50
Parameter name
Parameter
Type
Description
status
{eesv | eeio}
Common Type of ExpEther unit
eesv:
Indicates the ExpEther board.
eeio:
Indicates the ExpEther I/O
Expansion Unit or an ExpEther
client.
update_time
0 to
9223372036854775
807
Common Update time of the device
information
Indicates the elapsed milliseconds
from 1970/1/1 00:00:00 000 UTC.
admin_status
{enabled | disabled} Common Administration status of the ExpEther
unit
enabled:
Administration status enabled
disabled:
Administration status disabled
The default is “enabled”.
You can set the ExpEther unit only
when the administration status is
enabled.
monitoring_status
{enabled | disabled} Common Monitoring status of the ExpEther
unit
enabled:
Monitoring status enabled
disabled:
Monitoring status disabled
The default is “enabled”.
notification_status0
{up | down}
Common Continuity status from the LAN port-0
of the ExpEther unit to the LAN port-
0 and 1 of the ExpEther Manager
up:
Periodical notification received
down:
Notification not received for a
certain period
notification_status1
{up | down}
Common Continuity status from the LAN port-1
of the ExpEther unit to the LAN port-
0 and 1 of the ExpEther Manager
up:
Periodical notification received
down:
Notification not received for a
certain period
mac_address
00:00:00:00:00:00
to
FF:FF:FF:FF:FF:FF
Common MAC address of the ExpEther unit
The MAC address whose least
significant bit is “0” is set for a 40G
version
ExpEther unit.
group_id
1 to 4094
Common Group ID
vlan_tagging
{enabled | disabled} Common VLAN tag mode
enabled:
VLAN tag mode enabled
disabled:
VLAN tag mode disabled
This parameter is not displayed
when the type of the ExpEther unit is
10G.
Содержание ExpEther-2S