www.DataSheet4U.com
CHAPTER 15 SERIAL INTERFACE CHANNEL 0 (
µ
PD78014 Subseries)
303
(6) Address match detection method
In the SBI mode, a particular slave device can be selected by sending a slave address from the master device.
Address match detection is automatically executed by hardware. With the slave address register (SVA), and
if the wake-up function specification bit (WUP) = 1, CSIIF0 is set only when the selve address transmitted from
the master device matches the value set in SVA.
If bit 5 (SIC) of the interrupt timing specification register (SINT) is set to 1, the wake-up function dose not operate
even with WUP = 1 (an interrupt request signal is generated in detecting a bus release). When the wake-up
function is used, clear SIC to 0.
Cautions
1. Slave selection/non-selection is detected by matching of the slave address received after
bus release (RELD = 1).
For this match detection, match interrupt request (INTCSI0) of the address to be generated
with WUP = 1 is normally used. Thus, execute selection/non-selection detection by slave
address when WUP = 1.
2. When detecting selection/non-selection without the use of interrupt request with WUP = 0,
do so by means of transmission/reception of the command preset by program instead of
using the address match detection method.
(7) Error detection
In the SBI mode, the serial bus SB0 (SB1) status being transmitted is fetched into the destination device, that
is, the serial I/O shift register 0 (SIO0). Thus, transmit errors can be detected in the following ways:
(a) Method of comparing SIO0 data before transmission to that after transmission
In this case, if two data differ from each other, a transmit error is judged to have occurred.
(b) Method of using the slave address register (SVA)
Transmit data is set to both SIO0 and SVA and is transmitted. After termination of transmission, the COI
bit (match signal coming from the address comparator) of the serial operating mode register 0 (CSIM0) is
tested. If it is “1”, normal transmission is judged to have been carried out. If it is “0”, a transmit error is judged
to have occurred.
Содержание 78014Y Series
Страница 2: ...www DataSheet4U com 2 MEMO...
Страница 8: ...www DataSheet4U com 8 MEMO...
Страница 22: ...www DataSheet4U com 22 MEMO...
Страница 30: ...www DataSheet4U com 30 MEMO...
Страница 34: ...www DataSheet4U com 34 MEMO...
Страница 62: ...www DataSheet4U com CHAPTER 2 OUTLINE PD78014Y Subseries 62 MEMO...
Страница 78: ...www DataSheet4U com CHAPTER 3 PIN FUNCTION PD78014 Subseries 78 MEMO...
Страница 94: ...www DataSheet4U com CHAPTER 4 PIN FUNCTION PD78014Y Subseries 94 MEMO...
Страница 170: ...www DataSheet4U com CHAPTER 7 CLOCK GENERATOR 170 MEMO...
Страница 222: ...www DataSheet4U com CHAPTER 9 8 BIT TIMER EVENT COUNTER 222 MEMO...
Страница 230: ...www DataSheet4U com CHAPTER 10 WATCH TIMER 230 MEMO...
Страница 262: ...www DataSheet4U com CHAPTER 14 A D CONVERTER 262 MEMO...
Страница 318: ...www DataSheet4U com CHAPTER 15 SERIAL INTERFACE CHANNEL 0 PD78014 Subseries 318 MEMO...
Страница 408: ...www DataSheet4U com CHAPTER 16 SERIAL INTERFACE CHANNEL 0 PD78014Y Subseries 408 MEMO...
Страница 446: ...www DataSheet4U com CHAPTER 17 SERIAL INTERFACE CHANNEL 1 446 MEMO...
Страница 472: ...www DataSheet4U com CHAPTER 18 INTERRUPT FUNCTIONS AND TEST FUNCTION 472 MEMO...
Страница 502: ...www DataSheet4U com CHAPTER 22 PD78P014 78P014Y 502 MEMO...
Страница 520: ...www DataSheet4U com CHAPTER 23 INSTRUCTION SET 520 MEMO...