- 25 -
Short
running
LED displays
actual water
temperature, no
error code
displays
1. Fan NOT running
2. Not enough air
ventilation
3.Not enough refrigerant
1. Check the cable
connections between the
motor and fan, if necessary,
they should be replaced
2. Check the location of the
heat pump, and eliminate all
obstacles to assure a good
air ventilation
3 Replace or repair the heat
pump
water
stains
Water stains on
heat pump unit
1. Concreting
2. Water leakage
1. No action
2. Check the titanium heat
exchanger carefully if it
shows any defects
Too much
ice on
evaporator
Too much ice on
evaporator
1. Check the location of
heat pump, and eliminate all
obstacles to assure a good
air ventilation
2. Replace or repair the
heat pump
9. Maintenance
(1) You should check the water supply system regularly to avoid the air entering the system
and occurrence of low water flow, because it would reduce the performance and reliability of
the heat pump.
(2) Clean your pools and filtration system regularly to avoid the damage of the unit as a result
of a dirty or clogged filter.
(3) You should discharge the water from the bottom of the water pump if the heat pump will
stop running for a long time (specially during the winter season).
(4) On any other moment, you should check if the unit has enough water before the unit starts
to run again.
(5) After the unit is conditioned for the winter season, it is preferred to cover the heat pump
with the special winter heat pump cover.
(6) When the unit is running, there is always a little water discharge under the unit.
Содержание MASTER PLUS NDE-08-DCP
Страница 1: ...1 DC Inverter Swimming Pool Heat Pump User and Service manual MASTER PLUS...
Страница 8: ...8 2 2 Exploded views NDE 08 10 11 14 17 20 24 DCP...
Страница 15: ...15 5 Electrical Wiring 5 1 DC INVERTER SWIMMING POOL HEAT PUMP WIRING DIAGRAM NDE 08 10 11 14 17 20 24 DCP...
Страница 34: ...34 4 4 Timer setting In the main interface click to enter timer setting click to add timing...