- ORIGINAL INSTRUCTIONS -
ADJUSTMENTS
POTENTIOMETER ADJUSTMENTS TRAVERSE DRIVE CONTROL (TDC)
Min. Speed--Factory set at full (CCW) 8:30. Do not change this setting.
(Right Traverse) Forward Torque--Factory set at full (CW) 4:30. Do not change this setting.
(Left Traverse) Reverse Torque--Factory set at full (CW) 4:30. Do not change this setting.
IR COMP--Factory set to 9:00. IR COMP is current (I) resistance (R) compensation (COMP). IR COMP adjusts
the output voltage of the drive which balances load to motor RPM. Regulation of a traverse motor may be
improved by slight adjustment of the IR COMP pot clockwise from its factory-set position. Overcompensation
causes the motor to oscillate or to increase speed when fully loaded. If you reach such a point, turn the IR
COMP pot
counterclockwise until the symptoms disappear.
Max. Speed--Set at 3:30 for maximum voltage of 90 Volts DC to the traverse motor. When voltage is above 90
volts DC, the traverse motor will start to pulsate and not run smoothly.
(Right Traverse) Forward Acceleration--Factory set at full (CCW) 8:30. Do not change this setting.
(Left Traverse) Reverse Acceleration--Factory set at full (CCW) 8:30. Do not change this setting.
(DB) Dead Band is the potentiometer setting for the 50 or 60 Hz cycle control. Factory set to 9:00, works for
both 50 and 60 Hz. Do not change this setting.
Calibrating the
DWELL TIME
rotary DIP switch adjusts the amount of time the process remains in the stop
position after a limit switch is actuated. The
DWELL TIME
range is adjustable from 0-4 seconds. A DIP switch
setting of 0 sets the
DWELL TIME
to 0 seconds, while a setting of 9 sets the
DWELL TIME
to 4.5 seconds. Dwell
time is preset to #4 setting for a 2 second dwell time when reversing at each end of stroke. A setting of 6, sets
the dwell time at 3 seconds, etc.
Diagnostic LED's indicate the function that is currently being performed:
POWER indicates that AC power is being applied to the control.
FORWARD indicates that the process is running in the forward direction
(traversing left).
REVERSE indicates that the process is running in the reverse direction
(traversing right).
PROX 1 FWD LIMIT lights when the forward limit switch is actuated (left prox.).
PROX 2 REV LIMIT lights when the reverse limit switch is actuated (right prox.).
DWELL lights when the process remains stopped after a proximity switch is actuated.
Potentiometer
Clock Orientation
FIG. 16
Содержание 181
Страница 37: ...37 ORIGINAL INSTRUCTIONS ...
Страница 42: ...42 ORIGINAL INSTRUCTIONS PARTS LIST 18518 CROSS SLIDE ASSEMBLY ...
Страница 44: ...44 ORIGINAL INSTRUCTIONS PARTS LIST 27554 CHANNEL TRAVEL ...
Страница 46: ...46 ORIGINAL INSTRUCTIONS PARTS LIST 18504 CARRIAGE ASSEMBLY ...
Страница 48: ...48 ORIGINAL INSTRUCTIONS PARTS LIST 18520 GRINDING HEAD ...
Страница 50: ...50 ORIGINAL INSTRUCTIONS PARTS LIST 6059550 INDEX FINGER ASSEMBLY ...
Страница 52: ...52 ORIGINAL INSTRUCTIONS PARTS LIST 6009523 SPIN DRIVE ...
Страница 54: ...54 ORIGINAL INSTRUCTIONS PARTS LIST 6009527 REEL SET UP GAUGE ASSEMBLY ...
Страница 56: ...56 ORIGINAL INSTRUCTIONS PARTS LIST 18535 CONTROL PANEL ASSEMBLY ...
Страница 58: ...58 ORIGINAL INSTRUCTIONS PARTS LIST 18534 ELECTRICAL PANEL SUB ASSEMBLY ...
Страница 62: ...62 ORIGINAL INSTRUCTIONS PARTS LIST 18558 WINCH BOOM ...
Страница 64: ...64 ORIGINAL INSTRUCTIONS 18437 WIRING DIAGRAM ...
Страница 65: ...65 ORIGINAL INSTRUCTIONS ...
Страница 66: ...66 ORIGINAL INSTRUCTIONS WIRING SCHEMATIC ...