NDS 90T0007 Скачать руководство пользователя страница 1

User manUal

[ E N g l I s H ]

Asia Pacific Offices

1st Fl., rIse Building, 5-13, 
asakusabashi 5-Chome,
Taito-Ku, Tokyo,  Japan, 111-0053 
Tel: + 81 3 6420 3031
email: [email protected]

OR Informatics System

Содержание 90T0007

Страница 1: ...User manual E n g l i s h OR Informatics System ...

Страница 2: ......

Страница 3: ...roducts from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi NDS Surgical Imaging NDSsi ConnectOR ConductOR Radiance Endovue and SmartSync are either registered or unregistered...

Страница 4: ......

Страница 5: ...20 VGA SOG Picture Menu 21 RGBS YPbPr Picture Menu 21 DVI Picture Menu 22 Color Menu 23 Setup Menu 24 Defaults Menu 24 Tab 8 Utilities 25 Tab 9 Streaming Video Audio 26 Location to Location Network Connections 26 Software Setup 27 Location to Location Transmit Setup 28 Location to Location Receive Setup 29 Location to Location Streaming 32 Streaming Video 35 Streaming Audio 36 Streaming from Condu...

Страница 6: ...lity of the installer to ensure that the equipment is installed in accordance with applicable hospital local and national electrical codes An equipotentiality post located on the back of the equipment may be used for the purpose of bonding the ConductOR s chassis to other equipment to ensure that all devices are at the same potential Any such bond must be installed in accordance with applicable el...

Страница 7: ...ppropriate they reserve all patent copyright and other proprietary rights to this document including all design manufacturing reproduction use and sales rights thereto except to the extent said rights are expressly granted to others FCC and Council Directives of European Standards This device complies with Part 15 of FCC rules and 93 42 EEC of the Council Directives of European Standards Directive...

Страница 8: ...ipment When video source equipment is connected to the ConductOR the end user must verify that video is passed from the video source through the ConductOR and is displayed correctly on the connected monitors External control failure RS 232 communication failure Control unit from front panel touch screen ConductOR cannot be powered on Defective internal power supply Bypass the ConductOR by connecti...

Страница 9: ...h 720p or greater resolution 3 HD displays with HD SDI or 3G SDI input Control Options The ConductOR may be controlled from 1 Its front LCD touch panel 2 A PC via the RS 232 port See page 50 for serial port setup and test details The NDS Unified Serial Commands P N 60A0156 document contains a complete set of serial commands for the ConductOR Please contact your NDS sales representative for details...

Страница 10: ... in receive mode YPbPr OUT outputs the video data that is inbound to the streamer This data may viewed by selecting LAN as the input for the active display See Select Input Screen on page 10 and Primary and Secondary Input Screens on page 11 The DVI D OUT outputs video data from the selected Stream Source See IP Streaming on page 15 6 Audio data is retrieved from the ETHERNET connection converted ...

Страница 11: ...ential Equalization Conductor Power Switch The power switch is push on push off When the switch is off the ring around the center portion is white When the switch is on the center portion is depressed and the ring is illuminated blue The illustration shows the switch in its ON state 4 ...

Страница 12: ... installed in any of the OUT see page 3 card slots in any combination and in any order Up to four output modules may be installed 2 The DVI D and Fiber Optic output modules output signals of 1280 x 720 progressive 1920 x 1080 progressive or 1920 x 1200 progressive at 60Hz Note When a DVI or Fiber Optic output module is selected as the streaming source its output is limited to 1920 x 1080p 3 The 3G...

Страница 13: ...ule Removal Use a number 1 Phillips screwdriver to loosen but not remove the screws located on the left and right sides of the module s mounting plate When the screws are clear of the chassis remove the blank plate or module by gripping the screws and pulling the plate or module out Installation Slide the new module into the chassis until it contacts the connector then push gently until the module...

Страница 14: ...or Fiber USB or RS 232 Touch Screen Control RS 232 Control 1 2 3 4 This monitor displays the same information as monitor 3 PC Video Out 3G SDI DVI or Fiber 3G SDI DVI or Fiber 3G SDI DVI or Fiber DVI Output Displays the video from the selected streaming source ...

Страница 15: ...ower is applied to the ConductOR and is displayed until the ConductOR s Power On Self Test POST finishes The POST takes approximately 20 seconds to complete After the POST finishes the home screen is displayed Home screen is shown on page 9 8 System startup please wait ...

Страница 16: ...uctOR The user may restore the ConductOR s factory defaults or update the scalar firmware Touch this icon to open the Information screen shown on page 14 IP Streaming This screen is associated with network operations and requires a network connection to be effective Touch this icon to open the IP Streaming screen shown on page 15 Output Settings Provides a means to set the output resolution of eac...

Страница 17: ... Touch the Go Back button to return to the home screen Touching the Identify button displays a 1 2 or 3 on the monitor connected to the corresponding output Note As output 4 is slaved to output 3 a 3 will be shown on monitors 3 and 4 The PIP PIP Swap and Disable PIP buttons are described on page 12 Touching the Keypad button opens the Keypad screen and allows access to the ConductOR features that ...

Страница 18: ...put screen is the current input Select a Primary input by touching the button associated with that input To select a secondary input touch the Change button on the Secondary row A grayed out button on the Secondary Input screen may not be selected as a secondary input Touch the Go Back button to return to the Select Inputs screen Empty DVI 2 11 ...

Страница 19: ...nges Each time the PIP button is touched the PIP icon changes as you cycle through the PIP sizes Touch the Swap button to exchange the text in the Primary and Secondary rows The primary and secondary images displayed on the attached monitor are swapped The secondary input may be cleared by touching the Disable PIP button The PIP PIP Swap and Disable PIP buttons are located on the bottom row of the...

Страница 20: ...nu or parameter you want work with The Brightness Contrast button usage is detailed on page 18 Touch the Go Back button to return to the Select Inputs screen Changes made via the keypad are retained when the ConductOR s power is cycled Keypad Screen On the Select Inputs screen page 10 touch the Keypad button to display the Keypad screen To observe the effect of changing an output s parameters a mo...

Страница 21: ... set to 1200 Touch the Go Back button to return to the Home screen Touch the Output Settings icon on the home screen page 9 to display the Display Output Settings screen Information Screen Touch the Information icon on the Home screen page 9 to display the Information screen This screen displays general information about your ConductOR See the screen shot below Touching the Factory Defaults button...

Страница 22: ...isplay 3 to select the output whose data will be sent to the network Set Stream Resolution to 1080i 720p or 480p to match the receiving device s capabilities The IP Address may be set via DHCP default or via the ConfigOR G2 program page 29 The Remote IP address is set using the ConfigOR G2 program page 29 The Start button is used to establish an IP link between two ConductOR s The text in the Remo...

Страница 23: ...econds Displays connected to OUT 3 and OUT 4 will show a 3 On the Select Display row touch the Display 1 icon Display 1 is used for illustration On the Primary row touch the Change button The Primary Input screen is displayed On the Primary Input screen select the input and touch its button The DVI 2 button is used for illustration Touch the Go Back button on the Primary Input screen to return to ...

Страница 24: ...time will restore the inputs to their original locations It is not necessary for both images to be displayed in order to swap primary and secondary images Turn the PIP image off by touching the Disable PIP button page 16 PIP and Swap Selecting a secondary PIP image Touch this button on the Secondary row of the Select Inputs screen page 16 to open the Secondary Input screen shown below Touch the in...

Страница 25: ...its display icon Touch this button to return to the Select Inputs screen page 16 Touch the Brightness Contrast button to display the Brightness control menu Touch the fi or fl button to adjust Primary brightness When a PIP image is visible touch the Brightness Contrast button again to access the Secondary brightness control Setting the brightness too high or too low will decrease the amount of vis...

Страница 26: ...put s primary input is shown in black at the top left of the OSD If there is an active secondary input it will be shown in gray at the top right of the OSD The four available OSD menus are Picture Color Setup Defaults The OSD opens with the Picture menu displayed The menus are shown below Touch the fi or fl button to select the menu you want to work with Touch the SCROLL button to select the param...

Страница 27: ... the sharpness focus of the displayed image Overscan 0 The image is displayed at a size that fills the screen without losing any video information The image presented to the display may include black bars top and bottom or left and right 1 2 3 4 5 or 6 The image is linearly enlarged while remaining centered in incremental steps As the image becomes larger video information will be lost from the to...

Страница 28: ...p and bottom or the left and right of the image 1 1 Displays the video data in its native size and aspect ratio Image may be displayed with black bars on the top and bottom and on the left and right Select using fi or fl buttons Overscan Video This parameter is enabled when the input is video camera data 0 The image is displayed at a size that fills the screen without losing any video information ...

Страница 29: ...or left and right Select using fi or fl buttons Scaling Graphics This parameter is enabled when the input is graphics computer data Fill Expands the video image to fill the entire screen The aspect ratio may not be accurately displayed Aspect Expands the video image without changing its aspect ratio until its largest dimension fills the screen Black bars may be displayed on the top and bottom or t...

Страница 30: ... User allows the individual adjustment of the Red Green and Blue values Red Green Blue Video or Graphic modes Touch the fi or fl button to increase or decrease the intensity of the selected color Saturation Video modes only 2 Touch fi or fl to set the saturation color intensity of the image Hue Video modes only 2 Touch fi or fl to set the hue color tint of the image Notes 1 1024 x 768 1280 x 1024 ...

Страница 31: ... ConductOR Auto Source Select This function is not supported on the ConductOR Menu Lock The menu may be locked via an external control program Operating Hours This function is not supported on the ConductOR BIOS Version of the ConductOR s Scalar firmware Factory Defaults Displays Restoring Factory Defaults message and returns all settings to their factory preset values Touch the SCROLL button page...

Страница 32: ...ng training installation and troubleshooting They may not be used during clinical procedures Place the supplied Integration Software and Users Manual CD 58E0017 in your PC s CD or DVD drive and double click the My Computer icon Double click the 58E0017 icon Double click the ConductOR folder Continued on the following page ...

Страница 33: ...double click its folder Double click the Setup icon Follow the on screen instructions Repeat steps 3 and 4 for each additional software package you want to install E ConductOR 58D0013 B_View OR G2 ViewOR G2 ConfigOR G2 ConductOR Demo E ConductOR ...

Страница 34: ...mmunication Video transmitted from the ConductOR designated as Transmit and video viewed on the ConductOR designated as Receive The audio is bidirectional allowing the staff at each location to converse with each other 9 Connect the ConductOR units to your facility s internal network using Category 5 Ethernet cable Note For clarity only the Network connections are shown in the illustration below S...

Страница 35: ...our IP network and powered on the network will automatically assign it an IP address via its Dynamic Host Configuration Protocol DHCP feature Connect an RS 232 cable from your PC to the ConductOR s RS 232 IN connector Continued on the following pages A DHCP assigned IP address may change if the ConductOR is disconnected from the network and reconnected or if it is turned off ...

Страница 36: ...utton A successful connection will gray out the Connect button fill in the IP Address Subnet Mask and Gateway windows A dot appears in the radio button to the left of Use the following static IP address The message in the lower left corner will change to Connected Close the ConfigOR G2 program Click the radio button to the left of Obtain an IP address automatically You may manually assign the IP A...

Страница 37: ...ose the ConfigOR G2 program Move the RS 232 cable back to the Transmit unit s RS 232 IN connector page 30 Launch the ConfigOR G2 program select the COM port to be used then click the Connect button Type the Receive unit s IP address into the IP Address window in the Remote IP Address frame Optionally the Transmit unit s IP address may be entered in the Receive unit s IP Address window in the Remot...

Страница 38: ...tion 1080i 720p or 480p The IP address is displayed in the IP Address row window should be the same as the IP address that was assigned when you ran the ConfigOR G2 program page 29 Touch the IP Streaming icon on the Receive unit s home screen page 9 When the IP Streaming screen is displayed select Receive on the Mode row Stream Source is disabled in receive mode Stream Resolution will be automatic...

Страница 39: ...32 Touch the Start button The legend on the button changes to Stop The Connecting to screen is displayed When the Connected screen is displayed streaming has started Continued on the next page ...

Страница 40: ... changes to green when an connection is established The Receive unit s Remote IP window remains empty Touch the Stop button to stop streaming data to the Receive unit Note If the Transmit unit s IP address appears in the Receive unit s Remote IP window then streaming may be initiated or terminated from either unit Setting a Remote IP address is described on page 29 Streaming video and audio are de...

Страница 41: ...display On the Home screen page 9 touch the Select Inputs icon Verify that the resolution of the selected output is 1080 See page 14 On the Select Display row touch the Display 1 icon On the Primary row touch the Change button The Primary Input screen is displayed Touch the DVI 2 button Finally touch the Go Back button to return to the Select Inputs screen Verify that DVI 2 appears in the Primary ...

Страница 42: ...the Select Display row touch the Display 1 icon On the Primary row touch the Change button The Primary Input screen is displayed Touch the LAN button Finally touch the Go Back button to return to the Select Inputs screen Verify that LAN appears in the Primary row window An image of the DVI signal applied to the Transmit unit s DVI 2 input page 28 should appear on the display connected to the Recei...

Страница 43: ...e AUDIO OUT connector of both units Speak into the microphone connected to the Transmit unit and you should hear your voice in the headphones connected to the Receive unit Now speak into the microphone connected to the Receive unit and you should hear your voice in headphones connected to the Transmit unit Note An amplifier and a speaker may be substituted for the headphones AUDIO IN is not used ...

Страница 44: ...rgeon performing the procedure may need to consult with one or more colleagues at other locations If the colleagues have a PC Internet connection and ViewOR available they will be able to observe the procedure in real time and provide assistance as needed Transmit HD Video camera ...

Страница 45: ...nit s DVI 2 input Connect the unit s OUT 1 see connector panel on page 3 to a compatible display Finally on the Home screen page 9 touch Select Inputs icon On the Select Display row touch the Display 1 icon Touch the Change button on the Primary row The Primary Input screen is displayed Touch the DVI 2 button An image of the signal applied to DVI 2 should be shown on the connected display Continue...

Страница 46: ...aming icon on the Home screen page 9 to access the IP Streaming screen On the Mode row touch the Transmit button Select Display 1 on the Stream Source row Select 720p on the Stream Resolution row Touch the Go Back button to return to the Home page Continue on the following page ...

Страница 47: ...l be shown in its lower left corner Click the down pull arrow on the right side of the COM Port window and select the COM port to be used Finally click the Connect button A successful connection will gray out the Connect button fill in the IP Address Subnet Mask and Gateway windows The message in the lower left corner will change to Connected Close the ConfigOR G2 program Continue at Using the Vie...

Страница 48: ...he ViewOR G2 icon to launch the program Click the fl button the Open Media window is displayed Click the Open Media window s Network tab Select RTSP from the Protocol pull down menu Type the IP address obtained or entered in the previous section into the Address window Click the Open Media window s Play button Continued on the following page ...

Страница 49: ... It takes up to 15 seconds before an image is displayed Record the video by clicking the record button the record button starts flashing Recording stops when the record button is clicked again Default file name vlc record 2011 03 08 09h28m56s rtsp___192 168 36 208 Header vlc record Time Code 2011 03 08 09h28m56s Protocol rtsp IP Address 192 168 36 208 Click the II button to pause the streaming vid...

Страница 50: ...ppears Call Connected appears when the audio connection is established Place the cursor over the Volume slider hold the left mouse button down and set the volume to the desired level The PC s microphone may be muted by clicking the Microphone button A red ring with a line through it is placed over the microphone icon ...

Страница 51: ... in the User Name window and its password in the Password window Finally click the Add button to save the name and password A single user name may be removed by selecting the name in the User List then clicking the Remove button All user names may be removed by clicking the Remove All button Close the ConfigOR G2 program then turn the ConductOR off and on This writes the names and passwords into t...

Страница 52: ...x 1024 or larger monitor Click the Windows Start button then click All Programs Select NDS Surgical Imaging then select and click DemoOR G2 to launch the demonstration program The program s startup screen is shown below The four right hand primary secondary input labels will be blank until the program is communicating with the ConductOR Click the green button in the lower right corner to start com...

Страница 53: ...stalled Clicking the Identify button displays a 1 2 or 3 in yellow on each of the monitors connected to the ConductOR The monitor connected to OUT 4 will display a 3 The program s Help file may be viewed by clicking the NDS logo The Help file contains a Usage section Controller Scalar and Streamer BIOS part numbers and an inventory of the installed input and output modules Note The Streamer BIOS i...

Страница 54: ...ary input may be selected by clicking one of the Secondary Inputs buttons A graphic showing the size of the secondary PIP window will appear in the active display The size of the PIP window is controlled by the PIP and PIP buttons The Swap button exchanges the Primary and Secondary windows The Clear PIP button turns the PIP window off and clears the secondary input Click this button to exit the pr...

Страница 55: ...a signal connected to it Touch the Select Inputs icon page 9 then on the Select Inputs screen touch the Identify button If the module s ID is displayed on one of the connected displays then select an input that is known to a signal connected to it Output Module is not connected or is connected to wrong display Touch the Select Inputs icon then touch the Identify button If the module s ID is not di...

Страница 56: ...rom a PC connected to the same network as the ConductOR click the start button then select All Programs Accessories Command Prompt 4 Type ping and the IP address from the IP Address window The response should be as shown in the screen shot below Note Your IP address may be different from the IP address in the screen shot No video output Output Module confidence test 1 Turn the ConductOR off 2 Conn...

Страница 57: ... OK Click File click Properties then select ASCII Setup from the Properties menu In the ASCII Setup menu select Echo typed characters locally Click OK to exit ASCII Setup Click OK to exit configuration Click File and select Save to save the configuration Serial Port Test Place the cursor in the text area of the Hyper Terminal window and press Enter 0003C3 is displayed Type 070100078F and press Ent...

Страница 58: ...51 Drawing and Dimensions 11 ...

Страница 59: ...Compliant with DVI 1 0 PIN SIGNAL PIN SIGNAL 1 T M D S DATA 2 16 HOT PLUG DETECT 2 T M D S DATA 2 17 T M D S DATA 0 3 T M D S DATA 2 4 SHIELD 18 T M D S DATA 0 4 T M D S DATA 4 19 T M D S DATA 0 5 SHIELD 5 T M D S DATA 4 20 T M D S DATA 5 6 DDC CLOCK 21 T M D S DATA 5 7 DDC DATA 22 T M D S CLOCK SHIELD 8 ANALOG VERT SYNC Fixed DVI Only 23 T M D S CLOCK 9 T M D S DATA 1 24 T M D S CLOCK 10 T M D S ...

Страница 60: ...X ID N C 4 GND Ground USB Connector Serial Control Pin Name Description 1 NC No Connection 2 RXD Data Receive 3 TXD Data Transmit 4 NC No Connection 5 GND Ground 6 NC No Connection 7 NC No Connection 8 NC No Connection 9 NC No Connection Pin Name Description 1 TX Data Out 2 GND Ground 3 GND Ground 4 Rx Data In RJ 22 Output Module Serial Data Connector 1 ConductOR Display Control Cable 1 2 3 4 3 5 ...

Страница 61: ...ide of the U S should adhere to the applicable electrical codes for their country 24 Volt Extension Cables The cable requires one each of the following connectors Switchcraft SL403F female and Weidmuller BL 3 81 3 See illustrations below Pin 1 2 3 24 VDC GND Shield Switchcraft 403F connector X Y Z Switchcraft SL403F Weidmuller BL 3 81 3 Pin 1 24 Volt Extension Cable Schematic DC Power Connectors a...

Страница 62: ...ound Sleeve Fuse Replacement 1 Disconnect the power cord from the ConductOR 2 Using a small screwdriver at point A pry the Fuse Box out 3 Replace the fuse with a Buss T5AL 250V or equivalent 4 Slide the Fuse Box into its receptacle and press until it seats Fuse Box A ...

Страница 63: ...0p VGA Input signal level at 75Ohms 0 7 V p p HD SDI Input signal level 8 to 2 0 V p p S Video Input signal level 0 7 V p p Composite Input signal level 0 7 V p p Sync On Green SOG 0 7 V p p RGBS Input signal level 0 7 V p p RGBS Input Signal Sync 0 4 to 4 0 V p p Stand Alone Power Consumption nominal 66w3 Power 24 VDC Power Out max 120w System Weight 10 5lbs 4 5 kg Environmental Operating Tempera...

Страница 64: ... 1080 60p RGBS YPbPr DVI SDI 67 300 Progressive 16 9 SMPTE 274M Video and Graphics Inputs Connector Type Composite BNC 75 Ohm terminated VGA Sync On Green SOG HD 15 DVI RGBS YPbPr DVI I Input Modules DVI Input Module DVI D SDI Input Module BNC 75 Ohm terminated Output Modules DVI Output Module DVI D SDI Output Module BNC Fiber Output Module LC S video DIN 4 Fixed Inputs Cleaning Instructions Turn ...