background image

iii 

National Display Systems, Inc. (hereinafter "NDS") warrants this product to be free from defects in material and workmanship 
and, subject to the conditions set forth below, agrees to repair or replace any part of the enclosed unit other than the LCD 
backlight, which proves defective for a period of three (3) years from the date of first purchase or 10,000 hours of operation 
whichever comes first.  Spare parts are warranted for ninety (90) days. 

 

This warranty is limited to the original purchaser of the product and is not transferable.  This warranty covers only NDS supplied 
components.  Service required as a result of third party components is not covered under this warranty.    Proof of Purchase will 
be required by NDS to substantiate date of purchase.  Such proof of purchase must be an original bill of sale or receipt 
containing the name and address of the seller and the purchaser and the serial number of the product. 

 

It shall be your obligation and expense to have the product shipped, freight prepaid, or delivered to the authorized reseller from 
whom it was purchased, or other facility authorized by NDS to render services provided hereunder, in the original package. All 
products returned to NDS for service MUST have prior approval  which may be obtained by contacting the factory. The product 
shall not have been previously altered, repaired, opened or serviced by anyone other than a service facility authorized by NDS to 
render such service.  The serial number of the product shall not have been altered or removed.  In order to be covered by this 
warranty, the product shall not have been subjected to displaying of fixed images for long periods of time, resulting in image 
persistence (afterimage effects), accident, misuse or abuse or operation contrary to the instructions contained in the User's 
Manual.  Any such conditions will void this warranty. 

 

NDS SHALL NOT BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL OR OTHER TYPES OF 
DAMAGES RESULTING FROM THE USE OF ANY NDS PRODUCT OTHER THAN THE LIABILITY STATED ABOVE.  
THESE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 
PARTICULAR PURPOSE.   

 

The product is warranted in accordance with the terms of this limited warranty.  Consumers are cautioned that system 
configuration, software, the application, customer data and operator control of the system, among other factors, affect the 
product performance.  While NDS products are considered to be compatible with many systems, specific functional 
implementation by the customers of the product may vary.  Therefore, suitability of a product for a specific purpose or 
application must be determined by consumer and is not warranted by NDS. 

FCC and Council Directives of European Standards: 

This device complies with Part 15 of FCC rules and 93/42/EEC of the Council Directives of European Standards. Operation is 
subject to the following two conditions:  (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesirable results.  
1.

Use the attached specified cables with the color monitor so as not to interfere with radio and television  reception.  Use of 
other cable and adapters may cause interference with other electronic equipment. 

2.

This equipment has been tested and found to comply with the limits pursuant to FCC part 15 and CISPR 11.  This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 

 

IEC: 

This equipment has been tested and found to comply with the limits for medical devices to the IEC 60601-1-1:2001. These limits 
are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to other devices in the vicinity.  
 

FCC, Council Directives of European Standards and IEC: 

There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

Declarations of Conformity 

 

Limited Warranty

 

Accessory equipment connected to this monitor must be certified according to the respective IEC Standards (i.e., IEC 60950-1 
for data processing equipment and IEC 60601-1 for medical equipment). Furthermore, all configurations shall comply with the 
system standard, IEC 60601-1-1. Anyone  who connects additional equipment to the signal input part or signal output part 
configures a medical system, and is therefore responsible that the system complies with the requirements of system standard IEC 
60601-1-1. Whoever is responsible for securing the monitor to a system needs to insure that the mounting equipment used with 
this display complies to IEC standard 60601-1. If in doubt, consult the technical services department or your local representative.  

Содержание EndoVue SC-SX19

Страница 1: ...EndoVue Surgical Displays E N G L I S H Desk Top or Wall Mount ...

Страница 2: ......

Страница 3: ... Menu Systems Overview 5 Video Source 6 Display Set Up 7 SDI Picture Menu 7 S Video Picture Menu 7 Composite Picture Menu 7 VGA Picture Menu 8 RGBS YPbPr Picture Menu 8 Color Menus 9 Setup Menu 10 Defaults Menu 11 Tab 6 Troubleshooting 12 Tab 7 Drawing and Dimensions 13 EndoVue 15 13 EndoVue 19 14 Tab 8 Data Connectors and Pin Outs 15 Power Connector and Pin Out 16 24 Volt Extension Cable 16 Tab 9...

Страница 4: ...rnal electrical power source for class 1 equipment It is the responsibility of the installer to test the display s earth ground to verify that it complies with the hospital local and national impedance requirements A ground post located on the back of the display may be used for the purpose of grounding the display s chassis Any such ground must be installed in accordance with applicable electrica...

Страница 5: ... purpose or application must be determined by consumer and is not warranted by NDS FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC of the Council Directives of European Standards Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received i...

Страница 6: ...ferences should familiarize themselves before utilization in a critical application and determine its usability For mission critical applications we strongly recommend that a replacement unit be immediately available Powering On The Unit Connect the power supply to the display via the power plug Plug in the AC adapter Connect the video source to the EndoVue display Apply power to the peripheral de...

Страница 7: ...et the REDRIVE switch to Off when the RGBS VGA and YPbPr signals will not be daisy chained to another display The REDRIVE switch is set to On when the RGBS VGA or YPbPr signals will be daisy chained to a second display Electrical Symbols Open Off Switch This symbol appears on the open or off side of the display s rocker switch Closed On Switch This symbol appears on the closed or on side of the di...

Страница 8: ...3 Display Mounting to Stand Attach the stand to the display using the four supplied thumbscrews Note Display Stand is an optional accessory Order Part Number 26B0063 ...

Страница 9: ...or too low causes loss of some grayscales Color saturation may appear incorrect Press the Brightness Contrast button three times to display the Backlight control Press the or button to set the backlighting Note Lowering the backlight level will increase the backlight lifetime Adjust Backlight Adjust Brightness Adjust Contrast Image Adjustments The EndoVue displays are controlled via a 6 button key...

Страница 10: ...u displayed Press the or button to select the menu you want to work with then press the SCROLL button to select the parameter Press the or button to set the parameter to the desired value Press the MENU button to save your changes and close the Menu System Notes 1 All parameter names change to the language selected in the Setup Menu 2 Grayed out parameters are not accessible 3 SDI is not available...

Страница 11: ...menu shows selected to the right of the active input Press the SCROLL button to highlight the desired input Finally press the button to select it To select RGBS VGA YPbPr Scroll to the RGBS VGA YPbPr input and press the button to select the input Finally press the button to toggle between RGBS VGA YPbPr The inactive input is grayed out Notes 1 The display s internal logic determines if an applied ...

Страница 12: ...een without losing video information on Stretches picture horizontally and vertically to fill the screen but does not change its aspect ratio Some video information may be lost Picture may have black bars top and bottom or left and right Select using or buttons Video Format auto Automatically sets the unit to the format of the connected video source ntsc Sets the unit to accept NTSC video pal Sets...

Страница 13: ...not be accurately displayed Aspect Expands the video image until its largest dimension fills the screen Image may be displayed with black bars on the top and bottom or the left and right 1 1 Displays the video data in its native size and aspect ratio Image may be displayed with black bars on the top and bottom and on the left and right Select using or buttons SmartSync On initialization NDS propri...

Страница 14: ...em PACS is a DICOM like LUT available with VGA Saturation SDI RGBS YPbPr S Video and Composite Press or to set the saturation color intensity of the image Red Green Blue All Press the or button to increase or decrease the intensity of the selected color Hue SDI RGBS YPbPr S Video and Composite Press or to set the hue color tint of the image SDI RGBS YPbPr S Video and Composite VGA ...

Страница 15: ...klight tubes in the display The display turns on when the input signal is restored Press the button to enable DPMS press the button to disable DPMS Auto Source Select on Searches through all possible input sources until an active video source is found off Video input is manually selected Press the or button to disable or enable Auto Source Select Menu Lock Disables access to menu system This preve...

Страница 16: ... Use the SCROLL button to select an available User Defaults EMPTY appears in available User Defaults 4 Press the to save the user s settings The EMPTY message will be removed see User Defaults 1 in the above OSM illustration 5 Repeat steps 1 thru 4 for up to 5 users Restoring User Defaults 1 Select the User Defaults to be restored then press the button Clearing User Defaults 1 Select the User Defa...

Страница 17: ...ge The displayed image may be too wide or too narrow and vertical banding and pixel jitter may appear in grays and light colors Adjust the Frequency until the image just fits the screen Horizontal position adjustment can be used to verify that Frequency is set correctly Line up the image on the left edge of the screen and then shift by one click to the right The image should have one column off th...

Страница 18: ...Drawing and Dimensions 7 13 EndoVue 15 Display Stand is an optional accessory Order Part Number 26B0063 ...

Страница 19: ...14 EndoVue 19 ...

Страница 20: ...10 GND 15 N C RGBS YPbPr 1 RED 6 GND RED 11 ID0 2 GREEN 7 GND GREEN 12 ID1 3 BLUE 8 GND BLUE 13 HORIZ SYNC 4 ID2 9 N C 14 VERT SYNC 5 GND 10 SYNC GND 15 ID3 VGA Note The following cables are available from NDS 1 Flash Upgrade Cable order part number 35Z0009 Serial and or Touch Screen Control Pin Name Description 1 NC 2 RXD Touch Screen Data Receive 3 TXD Flash Upgrade Touch Screen Transmit 4 NC 5 ...

Страница 21: ...hould be constructed of SJT SJTO SJO ST SO STO or equivalent flexible cord per US National Difference Clause 59 1DV Users outside of the U S should adhere to the applicable electrical codes for their country AWG Maximum Length 14 250 ft 76 m 16 150 ft 45 m 18 100 ft 30 m 24 Volt Extension Cables 24 volt connector Pin 1 2 3 24 VDC GND Shield X Y Z Power Connector and Pin Out The cable requires one ...

Страница 22: ...ominal 500 1 600 1 Vertical Freq Hz max 75 75 Bandwidth MHz max 135 135 VGA Input signal level at 75 Ohm 0 7 V p p 0 7 V p p Pixel Clock MHz max 170 170 S Video Input signal level 0 7 V p p 0 7 V p p Composite Input signal level 1 V p p 1 V p p RGBS Input signal level 0 7 V p p 0 7 V p p Sync 0 4 to 4 0 V p p 0 4 to 4 0 V p p Pixel Clock MHz max 140 140 Power Consumption nominal 50w 60w Display We...

Страница 23: ...tible with it Do not allow liquid to enter the display All product names and trademarks or registered trademarks are the property of their respective holders Video Formats Horiz Freq kHz Interlaced Progressive Aspect Standard Digital Analog 576 50i PAL SDI Comp S video RGBS YPbPr 15 625 Interlaced 16 9 4 3 SMPTE 259M C ITU 601 480 60i NTSC SDI Comp S video RGBS YPbPr 15 734 Interlaced 16 9 4 3 SMP...

Страница 24: ...uarters 16245 Vineyard Blvd Morgan Hill CA 95037 Tel 408 776 0085 Fax 408 776 9878 E Mail support nationaldisplay com National Display Systems Europe Nijverheidscentrum 2D 2761 JP Zevenhuizen ZH The Netherlands Tel 0031 180 63 43 56 Fax 0031 180 63 21 91 Part 60A0107 ECO 06 401 Rev C ...

Отзывы: