For connexions 01, 02 and 08, it is recommended the use 35mm
2
cross-section cables, if
the length of the connexion is less than or equal to 1 meter. If the length of the connexion
exceeds 1 meter, it is recommended the use of cables with a cross-section of 50mm
2
. It is
also advisable to install a 200A fuse on cables 01 and 08.
Tighten the terminals firmly to screws 1, 2, and 3 of the
3Link
, with the supplied nuts
and washers.
Connections 03, 04, 05 and 06 are usually already present within the vehicle. If not present,
it is recommended to use cables with a section greater than or equal to 10mm
2
.
Connection 07 can be done with cable the cross-section of which is between 1mm
2
and
2.5mm
2
.
As soon as the ground cable is connected to the
3Link
, the system becomes operational.
Charge completely just after installing the system or after doing any maintenance on
it. When it is fully charged, the display will show 100% on the battery state of
charge (SOC) display.
Close the
3Link
cover by threading the two tabs on the back into the appropriate base
seats; tighten the 2 screws supplied into the holes at the front corners of the cover.
4.3
DISPLAY INSTALLATION
Front View: