neat
27
NE41 11014-02 v4.1
WALL - Technical Handbook
Bild 19.
Default configuraton directory.
5.5 Communication menu - WIOR Category
Picture 20.
Communication menu.
5.5.1 Read from/write to device
To read/write configurations, follow this general procedure:
1. Connect NPU to USB port and power adaptor.
2. Insert a jumper on J1 in the device.
3. Insert batteries (2xAAA) or connect 10-24V to screw terminals 7 and 8 in the device.
4. Click
Communication|Read from/Write to device
to start the configuration session.
5. Select device name, serial number (found on the data label on the PCB. In this
example serial #0426 is used) and primary frequency band.
Picture 21.
Enter serial number for requested device.