NCR Remote Compact Display (7825)
3
Preparing the Site
This section provides the information necessary to prepare a site to NCR specifications
prior to installing the NCR Remote Compact Display. The site must be properly
prepared before the scanner display is installed because site preparation deficiencies
may be difficult to detect and correct after installation.
Environmental Considerations
The NCR Remote Compact Display operates in most standard working environments.
The following table gives the various environmental requirements.
Physical Variable
Operating
Storage
Transit
Temperature
0°C to 50°C
(32°F to 122°F)
-10°C to 50°
(14°F to 122°F)
-40°C to 60°
(-40°F to 140°F)
Temperature
Change
-
15°C per hour
(59°F per hour)
20°C per hour
(68°F per hour)
Relative Humidity
5–95%
No Condensation
5–95%
No Condensation
5–95%
No Condensation
Note:
Condensation may occur when the equipment is transferred from cold to warm
areas during shipment. The equipment design shall permit operation after flash
condensation has occurred, provided a drying out process has been accomplished, and
the equipment stabilized to the operating environment.
Power Requirements
AC Power Requirements
•
120 VAC, 60 Hz (US, Canada, and others) through a wall mount power supply
•
90 – 264 VAC, 50 – 60 Hz through a Universal Input power supply
DC Power Requirements
•
5 VDC at 10 mA max (for Single Display)
•
5 VDC at 20 mA max (for Dual Display)