background image

National Comfort Products

539 Dunksferry Road • Bensalem, PA 19020 • (215) 244-1400 • 1-800-523-7138 • Fax: (215) 244-9579

10

ITEM

DESCRIPTION

NCHP-018

NCHP-024

NCHP-030

1

2

3

4

Contactor

Dual Run Capacitor

30-5 mFd / 370V

35-5 mFd / 370V

30-7.5 mFd / 370V

Low Pressure Switch

(Optional)

High Pressure Switch

(Optional)

14262082

N/A

14225375

N/A

14265020

14265023

14262082

14225376

N/A

N/A

14265020

14265023

14262082

N/A

N/A

14225377

14265020

14265023

5

Compressor

H21J17BABCA

H21J22BABCA

H21J25BABCA

14210095

N/A

N/A

N/A

14210097

N/A

N/A

N/A

14210099

6

7

Liquid Service Valve

Vapor Service Valve

14258603A

14258605A

14258603A

14258606A

14258603A

14258606A

8

9

10

Defrost Control

Defrost Sensor

Accumulator

14260020

14260014

14255005

14260020

14260014

14255005

14260020

14260014

14255005

ITEM

DESCRIPTION

NCPC-018

NCPC-024

NCPC-030

11

12

13

14

15

16

17*

18

19

20

21

Outdoor Coil

Blower Motor

0.25 HP 1140 RPM

0.50 HP 1575 RPM 

Blower Wheels

(7.6” OD x 8.0”)

Blower Housings

Inlet Ring 

(2 req’d)

Motor Blower Mount 

Access Panel 1000

Top Panel 1000

Right Side Panel

Left Side Panel

Wire Grille 1000

14208028 

14270038

N/A

14267007

14214013

14214021

14256933S

14256936Y

14256939S

14256938HP

14256937HP

14269001

14208029 

14270038

N/A

14267007

14214013

14214021

14256933S

14256936Y

14256939S

14256938HP

14256937HP

14269001

14208029 

N/A

14270036

14267007

14214013

14214021

14256933S

14256936Y

14256939S

14256938HP

14256937HP

14269001

22

23

24

25

26

27

Condensate Pan Heater

Heater Thermostat

Reversing Valve

Reversing Valve Coil

Expansion Valve

Muffler or Check Valve

14299104

14299105

14206026

14206027

14211005

14275341

14299104

14299105

14206026

14206027

14211014

14275341

14299104

14299105

14206026

14206027

14211008

14275639

±

 Not shown

REPLACEMENT PARTS GUIDE     

      

NCHP SERIES 1000

Содержание NCHP-018

Страница 1: ...st be 3 flashed Bottom flashing to cover the full foot print of unit and extend up 2 on 3 sides All openings around the top sides and bottom must be caulked and sealed Care must be taken not to plug the openings in the front of the base pan of the unit If the optional wall sleeve is used caulk the spaces between the sleeve and the wall Completely fill the clearance between the unit and the wall sl...

Страница 2: ...haust air Important The outdoor unit is fully charged at the factory for the recom mended model of indoor unit With other models of indoor units the charge must be adjusted Be sure both service valves are closed during tubing installation and leak checking to avoid loss of charge A biflow liquid filter drier must be installed in the liquid line SPORLAN HPC 103 C or similar The unit has internally ...

Страница 3: ...e alloy is used Step 5 This is not a back seating valve To open the valve re move the valve cap with an adjustable wrench Insert a 3 16 or 5 16 hex wrench into the stem Back out counter clockwise until the valve stem just touches the retaining ring Step 2 Wrap a wet rag around the copper stub before brazing Step 4 After brazing quench with a wet rag to cool the joint and remove any flux residue Ev...

Страница 4: ...vent high head pressure which would shut down the unit Connect the charging cylinder to the manifold gauge set 1 Open the charging cylinder valve and bleed air out of the charging hose at the manifold gauge set connection Tighten the manifold gauge set charging connection Open 2 the main manifold gauge set valve and introduce refrigerant into the system Step 4 Evacuation Step 5 Refrigerant Chargin...

Страница 5: ...an to resume operation If the outdoor temperature is cold enough to produce icing on the outdoor coil during the heating mode approximately 34 the condensate heater will be energized through the heater thermostat located in the control box This heater stays ener gized during cold weather to keep any defrosted water from re freezing in the pan The condensate pan under the coil must be piped per ite...

Страница 6: ...90 42 38 35 33 30 29 26 24 21 19 17 14 95 33 38 35 33 31 29 27 24 22 20 18 15 75 96 39 36 34 32 29 27 25 22 20 18 15 80 76 39 37 35 32 30 28 26 24 22 19 18 85 60 39 37 35 33 31 29 26 24 22 20 18 90 48 40 38 35 33 31 29 26 24 22 20 18 95 38 40 38 36 33 31 29 27 25 22 20 18 80 84 42 40 38 36 34 32 30 28 27 25 23 85 67 42 41 39 37 35 33 31 29 27 25 23 90 54 44 42 40 38 36 34 32 31 29 27 25 95 43 45 4...

Страница 7: ...Figure 2 Wiring Schematic Heat Pump Units NCHP 018 024 030 1019 3019 7 ...

Страница 8: ...1 2 18 1 2 3 8 5 8 3 4 26 28 1 2 18 1 2 3 8 3 4 3 4 26 28 5 8 18 1 2 3 8 3 4 3 4 Width Height Length Liquid Valve Vapor Valve Drain Connection MPT CAP COOLING 18 000 24 000 28 500 CAP HEATING 47 F 17 000 22 500 26 000 ELECTRICAL 208 230 60 1 12 14 6 25 208 230 60 1 12 17 7 30 208 230 60 1 12 19 8 30 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 7 0 41 9 9 61 10 7 61 RLA Amps ...

Страница 9: ... 3 4 23 3 4 32 18 1 2 3 8 3 4 3 4 23 3 4 32 18 1 2 3 8 3 4 3 4 Width Height Length Liquid Valve Vapor Valve Drain Connection MPT CAP COOLING 18 000 24 000 29 000 CAP HEATING 47 F 17 000 22 500 26 000 ELECTRICAL 208 230 60 1 12 14 6 25 208 230 60 1 12 17 7 30 208 230 60 1 12 19 8 30 Volts Hertz Phase Min AWG Wire Min Cir Ampacity Max Fuse COMPRESSOR 7 0 41 9 9 61 10 7 61 RLA Amps LRA Amps FAN MOTOR...

Страница 10: ...ESCRIPTION NCPC 018 NCPC 024 NCPC 030 11 12 13 14 15 16 17 18 19 20 21 Outdoor Coil Blower Motor 0 25 HP 1140 RPM 0 50 HP 1575 RPM Blower Wheels 7 6 OD x 8 0 Blower Housings Inlet Ring 2 req d Motor Blower Mount Access Panel 1000 Top Panel 1000 Right Side Panel Left Side Panel Wire Grille 1000 14208028 14270038 N A 14267007 14214013 14214021 14256933S 14256936Y 14256939S 14256938HP 14256937HP 1426...

Страница 11: ... DESCRIPTION NCHP 018 NCHP 024 NCHP 030 11 12 13 14 15 16 17 18 19 20 21 Outdoor Coil Blower Motor 0 25 HP 1140 RPM 0 50 HP 1575 RPM Blower Wheels 7 6 OD x 8 0 Blower Housings Inlet Ring 2 req d Motor Blower Mount Access Panel 3000 Top Panel 3000 Right Side Panel Left Side Panel Wire Grille 3000 14208026 14270038 N A 14267007 14214013 14214021 14256933S 14256969S 14256967S 14256973S 14256974HP 142...

Страница 12: ... that defective parts be returned to verify and identify the cause of the defect LIMITATION OF WARRANTIES ALL IMPLIED WARRANTIES INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH EACH LIMITED WARRANTY IS GIVEN SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU THE EX PRESSED W...

Страница 13: ... have to wait for a replacement compressor to be shipped from Bensalem PA The situation may present itself where it is better for the compressor to be returned to National Comfort Products during the 20 month Bristol warranty period NCP will also honor the Bristol 20 month warranty period All returned compressors must have the tubing connections closed with rubber plugs or brazed shut National Com...

Страница 14: ...seamless rifled copper tubes CABINET Unit cabinet shall be constructed of heavy gauge galvanized or aluminized steel The steel shall be treated by phosphate washes prior to electrostatically applied and oven baked paint FACTORY CHARGED Each unit shall be charged with R 22 for proper operation with recommended indoor coil and 10 foot tubing SERVICE VALVES Each unit shall be equipped with liquid and...

Страница 15: ...SPLIT SYSTEM HEAT PUMP INSTALLATION INSTRUCTIONS Rev 09 09 ...

Страница 16: ......

Отзывы: