background image

 

 

NCR 7460 Terminal Site Preparation 

17 

Cables 

Corporate ID 

Part Number 

Where Used 

Description 

1416-C359-0007  497-0408349  7167, 7197 

RS-232, 9-pin female to 9-pin female 

1416-C266-0040  497-0407943  7167, 7197 

RS-232, 9-pin female to 9-pin female 

1416-C266-0152  497-0409379  7167, 7197 

RS-232, 9-pin female to 9-pin female 

1416-C528-0010  497-0415949  7167, 7197 

USB, 1 meter 

1416-C528-0040  497-0415950  7167, 7197 

USB, 4 meter 

1416-C337-0010 497-0407427 7196 

RS-232, 

integrated 

1416-C337-0040 497-0407429 7196 

RS-232, 

remote 

1416-C337-0152  497-0407430  7196 

RS-232, interface 50' 

1416-C372-0006 497-0409394 Cash 

Drawer Dual Cash Drawer (Y cable) 

1416-C112-0006  497-0409394  Cash Drawer  Cash Drawer (Ext. cable) 

1416-C542-0002 497-0414489 Keyboard 

PS/2, 

Y-Cable 

1416-C338-0005 497-0407490 Keyboard 

Wedge, 

Y-Cable 

1416-C278-0040  497-0405676  5972 

Parallel, Remote Customer Display 

1416-C279-0010  497-0405678  5972 

RS-232, Remote Customer Display 

1416-C279-0040  497-0405679  5972 

RS-232, Remote Customer Display 

1416-C473-0040  497-0413365  5973/5974 

Parallel, Remote Customer Display 

1416-C792-0004  497-0425405  DVI to DVI 

Operator Display 

1416-C634-0040  497-0418406  5945, 5992 

RS-232, 9-pin female to 5945/5992 

1416-C059-0030 497-0008905 LAN 

Ethernet, 

10/100BaseT 

1416-C321-0030  006-8601012  7460 

Power Cord – UK 

1416-C323-0030  006-8601010  7460 

Power Cord – International 

1416-C393-0030  006-8601001  7460 

Power Cord – Japan 

Содержание RealPOS 7460-2

Страница 1: ...NCR RealPOS 7460 2xxx Release 2 0 Site Preparation 200 B005 0000 1480 Issue A ...

Страница 2: ...s without prior notice All features functions and operations described herein may not be marketed by NCR in all parts of the world In some instances photographs are of equipment prototypes Therefore before using this document consult with your NCR representative or NCR office for information that is applicable and current To maintain the quality of our publications we need your comments on the acc...

Страница 3: ...rator must connect this web kiosk to an AC outlet that is near the terminal and is easily accessible Warning This unit contains hazardous voltages and should only be serviced by qualified service personnel The AC line voltage primaries are live at all times when the power cord is connected Therefore disconnect the AC power cord before opening the unit to install features or service this web kiosk ...

Страница 4: ...o the need to comply with the requirements specified electrical wiring and mechanical systems must also comply with all relevant codes laws and regulations It is important that a customer or his agent who is fully conversant with the special requirements of electronic equipment prepare the site The responsibility of ensuring that the site is prepared in compliance with this document remains with t...

Страница 5: ...iable in respect to any comment suggestion or advice given by its staff or in respect to any failure to give advice Finally only the customer can know the full extent of damage that may be caused to his business by reason of failure of the equipment which is to be installed For this reason it is the customer s responsibility to ascertain the extent of any possible damage to his existing or planned...

Страница 6: ...iv References NCR RealPOS 7460 2xxx Site Preparation Guide B005 0000 1480 NCR RealPOS 7460 2xxx Hardware Service Guide B005 0000 1482 NCR RealPOS 7460 2xxx Parts Identification Manual B005 0000 1483 ...

Страница 7: ... 5 2183 Cash Drawer 6 2189 Cash Drawer 6 7197 Thermal Receipt Printer 7 7167 Thermal Receipt Impact Printer 7 7196 Thermal Receipt Printer 8 5973 International VFD Customer Display 10 2336 K007 External CD ROM Drive 11 Component Weights 12 Ventilation Clearance 13 Power Requirements 14 Maximum Input Power Specifications 14 Power Analysis for Terminal and Peripherals 15 Cable Routing Considerations...

Страница 8: ...22 Remote Customer Displays 22 5972 VFD Parallel 22 5972 VFD RS 232 23 5973 5974 VFD Parallel 23 Operator Display Cable DVI to DVI 24 5945 5992 Cable RS 232 24 Communications Cable 25 Ethernet 10 100BaseT 25 Power Cables 25 AC Power 25 Environmental Requirements 26 Barometric Pressure 26 Temperature 26 Humidity 26 AC Power Line Transient Protection 1 Data Line Transient Protection 2 ...

Страница 9: ...vii Revision Record Issue Date Remarks A Sept 02 First issue ...

Страница 10: ...ion interference caused by unauthorized modification of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by NCR The correction of interference caused by such unauthorized modification substitution or attachment will be the responsibility of the user The user is cautioned that changes or modifications not expressly approved by NCR may vo...

Страница 11: ...oration 1700 South Patterson Boulevard Dayton OH 45459 USA declares that the equipment specified above conforms to the referenced EU Directives and Harmonized Standards EU Directive Harmonized Standard s 89 336 EEC EMC EN 55022 1987 CISPR 22 EN 50082 1 Part 1 1992 IEC 801 2 1984 IEC 801 3 1984 IEC 801 4 1988 73 23 EEC Low Voltage EN 60 950 A1 A2 A3 A11 NCR Corporation Retail Solutions Division Atl...

Страница 12: ...x ...

Страница 13: ... before the terminal is installed because site preparation deficiencies may be difficult to detect and correct after installation The terminal consists of separate pieces that may be combined in a variety of configurations Certain combinations are mutually exclusive You must determine the equipment that will actually be installed before proceeding with the site preparation ...

Страница 14: ...gulations and laws including but not limited to electrical building safety and health are met Provide and install auxiliary power or other equipment as required Provide storage or service areas as required Meet all system unit environmental requirements Provide and install floor coverings and environmental systems that limit or control static electricity build up and discharge In general keep the ...

Страница 15: ...eb kiosks associated equipment and devices A dedicated unswitched power line dedicated to the NCR equipment installation is recommended Refer to the Workstation and Peripherals AC Wiring Guide BSTO 2115 53 for store AC wiring requirements The AC outlet must be installed near the web kiosk and easily accessible to the operator LAN Communications The terminal supports Ethernet 10 100 Base local area...

Страница 16: ...7460 20xx 5992 Signature Capture Terminal 5945 Electronic Payment Terminal Transaction Printers Parallel PS 2 KBD 7197 7892 Presentation Scanner 2189 Cash Drawer RS 232 Keyboard 5973 2 x 20 Customer Display USB 7167 2183 TELEQIP Coin Dispenser 2336 K022 5974 4 x 20 Customer Display 7196 ...

Страница 17: ...NCR 7460 Terminal Site Preparation 5 Dimensions 7460 Terminal 20129 250 mm 9 75 in 28 o 90 o 325 mm 12 75 in 350 mm 13 75 in 292 mm 12 in 382 mm 15 0 in ...

Страница 18: ...ash Drawer 18038 455 mm 17 9 in 108 mm 4 25 in 450 mm 17 7 in Operating and Service Clearance for Drawer 263 mm 10 4 in 2189 Cash Drawer 16676a 133 mm 5 25 in 330 mm 13 in 18 25 in Operating and Service Clearance for Drawer 464 mm 527 mm 20 5 in ...

Страница 19: ...197 Thermal Receipt Printer 19712d 146 mm 7 75 in 156 mm 6 25 in 184 mm 7 25 in Top Cover Open 256 mm 10 1 in 7167 Thermal Receipt Impact Printer 19711d 190 mm 7 5 in 174 mm 7 0 in 262 mm 10 3 in 316 mm 12 5 in Top Cover Open 296 mm 11 7 in ...

Страница 20: ...8 NCR 7460 Terminal Site Preparation 7196 Thermal Receipt Printer 108 mm 4 25 in 140 m 5 50 in 146 mm 5 75 in 254 mm 10 00 in 17306 ...

Страница 21: ...NCR 7460 Terminal Site Preparation 9 5974 4x20 Remote Customer Display 20131 95 mm 3 75 in 356 mm 14 1 in 50 mm 3 5 in 95 mm 3 75 in 180 mm 7 in 110 mm 4 25 in ...

Страница 22: ...10 NCR 7460 Terminal Site Preparation 5973 International VFD Customer Display 350 mm 13 8 in 45 mm 1 8 in 95 mm 3 75 in 95 mm 3 75 in 110 mm 4 3 in 262 mm 10 3 in 17236a ...

Страница 23: ...Site Preparation 11 2336 K007 External CD ROM Drive 23 mm 0 9 in 155 mm 6 1 in 218 mm 8 6 in 16951 Note Allow 75 mm 3 in clearance in the back of the NCR 2336 K007 External CD ROM Drive for connector and cable clearance ...

Страница 24: ...CD Operator Display only 2 9 8 6 7460 Base Unit No LCD Operator Display 4 6 12 3 2189 2113 Cash Drawer 9 5 20 9 7453 K005 Cash Drawer 11 4 25 15 5972 Remote Customer Display 0 7 1 5 7167 Receipt Impact Printer 4 5 10 5 7197 Thermal Receipt Printer 1 3 2 8 7158 Receipt Impact Printer 4 8 10 5 7194 Thermal Receipt Printer 1 3 2 8 7196 Thermal Receipt Printer 1 8 3 4 2336 K007 External CD ROM Drive 0...

Страница 25: ...al Site Preparation 13 Ventilation Clearance Leave the minimum clearances shown below for proper cooling conditions for the terminal 20143 Minimum Vertical Clearance Minimum Horizontal Clearance 76 mm 3 in 25 mm 1 in ...

Страница 26: ...hase selectable 120 240 volt AC 90 Watt power supply The following tables show operating specifications for the power supply Maximum Input Power Specifications 120 volt 240 volt Voltage Ranges 90 136 VAC 198 257 VAC Frequency 50 60 Hz 50 60 Hz Current A 4 0 2 0 Power Factor typical 0 25 0 25 ...

Страница 27: ...ls Options subtract from Current Available above Hard Disk Drive 3 5 Seagate ST320410A 1 00 Hard Disk Drive 3 5 Fujitsu MPF3102AT 0 50 Keyboards 0 30 Display 2x20 LCD Powered from Serial Port 12V to 5V conversion in cable 0 10 Display 2x20 VFD Powered from Serial Port 0 50 5992 Signature Capture Device 0 80 5945 Electronic Payment Device 0 50 7837 Hand held Scanner Powered from Serial Port 0 30 78...

Страница 28: ...16 NCR 7460 Terminal Site Preparation Cable Routing Considerations External cables connect to the front of the unit behind the Front Cover and are routed under the bottom of the unit 20144 ...

Страница 29: ...Cash Drawer Dual Cash Drawer Y cable 1416 C112 0006 497 0409394 Cash Drawer Cash Drawer Ext cable 1416 C542 0002 497 0414489 Keyboard PS 2 Y Cable 1416 C338 0005 497 0407490 Keyboard Wedge Y Cable 1416 C278 0040 497 0405676 5972 Parallel Remote Customer Display 1416 C279 0010 497 0405678 5972 RS 232 Remote Customer Display 1416 C279 0040 497 0405679 5972 RS 232 Remote Customer Display 1416 C473 00...

Страница 30: ...Site Preparation Corporate ID Part Number Where Used Description 1416 C408 0030 006 8601011 7460 Power Cord SEV 1416 C410 0030 006 8601019 7460 Power Cord Australia 1416 C419 0030 006 8601020 7460 Power Cord U S Twist lock ...

Страница 31: ...6 C359 0007 497 0407943 4 m 1416 C266 0040 497 0409379 15 m 1416 C266 0152 RS 232 Printer RS 232 Terminal Access Hole Diameters 38 0 mm 1 5 in 38 0 mm 1 5 in 7167 7197 Printer USB 18433 Type A USB 15 mm 0 63 in Access Hole Diameters 6 4 mm 0 25 in 497 0415949 1 meter 1416 C528 0010 498 0415950 4 meter 1416 C528 0040 P1 Type B USB P2 1 2 3 4 1 2 3 4 ...

Страница 32: ...Printer RS 232 20127a 9 pin D shell Receptacle 25 pin D shell Plug 497 0407427 1 0 m 1416 C337 0010 497 0407429 4 m 1416 C337 0040 497 0407430 15 2 m 1416 C337 0152 RS 232 Printer RS 232 Terminal 63 5 mm 2 5 in Access Hole Diameters 38 mm 1 5 in ...

Страница 33: ...inter Cash Drawer Cable Modular 6 Pin Jack Modular 6 Pin Plug Access Hole Diameters 30 0 mm 1 2 in 16 0 mm 0 63 in PS 2 Y Cable 17894 PS 2 Mouse PS 2 Terminal 6 pin Mini DIN Plug 6 pin Mini DIN Receptacle PS 2 Keyboard 5 pin Mini DIN Receptacle 51 mm 2 in 497 0414489 0 2 m 1416 C542 0002 Access Hole Diameters 19 0 mm 0 75 in 19 0 mm 0 75 in ...

Страница 34: ...OM Display Access Hole Diameters 38 0 mm 1 5 in 38 0 mm 1 5 in Remote Customer Displays 5972 VFD Parallel 20277a Power 8 pin Microfit Receptacle Customer Display Terminal Parallel Port 497 0405676 4m 1416 C278 0040 25 pin D Shell Receptacle 25 4 mm 1 0 in 57 1 mm 2 25 in Access Hole Diameters 19 mm 0 75 in 30 Position Microfit Receptacle ...

Страница 35: ...ofit Receptacle Power 19 mm 0 75 in 8 pin Microfit Receptacle 497 0405678 1 0 m 1416 C279 0010 497 0405679 4 0 m 1416 C279 0040 5973 5974 VFD Parallel 20280a Power 8 pin Microfit Receptacle Customer Display Terminal Parallel Port 497 0413365 4m 1416 C473 0040 25 pin D Shell Receptacle 25 4 mm 1 0 in 57 1 mm 2 25 in Access Hole Diameters 19 mm 0 75 in 30 Position Microfit Receptacle ...

Страница 36: ... 0422831 400 mm 1416 C792 0004 24 Pin DVI D Plug 24 Pin DVI D Plug DVI Terminal DVI Operator Display 63 5 mm 2 5 in Access Hole Diameters 63 5 mm 2 5 in 5945 5992 Cable RS 232 20149 Sub Miniature D Shell 9 Pin Receptacle RS 232 5945 5992 RS 232 Terminal 497 0418406 4 m 1416 C634 0040 ...

Страница 37: ...m 1416 C059 0030 Access Hole Diameters 19 0 mm 0 75 in 19 0 mm 0 75 in Power Cables AC Power 15405 45 mm 1 75 in Access Hole Diameter Terminal 006 1009037 U S The following power cables not shown also have an IEC connection of 45 mm 006 8601001 Japan Twist Lock 006 8601010 International 006 8601011 SEV 006 8601012 U K 006 8601019 Australia ...

Страница 38: ... locations where temperature changes exceed the temperature restrictions Temperature Parameter Restriction Operating 5oC to 45oC 41oF to 113oF dry bulb Storage 10oC to 50oC 14oF to 122oF three months Shipping 40oC to 60oC 40oF to 140oF one week Dew Point 26oC 79oF maximum Humidity The 7460 Retail Terminal is designed to operate within the humidity ranges shown below Continuous operation must be av...

Страница 39: ...NCR 7460 Terminal Site Preparation 27 ...

Страница 40: ......

Страница 41: ...r component failure as a result of power quality problems NCR accepts no liability for any such occurrence or for its consequences When power transient suppression is required the suppressors used should meet the following minimum requirements Dissipate energy to match the appropriate application categories as defined by IEEE Standard 587 Be of the voltage limiting clipping or tracking filter type...

Страница 42: ...of the voltage limiting type and must self recover after passage of the transient Insert less than 5 ohms resistance and minimal inductive and capacitive loading at the operating frequency for data lines in order to avoid signal degradation Be installed in accordance with all applicable local state and national electrical codes and regulations Note In certain countries NCR is able to supply both p...

Страница 43: ...e Routing 16 Cables 17 CD ROM Drive 11 Configuration Diagram 4 Customer Display 10 Customer Responsibilities 2 D Dimensions 5 Dimensions and Weight Weight 12 E Environmental Requirements 24 Barometric Pressure 24 Humidity 24 Temperature 24 H Humidity 24 L LAN 3 M Maximum operating altitude 24 O Operating range of barometric pressure 24 P Power Analysis for Peripherals 15 Power Requirements 14 Prin...

Страница 44: ...7197 Thermal Receipt Printer 7 T Temperature 24 Terminal Power Cables 23 V Ventilation Clearance 13 W Weight 12 Wiring Requirements 3 ...

Отзывы: