1. Installing Internal Optional Devices
Express5800/D120h User’s Guide
57
Chapter 2 Preparations
Installation
(1)
RAID controller (N8103-176/177/178/188), and internal SAS/SATA cable (K410-356/K410-357)
Install a RAID controller to the PCI riser card in the following procedure.
Important
•
To avoid static electricity, see
Chapter 1 (1.8 Anti-static Measures)
in Safety
Precautions and Regulatory Notices.
•
When installing a PCI card, make sure the connector of the card fits the connector
of the slot.
Note
•
See the “Boot” described in
Chapter 3 (2.4 Cases That Require Configuration)
, to
select a boot mode to fit your environment.
•
Check the following BIOS settings when you have the RAID controller implemented.
Advanced
→
PCI Subsystem Settings submenu
→
PCI Express Slot x#2
→
Enable
•
To connect a RAID controller, optional SAS/SATA cable (K410-356 or K410-357) is
required.
<1U server module>
- The built-in SAS/SATA cable (K410-356) is required.
See steps 1 and 2 in
Chapter 2 (1.4 Removing Server Module)
for preparation.
Remove the three screws securing the PCI
#1 riser card. Hold the both ends of the riser
card and lift it straight to remove it.
Remove the one screw securing the PCI #2
riser card. Hold the both ends of the PCI
riser card and lift it straight to remove it.