DOOR
Door Alarm
User Guide
Страница 1: ...DOOR Door Alarm User Guide ...
Страница 2: ...Overview 4 5 Installation 6 Mounting Instructions 7 External Sensor Wiring 7 Functionality 7 Alarm Delay at In Passage 8 Alarm Delay at Out Passage 8 Configuration 8 Special Functions 9 Connect DOOR to Portable Receiver TREX 10 Connect DOOR to Home Care Phone NEO 10 Declaration of Conformity 11 ...
Страница 3: ...ames lit tobacco products or temperatures above 60 C This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Instead it shall be returned to NEAT Electronics for recycling The recycling of materials will prevent negative consequences for the environment human health and help to conserve natural resources ...
Страница 4: ...4 magnet center mark Overview power switch LED magnet adhesives for mounting on door or wall magnet shall be within this area then door is closed ...
Страница 5: ...5 Overview connector for external sensor close lid using supplied screw batteries jumper mounting holes ...
Страница 6: ...wn on page 8 3 Close the cover and fit the screw as shown on page 5 Mount the door alarm as described on the next page 4 If an external sensor shall be used such as a a bed alarm or a carpet sensor insert the cable from the sensor to the connector on the botton short side of the door alarm 5 Turn on the power switch 6 Connect the door alarm to an alarm receiver as described on page 10 in this manu...
Страница 7: ...nother two seconds Note If the in passage delay is enabled the LED first blinks during five seconds before an alarm is transmitted Mounting Instructions The door alarm can be mounted on a door and the magnet on the door frame or vice versa The magnet can be placed on either side of the door alarm The distance between door alarm and magnet must not be more than one centimeter when the door is close...
Страница 8: ...n care personnel leaves the room the power switch must be turned on again Out Passage Delay If the out passage delay is enabled DOOR does not react to the door being opened during the first five seconds after the power switch on DOOR is turned on This allows care personnel to leave the room without an alarm being sent Configuration The in and out passage delay can be enabled by fitting the jumper ...
Страница 9: ...he auto reset time no alarm will be sent This function is useful for example with a bed sensor connected to DOOR The patient can then go to the toilet without an alarm being sent as long as he returns to bed within a certain time Peek Function With a carpet sensor connected to DOOR and the peek function enabled the door can be opened without any alarm being sent as long as the patient is standing ...
Страница 10: ...REX Connecting DOOR to Home Care Phone NEO Receiver position 5 in NEO is standard for door alarms To program alarms from DOOR into position 5 in NEO perform the following steps 1 Press and hold the grey button on NEO while switching NEO on 2 Wait until five beeps are heard then release the button 3 Open the door that the door alarm is mounted on 4 The LED on DOOR lights up with a steady red light ...
Страница 11: ...responsibility that our product DOOR NE10 07028 01 is in conformity with the directives 1999 5 CE 73 23 CE and 89 336 CEE and conforms to the standards Safety EN 60950 1 2001 EMC EN 301489 3 v1 4 1 Class I Radio EN 300220 3 v1 1 1 Löddeköpinge February 2008 Lars Nyström Managing director NEAT Electronics AB ...
Страница 12: ...www neatelectronics com NEAT Electronics AB Varuvägen 2 246 42 Löddeköpinge SWEDEN ...