![NEC ExpEther-2S Скачать руководство пользователя страница 72](http://html.mh-extra.com/html/nec/expether-2s/expether-2s_user-manual_251145072.webp)
52
Parameter name
Parameter
Type
Description
serial_number
Up to 32 bytes
character string
US-ASCII character
(0x20 to 0x7E)
Common Serial number of the ExpEther unit
model
Up to 32 bytes
character string
US-ASCII character
(0x20 to 0x7E)
Common Model name of the ExpEther unit
link_status0
{up | down}
Common Link status of the LAN port-0 of the
ExpEther unit
up:
Link-up
down:
Link-down
Always down for 1G/10G version
link_status1
{up | down}
Common Link status of the LAN port-1 of the
ExpEther unit
up:
Link-up
down:
Link-down
Always down for 1G/10G version
max_eeio_count
For 1G/10G:
0 to 8
For 40G:
0 to16
EESV
Maximum EEIO
The maximum value of PCle slots on
the ExpEther I/O Expansion Unit to
be connected to the ExpEther board
eesv_type
{na | sa | nbc | sbc}
EESV
Type of the ExpEther board
compatibility
{10g | 40g | default}
EESV
1/10GEE compatibility mode
Specify the type of the ExpEther I/O
Expansion Unit connectible to
Downstream ports 0 to 7 of 40G
version EESV.
10g:
1G/10G version
40g:
40G version
default:
Only 40G EEIO can be connected
to Downstream ports 0 to 7.
Only 40G version ExpEther I/O
Expansion Unit can be connected to
Downstream
ports 8 to 15.
This parameter is not displayed if the
type of the ExpEther unit is 1G/10G
version.
power_off_inhibition
_status
{enabled | disabled} EESV
Power OFF inhibition status
enabled:
Power OFF inhibition enabled
disabled:
Power OFF inhibition disabled
When the power off inhibition of the
ExpEther board is enabled, the
power status cannot be updated from
the ExpEther I/O Expansion Unit or
ExpEther clients.
40G version
ExpEther units do not
support power off inhibition.
Therefore, this parameter is not
displayed if the type of the ExpEther
unit is 40G version.
Содержание ExpEther-2S
Страница 2: ... Memo ...
Страница 111: ...91 Memo ...