Program 26-03 : ARS Dial Treatments
to assign the 15 Dial Treatments for automatic ARS
dialing translation. Assign Dial Treatments to Service Numbers (Trunk Groups) in Program 26-02.
The ARS Dial Treatment options are:
●
3
- Delete the NPA if dialed as part of the initial call.
Requires at least 8 digits in the ARS table (Program 26-02-01).
●
2
- Delete the leading “1” if dialed as part of the initial call.
Requires at least 8 digits in the ARS table (Program 26-02-01).
●
1
- Add a leading 1 if not dialed as part of the initial call.
Requires at least 8 digits in the ARS table (Program 26-02-01).
●
INPA
- Insert the NPA speci
Þ
ed by NPA.
●
DNN
- Outdial the NN number of digits or execute the code that follows. For example,
D041234 out-dials 1234. Valid entries are 0-9, #, *, Wnn (wait nn seconds) and P (pause).
Each digits code counts as a digit. So for example, if a P was added for a pause, the entry
would look like: D05P1234. This Dial Treatment can only be added from telephone program-
ming.
●
Wnn
- Wait nn seconds.
●
P
- Pause in analog trunk.
●
R
- Redial the initially dialed number, including any modi
Þ
cations
●
E
- End of Dial Treatment. All Dial Treatments must end with the E code.
●
X
- When ARS is enabled, X must be entered in the Dial Treatment in order for the system to
output the extension number of the call’s originator to the black box for the E911 feature.
●
An
- For Alternate Carrier Access (n = 1 ~ 4). The numeric digit instructs the system to insert
a Transit Network Selection information element in the SETUP message and also identi
Þ
es
which code in Program 26-11 will be included in the information element. This function is
valid only for outbound calls by ISDN trunks.
Input Data
Conditions
None
Level:
Aspire S
Aspire M/L/XL
IN
•
Available.
•
Available.
•
“An” Dial Treatment available with 2.64+
software.
•
“An” Dial Treatment available with 2.64+
software.
Dial Treatment Table Number
1-15
Item No.
Input Data
Default
01
24 characters maximum
No Setting
Содержание Aspire Series
Страница 10: ...Table of Contents Table of Contents 8 Aspire Networking Manual...
Страница 20: ...Introduction About This Manual 10 Networking For Your Notes...
Страница 46: ...Setting Up The Networking Feature Numbering Plan 36 Networking For Your Notes...
Страница 48: ...Features 38 Networking For Your Notes...
Страница 108: ...Features Voice Mail Local 98 Networking For Your Notes...
Страница 109: ...Programming Networking 99 Programming Section 3 Programming...
Страница 110: ...Programming 100 Networking For Your Notes...