
12-V power voltage alarm
(upper limit)
CPU2 +12ss Alm
09
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (upper limit)
CPU2 +12v Alm
00
Amber Blink CPU module #2
12-V power voltage alarm
(lower limit)
CPU2 +12v Alm
02
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (lower limit)
CPU2 +12v Alm
07
Amber Blink CPU module #2
12-V power voltage alarm
(upper limit)
CPU2 +12v Alm
09
Amber
Lit
CPU module #2
Fatal 12-V power voltage
alarm (upper limit)
CPU2 +1.5vAlm
00
Amber Blink CPU module #2
1.5-V power voltage alarm
(lower limit)
CPU2 +1.5vAlm
02
Amber
Lit
CPU module #2
Fatal 1.5-V power voltage
alarm (lower limit)
CPU2 +1.5vAlm
07
Amber Blink CPU module #2
1.5-V power voltage alarm
(upper limit)
CPU2 +1.5vAlm
09
Amber
Lit
CPU module #2
Fatal 1.5-V power voltage
alarm (upper limit)
Contact your sales
agent.
CPU2 +2.5vAlm
00
Amber Blink CPU module #2
2.5-V power voltage alarm
(lower limit)
CPU2 +2.5vAlm
02
Amber
Lit
CPU module #2
Fatal 2.5-V power voltage
alarm (lower limit)
CPU2 +2.5vAlm
07
Amber Blink CPU module #2
2.5-V power voltage alarm
(upper limit)
CPU2 +2.5vAlm
09
Amber
Lit
CPU module #2
Fatal 2.5-V power voltage
alarm (upper limit)
Contact your sales
agent.
Содержание EXPRESS 320Lb
Страница 1: ... U s e r s G u i d e EXPRESS5800 320Lb 320Lb R ...
Страница 2: ...NEC ...
Страница 4: ......
Страница 91: ......
Страница 158: ...A Technical Specifications Server Unit ...
Страница 161: ......
Страница 162: ...B I O Port Addresses I O Port Addresses ...
Страница 173: ......
Страница 177: ......
Страница 180: ...xx ...
Страница 181: ... 456 01675 000 ...