Installing a DSX Analog Door Box and 2PGDAD Module
60
◆
Optional Equipment
DSX-80/160 Hardware Manual
Mounting the 2PGDAD Module and Connecting to the System
To mount and connect the 2PGDAD Module:
1.
Mount two suitable fasteners (such as #8 sheet metal screws) about 3 15/16” apart either horizontally (for
horizontal mounting) or vertically (for vertical mounting).
- Leave the heads exposed about 1/4”
2.
Place the 2PGDAD Module over the screws and slide down into place.
3.
Program the Door Box and 2PGDAD Module
before connecting to the 2PGDAD modular jack
.
- In
1203-01: Secondary Station Port Assignment
, for the 16ESIU port selected enter an available
station port for the secondary port (96-127 by default).
- In
2113-02: Ring Group
, assign the extensions associated with the 2PGDAD Module and all tele-
phones that should receive door chimes to the same Ring Group.
- Refer to the
Door Box
feature in the
DSX Software Manual
for additional programming.
4.
Using a standard line cord, plug the 2PGDAD Module into its modular jack and verify the LEDs.
Figure 45: Mounting and Connecting the 2PGDAD Module
1093096 - 49
1
3
2
2
1
2
2
3
4
4