![background image](http://html1.mh-extra.com/html/nec/electraelite-ipk/electraelite-ipk_programing-manual_3863195053.webp)
1 - 22
Multiline Terminal Programming
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
16
Voice Prompt to Tone Assignment
PR1
Refer to
1-8-16 Voice Prompt to Tone
Assignment on page 2-203
17
PC Programming Password
Assignment
Class 1, 2 All Blank
N/A
18
Site Name Assignment
Not Assigned
N/A
25
ACD/UCD Group Agent
Assignment
Not Specified
Agent Station Number and ACD/UCD
Group Number
26
Voice Mail Quick Transfer Master
Hunt Number
000
Voice Mail Pilot Number
27
Forced Account Code Length
Assignment
10DGT
1~13 Digits
29
SCD (Simplified Call Distribution)
Pilot Number Assignment
Not Assigned
Pilot Number for up to 4 Groups
30
SCD Group Agent Assignment
Not Assigned
1~4 Digits
31
Hold Tone Source Assignment
INT
INT, EXT
32
Hold Internal Tone Volume
Selection
0dB
0dB, -6dB
33
Master Clock Selection
0: Not Assigned
Cabinet: 0~2
Slot: 1~4
35
COM Port Baud Rate Setting
Assignment
COM 1 = 38.4
COM 2 = 4.8
COM 3 = 9.6
4.8 Kbps, 9.6 Kbps, 19.2 Kbps, 38.4 Kbps
36
COM Port Parity/Stop Bit Setting
Assignment
NON/1
NON/1, NON/2, EVEN/1, ODD/1
37
General Purpose Relay Assignment
NO
NO, YS
38
Modem Number for Remote
Programming Assignment
Not Assigned
Any Unused Extension Number
(1~4 digits)
40
ACD Hunt Time
10s
10s, 20s, 30s, 60s, 120s, 240s,
∞
(
No Limit).
43
Enhanced 911 Trunk Assignment
Not Specified
CO/PBX trunks 01~64
44
Enhanced 911 Alternate Route
Assignment
No Alternate Route
No Alternate Route
101~132 for trunk group 01~32
201~216 for route advance block 01~16
LK 1 System Mode
LK 8 PBR/Miscellaneous (Continued)
Data
No.
Memory Block Name
Default Value
Programming Values