5.1 CHARGE

It is recommended to use LiFePo4 lithium battery chargers. However, you can use a mains 
battery charger for AGM/GEL batteries, checking that the maximum voltage supplied by it 
does not exceed 14.5V. The charger must NOT perform any desulfation action. The use of 
battery chargers for flooded lead acid batteries ,

 

although they can completely charge 

3lion

batteries, they can reduce their life. If you have a configurable charger, set the CC/CV 
(constant current/constant voltage) option, by setting the current value equal to or less than 
0.5C, or 50A for the 3L-100, 3L-100B, 3L-100-P models, and 75A for the 3L-150-P model,
and the end--of-charge voltage value to 14.4V.
When the battery is fully charged (the display shows 100%), it is recommended that you 
disconnect or turn off the charger. In the case of alternator charge, this is automatically 
managed by the

 

3Link.

 In fact, 3lion batteries do not need maintenance like lead-acid 

batteries. 

.

52

DISCHARGE

Only for models: 3L-100, 3L-100B

Do not connect equipment with power consumption greater than

 

100A

 

. However,

this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 100A: 55minutes maximum *;
Discharge at constant current of 120A: 30 minutes maximum*;
Discharge at constant current of 130A: 15 minutes maximum*;
Discharge at constant current of 150A: 10 minutes maximum*;
Discharge at constant current of 175A: 1 minute maximum*;
Discharge at constant current of 200A: 10 seconds maximum*;

Only for models: 3L-100-P, 3L-150-P

Do not connect equipment with power consumption greater than

 

150A

 

. However,

this limit may be exceeded, provided that the following limits are met:
Discharge at constant current of 120A: 50 minutes maximum*;
Discharge at constant current of 140A: 20 minutes maximum*;
Discharge at constant current of 160A: 15 minutes maximum*;
Discharge at constant current of 180A: 2 minutes maximum*;
Discharge at constant current of 200A: 20 seconds maximum*;

* Measurements performed at an ambient temperature of 20 °C, and starting temperature of
the lithium battery of 20 °C.

Содержание 3Link

Страница 1: ...All the energy you need www ndsenergy it e mail commer ndsenergy it EN 2 ...

Страница 2: ...on 3Link 2 SAFETY 3 INTRODUCTION 4 INSTALLATION 4 1 3Link INSTALLATION 4 2 MOUNTING SCHEME 4 3 DISPLAY INSTALLATION 5 OPERATION 5 1 CHARGE 5 2 DISCHARGE 6 OPERATION CHECK 7 VERIFIABLE PROBLEMS 8 TECHNICAL CHARACTERISTICS 9 GUARANTEE ...

Страница 3: ...th warm water and seek medical advice immediately Be careful when installing so that the two poles of the 3Lion do not come in contact with each other Use isolated equipment and do not place and or leave metal objects close to the product Always dispose of the battery according to local laws Do not dispose of other industrial waste Protect the poles of the 3Lion from any contact with electrically ...

Страница 4: ...itional lead batteries AGM GEL Free Acid For example it can withstand high charging currents with a very high efficiency or very low current dissipated during that phase which implies a much better charging speed It does not suffer from the typical sulfation of lead batteries it has a very low self discharge rate less than 3 month which combined with a 60 weight reduction and a large number of cyc...

Страница 5: ... battery is disconnected from the system Prepare an area for housing the 3Link box as close as possible to the 3Lion and to the engine battery but never in the engine compartment or in compartments that are not protected from atmospheric agents Remove the two screws in the front highlighted in red in the following figure lift the cover and pull it out to allow convenient access to the connection p...

Страница 6: ... the engine battery and thus the alternator to the service battery when the vehicle has the engine switched on i e the alternator is in operation and signal D is active Below is a representation The installation of the 3Lion 3Link is very simple just intercept in the original system of the vehicle the cable that goes from the service battery to the control unit or to the battery combining relay wh...

Страница 7: ... and 3 of the 3Link it is strongly recommended that you use the terminals for M8 screws DO NOT use the fork type to ensure a perfect and secure connection between the cable and the contact of the 3link as in the following figure 1 2 3 3 4 ...

Страница 8: ... vehicle If not present it is recommended to use cables with a section greater than or equal to 10mm 2 Connection 07 can be done with cable the cross section of which is between 1mm 2 and 2 5mm 2 As soon as the ground cable is connected to the 3Link the system becomes operational Charge completely just after installing the system or after doing any maintenance on it When it is fully charged the di...

Страница 9: ... 7 2 mm are to be made 3 Drill the holes and screw the back cover to the wall using the supplied screws Be careful that once tightened the screws do not protrude beyond the countersinks 4 Pass the communication cable through the specially drilled hole and insert it gently into the connector on the display circuit board DO NOT FORCE THE CONNECTOR The connector has an obligatory direction that must ...

Страница 10: ...lus pens for a more accurate touch on the display but it is important that they do not have a sharp tip which can damage the surface 5 OPERATION The 3Lion 3Link system allows for the automatic management and display of the battery status By means of the display you can interact with the system and show all the information such as voltage current charging with positive sign and discharging with neg...

Страница 11: ...NS Setting the language Click on the desired flag and then on the arrow to confirm your choice Setting the language Click on the desired flag and then on the arrow to confirm your choice Setting the capacity The number below the letter Ah indicates the capacity setting of the battery or the battery pack Click on the keys or until you reach the desired value In the case of a battery pack i e multip...

Страница 12: ...d for at least 3 seconds the Setting key Once the key has been pressed the main screen appears as shown below The state of charge or SOC indication as soon as the system is installed is purely indicative it becomes operational as soon as a full charge of 3Lion is performed When it is fully charged the display will show 100 on the battery state of charge SOC display In the lower left part of the sc...

Страница 13: ...ues that is battery charging In the latter case the thunderbolt symbol is displayed overlapping the notches of the battery You can keep this view active by clicking on the Setting button and then checking the following phrase Always show V and I The engine battery indicator box always shows the voltage value of the battery and if the system is being charged by the alternator the icon of the arrow ...

Страница 14: ...s it briefly you can set the display mode If you press it for a long time you can set the date time the Ah of the 3Lion language In order to preserve battery from discharging after 2 minutes of inactivity the display will decrease its brightness After 15 minutes it will shut off Just touch it to turn it on and resume normal use The system is protected against excessive discharge or overload howeve...

Страница 15: ... acid batteries 52 DISCHARGE Only for models 3L 100 3L 100B Do not connect equipment with power consumption greater than 100A However this limit may be exceeded provided that the following limits are met Discharge at constant current of 100A 55minutes maximum Discharge at constant current of 120A 30 minutes maximum Discharge at constant current of 130A 15 minutes maximum Discharge at constant curr...

Страница 16: ...wn on the display it indicates that the 3Lion battery is charging and in this case skip to step 5 5 If the 3Lion battery is not fully charged and if the check in step 4 has been successful check the display for a positive current and check that the arrow pointing to the engine battery turns red With the ammeter clamp placing it on the wire out of pole 3 of the 3Link it is also possible to verify t...

Страница 17: ...of the amount of available charge SOC does not seem to be accurate or has suddenly indicated a value of less than 5 Run a full charge of 3Lion where full charge means 100 shown on the battery state of charge SOC display ...

Страница 18: ... of cycles estimated 80 DOD 2500 2500 2500 2500 Operating temperature 20 C 60 C 20 C 60 C 20 C 60 C 20 C 60 C Storage temperature 20 C 60 C 20 C 60 C 20 C 60 C 20 C 60 C Self discharge 3 month 3 month 3 month 3 month Humidity Max 95 Max 95 Max 95 Max 95 Connection of poles M8 M8 M8 M8 Battery only weight 13 8Kg 13 3Kg 13 8Kg 20 7Kg Battery only dimensions 327x172h227m m 337x175h190m m 327x172h227 ...

Страница 19: ...0 Battery tolerance voltage Engine battery 3Lion 5 Dimensions 125x123x46mm Weight 480g 3link box display dimensions 175x135h67mm Box weight including display and accessories 785g Technical characteristics of the display Technology TFT 2 83 262k Colours with touch screen Average consumption 76mA 12V maximum brightness 7mA 12V stand by Type of connexion 7m cable with low profile connector Operating ...

Страница 20: ...e together with the warranty card the customer receives this certificate to be filled out in every part by the seller The warranty certificate must be kept and filed for each dispute Failure to submit the certificate and absence of or tampering on the 3Lion and or the 3Link non detachable coupon with the serial number shall invalidate the warranty In the event of a 3Lion and or 3Link failure the c...

Страница 21: ......

Страница 22: ...rize the processing of my personal data under the Decree Law June 30 2003 N 196 customer s signature To be returned in enclosed envelope to NDS Energy s r l Via G Pascoli 169 65010 Cappelle sul Tavo Pe Italy or send via email to commer ndsenergy it NDS ENERGY S r l Via G Pascoli 169 65010 Cappelle sul Tavo PE Italy Phone 39 085 4470396 Fax 39 085 9507049 www ndsenergy it commer ndsenergy it ...