Specifications
DSX-80/160 Hardware Manual
Speci
fi
cations and Parts
◆
75
Specifications
and Parts
FCC Registration Information
Model:
DX7NA-80M and DSX7NA-160M
Manufacturer:
NEC Infrontia
FCC Part 15 Registration:
Class A
FCC Registration Number:
US:NIFKF00BDSX
US:NIFMF00BDSX
US:NIFPF00BDSX
Industry Canada Certi
fi
cate (DOC) Number:
IC: 140k-DSX
Reg. Status
FIC
Mfrs. Port ID
REN
Network Jacks
Original
02LS2
1091005
1091009
REN 0.6B
RJ11C
RJ21X
T1/E1/PRI Card FCC Registration Information
FIC
Description
04DU9-BN
1.544 Mbps Superframe format (SF) without line power
04DU9-ISN
1.544 Mbps ANSI ESF and B8ZS without line power
Cabling Requirements
1. Do not run station cable parallel with the AC source, telex or computer, etc. If the cables are
near cable runs to those devices, use shielded cable with grounded shields or install the cable
in conduit.
2. When cables must be run on the
fl
oor, use cable protectors.
3. Cable runs for key telephones and single line telephones Modules must be a dedicated, iso-
lated cable pair.
Device
Cable Type
Cable Run (ft)
Notes
Key Telephone
2-wire 26 AWG
2-wire 24 AWG
1300
2000
Single Line
Telephone
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
11,500
3150
18,000
5050
29,000
8000
at constant 20 mA
at constant 35 mA
at constant 20 mA
at constant 35 mA
at constant 20 mA
at constant 35 mA
2PGDAD Module
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
650
980
1640
DSX Analog Door
Box to 2PGDAD
Module
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
650
980
1640