NE41 17030-02 v1.0
D-POS II
- Technical Handbook
neat
27
Appendix A Technical data
Appendix A.1 D-POS Parts
These are the article numbers for standard products. Deviations may occur for
customized kits and/or customers.
Denomination
Article number
D-POS II Kit, Standard
NE10 17003-01
Mounting frame, 1 mm
NE32 11003-04
Mounting frame, 13 mm
NE32 11003-05
Appendix A.2 D-POS II Unit
Denomination
Data
Dimensions (W x H x D)
86 x 86 x 26 mm
Weight
85 g
Supply voltage
12-28 V
DC,
1,6 A (See table Table 13 for
approved AC/DC adaptors.)
Current consumption
Standby = 25 mA, Max = 1,5 A
Frequency
RF
- EU
869.2 MHz, Social alarms
Frequency
RF
- Non EU*
866.2, 868.2, 906.2, 916.2 MHz
* According local regulations for social alarms
Door codes
<=65000
RFID power steps
32
Loop resistance
max
1 kΩ
Working temp
5-35
o
C
Output #9, #10
Resistance
max
(Closed)
2 Ω
Blocking voltage
max
60 V
DC
Load current
max
400 mA
Leakage current
max
(Open)
1 μA
Isolation voltage
1500 V
DC
Table 12.
D-POS II technical data