o
Controls tab => Accessories
: This tab contains the inhibition and pulse
generator channel parameters:
Inhibition channels
: The two Inhibition Channels are inputs used to
detect events such as a running pump or a running motor. These
voltage inputs are connected to a programmable comparator
module. These parameters are reserved for future use.
Pulser Output Channel
:
Enter the pulse period and pulse width,
then click
Set
to activate the pulse generator, or
Stop
to deactivate.
o
Controls tab => Hardware
: This tab contains the acoustic hardware
bandpass and the sensor pre-amplification voltage settings.
Data Analysis side tab
The Data Analysis side tab is divided in sub-tabs (
Data Selection, Localization,
Waveforms, PrPD, Trend and Options
) where acquired data will be analysed,
selected or discarded to create pinpoints and vectors in order to determine the
partial discharge source location in the transformer tank.