567HUPLQDWRU%\WH
8VHUV*XLGH
RS-232 Terminator Byte
Controls the use of terminator bytes. If you use an
RS-232 Terminator Byte, it goes at the end of the message
sent to the host terminal or PC. If you included a BCC (RS-
232 Parameters -2 programming mode), it follows the
Terminator Byte and includes the Terminator Byte in the
calculation.
Contains two selections: Disable and Enable. Scan the Hex 0
tag to disable the Terminator Byte or scan the Hex 1 tag to
enable it. The default is Enable.
Specifies what ASCII code to use for the Terminator Byte.
Enter your selection by scanning the two appropriate Hex tags
as listed in the ASCII Code Chart in Appendix A. Although
you can select any value from 01 through 7F (Hex), the End
of Text (ETX) ASCII Code is recommended (Hex 03 or
Carriage Return, which is Hex 0D). If do not use Hex 03, 01 -
0F (Hex) are recommended. Scan the two appropriate Hex
tags (Hex 0 through Hex 7 for the first character and Hex 0
through Hex F for the second). The default is 0D.
Terminator Byte
ASCII Code