NEAR 6XL Скачать руководство пользователя страница 2

CAUTION: TO PREVENT THE RISK OF ELECTRIC

SHOCK, DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE. REFER

SERVICING TO QUALIFIED PERSONNEL.

The lightning flash with arrow-
head symbol, within an equilater-
al triangle, is intended to alert the
user to the presence of uninsu-
lated “dangerous voltage” within
the product’s enclosure that may
be of sufficient magnitude to con-
stitute a risk of electric shock to
persons.

The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and mainte-
nance (servicing) instructions in
the literature accompanying the
appliance.

Every effort was made to ensure that the information in this
guide was complete and accurate at the time of printing.
However, information is subject to change.

WARNING:

To Reduce The Risk of Fire Or Electric Shock,

Do Not Expose This Apparatus To Rain Or Moisture.

Always follow these basic safety precautions when
installing and using the unit:

1.

Read these instructions.

2.

Keep these instructions.

3.

Heed all warnings.

4.

Follow all instructions.

5.

DO NOT use this apparatus near water. The apparatus
shall not be exposed to dripping or splashing and no
objects filled with liquids, such as vases, shall be
placed on the apparatus.

6.  Clean only with dry cloth.

7.

DO NOT block any ventilation openings. Install in 
accordance with the manufacturer’s instructions.

8.

DO NOT install near any heat sources such as radia-
tors, heat registers, stoves, or other apparatus (includ-
ing amplifiers) that produce heat.

9.

DO NOT defeat the safety purpose of the polarized or
grounding-type plug.  A polarized plug has two blades
with one wider than the other.  A grounding-type plug
has two blades and a third grounding prong. The wide
blade, or the third prong, are provided for your safety.
If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.

10. Protect the power cord from being walked on or

pinched, particularly at plugs, convenience recepta-
cles, and the point where they exit from the apparatus.

11. Only use attachments/accessories specified by the

manufacturer.

12. Unplug this apparatus during lightning storms or when

unused for long periods of time.

13. Refer all servicing to qualified service personnel.

Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normal-
ly, or has been dropped.

NOTICE

IMPORTANT

IMPORTANT SAFETY INFORMATION

Содержание 6XL

Страница 1: ...Model 6XL Power Amplifier Installation and Use Manual 2014 Bogen Communications Inc All rights reserved 54 2224 01A 1402 ...

Страница 2: ...th liquids such as vases shall be placed on the apparatus 6 Clean only with dry cloth 7 DO NOT block any ventilation openings Install in accordance with the manufacturer s instructions 8 DO NOT install near any heat sources such as radia tors heat registers stoves or other apparatus includ ing amplifiers that produce heat 9 DO NOT defeat the safety purpose of the polarized or grounding type plug A...

Страница 3: ...el 3 INSTALLATION 4 5 Mechanical Components 4 Ventilation 5 Rack Mounting 5 Rear Rack Mounting 5 Table Mounting 5 CONNECTIONS 6 Speakers 6 Inputs 6 OPERATION 7 Front Controls Indicators 7 Rear Controls Indicators 7 TROUBLESHOOTING 8 SPECIFICATIONS 9 LIMITED WARRANTY EXCLUSION OF CERTAIN DAMAGES 10 ...

Страница 4: ...iii This Page Left Intentionally Blank ...

Страница 5: ...ed outside of the forced air stream flow Front mounted fan filters provide easy removal and cleaning The 6XL amplifier has a variety of electronic protection circuits including overcur rent DC voltage and thermal circuits A special Clip Limiting circuit continuously monitors the amount of distortion in the output signal and reduces input levels as the amplifier approaches clipping Back Slope AC Vo...

Страница 6: ...ssive signal levels or very low imped ance output loads cause output distortion to exceed a few percent Under such conditions a built in Clip Limiting circuit activates and reduces input signal levels to protect both amplifier and speaker loads One for each channel 4 Power Switch Circuit Breaker Magnetic circuit breaker switch controls AC power to the amplifier 5 Fan Air Intake and Grilles Air int...

Страница 7: ...ut channel 6 Fan Exhausts Cooling air outlets for independent variable speed cooling fans One per channel 7 Line Cord AC mains line cord 8 Automatic Sleep Mode Allows the unit to automatically put itself into sleep mode when there has been no input signal for more than 3 minutes In sleep mode the amplifier s idle power is greatly reduced The amplifier immediately and noiselessly returns to its ful...

Страница 8: ...e is a noticeable build up of dust on the filters To clean the filters remove them from the grilles and wash vacuum or tap them out Promptly replace them Caution The fan blades are accessible when the grille cover and filter are removed Be careful not to place your finger or other objects into the fan 3 Fan Grille To attach the fan grilles first slide the tabs on the wider end of the grille A in t...

Страница 9: ... ears are included with the amplifier to allow mounting in 19 racks Attach the rack ears as shown in the Mechanical Components section If any feet have been attached to the bottom of the amplifier remove them Load the amplifier into the rack and secure it to the rack with appropriate hardware not included Rear Rack Mounting Optional accessory not included For greater rear support when rack mountin...

Страница 10: ...d Terminal is provided as a convenient means to connect to the amplifier s chassis AC ground if necessary DO NOT connect the earth ground terminal to the terminals of either output No damage will occur if this is accidently done but the amplifier will go into protect mode and shut down the affected channel Speakers Balanced Input Connections Balanced input connections are used when the source devi...

Страница 11: ...on the 6XL amplifier to adjust output volume of each channel independently Sleep Switch The amplifier includes a sleep mode feature that greatly reduces the power con sumption of the amplifier after it has been idle no audio activity for more than 3 minutes Any audio activity present at the input will power up the amplifier instantaneously and noiselessly so that there is no loss of audio The slee...

Страница 12: ...ED SOUND INTERMITTENT OPERATION Status LED is Green Signal LED is off Level Controls Turned Down No Signal from Source Input Not Set or Wired Properly Status LED is Green Signal LED is Green Limit LED is off Status LED is Green Signal LED is Green Limit LED is off Input Signal Level Too High Poor Speaker Connections Filter Switch Not Set Correctly Status LED is Green Signal LED is Green Limit LED ...

Страница 13: ...RF 50k ohm unbalanced RCA Filter 85 Hz 2nd order roll off High Pass Low Pass switch selectable per channel AC Current Rating full power 20A AC Voltage 120V AC 60 Hz Indicators Status Limit Signal Cooling Dual independent Forced Air Variable Speed Fan Dimensions W x H x D 17 W x 3 1 2 H x 18 1 4 D Product Weight 46 lb Protection R F DC Low frequency Thermal Low impedance Circuit Breaker Short Circu...

Страница 14: ...r supplying of NEAR products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF THE MANUFACTURE SALE OR SUPPLYING OF NEAR PROD UCTS EVEN IF BOGEN...

Страница 15: ...Notes ...

Страница 16: ...NEAR is a Division of Bogen Communications Inc 50 Spring Street Ramsey NJ 07446 USA Tel 201 934 8500 www bogen com www nearspeakers com ...

Отзывы: