Chapter 4 : Aspire Conference Bridge PCB Web Manager
Using the Web Manager
Aspire Conference Bridge Manual
◆
29
●
Max Participants Per Conf.
Con
Þ
gures the maximum participants including the organizer in a conference. (Default = 16)
●
Max Conf. Duration
Con
Þ
gures the maximum duration of a conference. (Default = 240 minutes)
●
End Tone Alert Time
Con
Þ
gures the time that the end alert message is played. (Default = 6 minutes)
●
Use Custom Greeting
When enabled (by selecting the check box) the Conference Bridge will play the recorded personalized
greeting. When disabled (unchecking the box), 16CNFU restores the factory default greeting.
●
Recording Personalized Greeting:
1. Dial into one of the 16CNFU extensions and enter the set code for recording a
Personalized greeting.
PASSWORD: 243939#
Use Program 10-03-02 PCB Setup and enter the slot number of 16CNFU PCB
to verify which ports are used (example: If the 16CNFU has been placed into slot 6,
the phone displays:
10-03-02 = Slot No 6
ESI port 01 CH1 TEL 33
Port 33 [Extension 333] is the
Þ
rst port assigned to the 16CNFU. Dial Extension
333 to dial into the 16CNFU PCB.
2. Listen to the series of prompts played to guide you through recording your personalized
greeting.
The customized greeting is automatically enabled after you accept the newly
recorded greeting.
Clicking on
Submit
sends the changes to the conference application. The con
Þ
guration is saved to non-volatile
memory so it is retained after a reset. Clicking on the
Cancel
button returns the user to the
Administration
page.