background image

 12

SCS4, SCS8 - LITHIUM PHASES DISCUSSION

PRELIMINARY CHECK

Battery status Check. 

Charge will not start with voltage under 2.0V 

and more then 14V

RESCUE

For  deeply  discharged  battery:  current  will 

be 200-400

m

A at 13,8V until voltage   will be 

>11,5V (2 hours max timeout)

CHECK

If battery voltage

10.8V, smartcharger move 

to next step

BULK CHARGE

If battery level has reached 13.8V. A constant 

current  (SCS4:  4A,  SCS8:  8A)  will  charge  the 

battery when the current reduces to 0,8A

ABSORPTION 

CHARGE

If  battery  level  is  between  13.8V-14.4V, 

Smartcharger will switch to Constant voltage 

mode:  output  current  will  automatically 

adjust  as  according  to  the  raise  of  battery 

voltage.  The  charge  will  stop  at  14.4V. 

Smartcharger  will  turn  on  the  Full  charge 

icon led if the current reduces to 0,8A

FINAL CHECK

Battery  voltage  is  monitored  for  1  minute.  If 

voltage  has  a  dramatic  drop  down  under 

12.2V,  the  battery  will  be  classified  as 

exhausted  and  the  error  led  will  turn  on.  If 

voltage can be retained at 1 minute, then the 

Maintenance mode will start

MAINTENANCE

Battery maintained at 13,8V to be kept always 

ready to go. Routine is: 2 minutes charge and 

2 minutes pause for 12 hours, then stop. 

If voltage drops below 13,3V, the 

maintenance mode routine will restart. 

If voltage drops below 12V, the smartcharger 

will restart from bulk charge

NOTE 

THE red DOTTED box                                     underlines the whole rescue 

mode  section  that  is  activated  only  in  case  of  battery  low 

performances. 

Содержание SMARTCHARGER SCS2

Страница 1: ...1 SMARTCHARGER User manual Valid for the following models SCS2 SCS4 SCS8 ...

Страница 2: ...he European Directive 2012 19 EU According to the local waste disposal rules do not dispose of old products with normal household waste The proper disposal of products that can no longer be used prevents potential negative consequences for the environment and for the population ...

Страница 3: ...INDEX 1 Introduction 2 2 Contents of the pack 3 3 main features 4 4 Preliminary process 4 5 Installation 5 6 Start the charge 6 7 Charging curves 9 8 Technical features 13 9 warranty 15 ...

Страница 4: ...paper cloth etc Do not cover the cooling slits on the side and the fan on the top Do not install the device near wet batteries they produce flammable corrosive and explosive gas while working and it can damage the product Protect the device from sunlight or direct sources of heat To avoid malfunctions DO NOT install and use the device in very humid environments in contact with water splashes vario...

Страница 5: ...o make changes and improvements to the product at any time without notice and without obligation to apply these changes to the devices previously distributed The images of the products are purely indicative and may therefore not be fully representative of the characteristics of the product differing in color size or accessories 2 Contents of the pack Check the package contents N 1 SMARTCHARGER N 1...

Страница 6: ...stilled water in each cell until battery acid reaches level specified by battery manufacturer Do not overfill 4 Before to start always remove grounded connection from battery and Make sure all the appliances in the vehicle are off 5 Be sure that the area around battery is well ventilated while battery is charging 4 CAUTION To charge an engine battery directly inside the vehicle connect the negativ...

Страница 7: ...tion polarity on the battery poles will stop the charge and SMARTCHARGER will light up the error led 2 CONNECT SMARTCHARGER TO AC POWER SOCKET 3 IF POWER INDICATOR LED IS ON SMARTCHARGER IS READY TO CHARGE 4 SET THE CORRECT CHARGING CURVE PRESSING THE MODE BUTTON SCS4 SCS8 The Charging curve depends on battery technology and specifications See the curve description at Page 9 5 AGM LITHIUM LiFePO4 ...

Страница 8: ...u let immediately understand the selected charging parameter and the running charge step 6 12V 2A SMART CHARGER SCS2 FULL CHARGING MODE AGM LITHIUM LiFePO4 SMARTCHARGER SCS8 12V 8A SCS2 SCS4 SCS8 AGM LITHIUM LiFePO4 SMARTCHARGER SCS4 12V 4A MODE ...

Страница 9: ...t during charge Power status Led Error Led short circuit reverse polarity bad battery Rescue mode Battery is Charging Full charge maintenance mode on Bike battery charging curve Car battery charging curve AGM batteries Cold temperature charging curve Lithium LiFePO4 battery charging curve AGM LITHIUM LiFePO4 MODE NOTE If the ac power socket is connected before connecting the clamps to the battery ...

Страница 10: ...the battery SMARTCHARGER will try to recover it and the rescue led will light up Rescue can take 30 to 120 minutes Charge will turn to normal charge step 5 when the battery is recovered If battery can t be recovered the error led will be light up 5 If everything is ok the charge will start and the charging led will light up 6 The full charge maintenance led will light up when the battery is fully ...

Страница 11: ...am auto moto AGM batteries lithium batteries suitable for auto and motor vehicle SMARTCHARGER SCS8 4 different charging program auto moto AGM lithium suitable for auto and motor vehicle RV marine truck 9 14 4V 1A 14 4V 4A 14 7V 4A 14 4V 4A AGM LITHIUM LiFePO4 14 4V 2A 14 4V 8A 14 7V 8A 14 4V 8A AGM LITHIUM LiFePO4 NOTE If the Lithium battery LiFePO4 is deeply discharged and the function UVP under ...

Страница 12: ...he voltage reaches 14 4V Smartcharger will turn on the Full charge icon led when current is 0 8A SCS2 CHARGING CURVE SCS4 SCS8 CHARGING CURVE BATTERY VOLTAGE CHARGING CURRENT 6V BULK CHARGE ABSORPTION CHARGE PRELIMI NARY CHECK 2V RESCUE SOFT START PULSE CHARGE RECONDI TIONING BULK CHARGE ABSORPTION CHARGE FINAL CHECK MAINTE NANCE PRELIMINARY CHECK BATTERY VOLTAGE CHARGING CURRENT ...

Страница 13: ... BULK CHARGE If battery level has reached 12 0V 13 6V A constant current will charge the battery until it has reached 80 of the capacity SCS4 1A motorcycle mode 4A car mode 4A AGM mode SCS8 2A motorcycle mode 8A car mode 8A AGM mode ABSORPTION CHARGE If battery level is between 13 6V 14 4V 14 7V for agm Smartcharger will switch to Constant voltage mode output current will automatically adjust as a...

Страница 14: ...according to the raise of battery voltage The charge will stop at 14 4V Smartcharger will turn on the Full charge icon led if the current reduces to 0 8A FINAL CHECK Battery voltage is monitored for 1 minute If voltage has a dramatic drop down under 12 2V the battery will be classified as exhausted and the error led will turn on If voltage can be retained at 1 minute then the Maintenance mode will...

Страница 15: ...voltage 6V Battery charge capacity 3 40Ah Battery maintenance Up to 80Ah Protection IP65 SMARTCHARGER SCS4 Input rated voltage 220 240V Input rated current 0 45A Output rated voltage 12V Output charging current 1 4A 14 4V 1A 14 4V 4A 14 7V 4A 14 4V 4A Charging curves AGM Wet Lithium Charging method 9 steps Activation voltage 2V Battery charge capacity 5 80Ah Battery maintenance Up to 100Ah Protect...

Страница 16: ...A Output rated voltage 12V Output charging current 2 8A 14 4V 2A 14 4V 8A 14 7V 8A 14 4V 8A Charging curves AGM Wet Lithium Charging method 9 steps Activation voltage 2V Battery charge capacity 10 160Ah Battery maintenance Up to 250Ah Protection IP65 AGM AGM LITHIUM LiFePO4 ...

Страница 17: ... 4470396 fax 39 085 9112263 STAMP AND SIGNATURE OF THE SELLER WARRANTY COUPON 24 MONTHS MODEL_________________________________________________________________________ SERIAL NUMBER________________________________________________________________ PURCHASE DATE_______________________________________________________________ ...

Страница 18: ...16 ...

Страница 19: ...17 ...

Страница 20: ... L ENERGIA CHE TI SERVE 0053_MANU_SmartCh_GB01 NDS ENERGY s r l Via Pascoli 169 65010 Cappelle sul Tavo Pe Italy Tel 39 085 4470396 Fax 39 085 9112263 Web www ndsenergy it Email customer ndsenergy it LIKE US facebook com ndsenergysrl ...

Отзывы: