11
CHAPTER 2 CONNECTIONS
2.2
Power ON and OFF Sequence
After the connection of the emulation probe to the target system has been completed, switch on the power.
The sequence for switching the power on/off is shown below.
Caution Be sure to follow the correct sequence for switching the power ON and OFF. Otherwise,
the IE-75001-R could be damaged.
(1) If the IE-75001-R is connected to the target system
•
Power ON sequence
<1> Switch on the power of the IE-75001-R.
<2> Switch on the power of the target system.
•
Power OFF sequence
<1> Switch off the power of the target system.
<2> Switch off the power of the IE-75001-R.
Содержание EP-753304DU-R
Страница 7: ...ii MEMO...
Страница 21: ...14 CHAPTER 3 SETTING MASK OPTIONS MEMO...