NCP Match Lit Скачать руководство пользователя страница 8

 

 

Service 

We  suggest  that  our  products 
be  serviced  by  a  professional 
certified  in  the  US  by  the 
National  Fireplace  Institute 
(NFI) as NFI Gas Specialists. 

 

9)

 

Maintenance 

 

WARNING: 

Any guard or protective device removed for servicing must be replaced prior to 

operating the fire pit.

 

WARNING: 

Installation and repair should be done by a qualified service person.  Fire pits 

should be inspected prior to use and at least annually by a qualified service person. 

WARNING

:  Ensure gas and power (if applicable) are shut off and fire pit is cool before servicing.

 

 

Keep fire pit covered at all times when not in use. 

 

Keep any debris out of fire pit- clean as needed.  

 

In some areas of the country spiders or insects have been known to build nest and or 
lay eggs in the venture holes of the air-mixer for LP units.  This can cause fuel to fill 
the fire feature cavity and result in personal injury or property damage. Periodical 
inspection by a qualified service technician of the air-intake is required to ensure your 
fire feature performs properly.   

 

Ring Cleaning: (1 x YR) If flames exhibit any abnormal shapes or behavior, or if 
burner fails to ignite properly, then the burner holes may require cleaning. The 
appliance can be cleaned by carefully removing the logs and media to allow access to burner. Use a brush to carefully 
remove dust, spider webs, and loose particles from base, logs, and fire ring itself. If evidence of damage, fire ring must 
be replaced with fire ring specified by manufacturer. 

 

10)

 

Troubleshooting 

 

 

Below are some potential causes and countermeasures to the symptoms indicated in bold.  Please contact your retailer or 

certified technician for service & repair. 

 

Below are some potential causes and countermeasures to the symptoms indicated in bold. If still unable to resolve issue, please 
contact your retailer or certified technician.   

Will Not Light  

1. Air in gas line.                    

 

If new install, may take several attempts to purge air  

2. Debris in gas line.              

 

Confirm gas line is clear (insulation, dirt, plastic, excessive pipe sealer etc..) 

3. Gas Pressure Improper        

 

Confirm proper gas pressure found (Section 1) 

  

Will Not Stay Lit  

1. Gas Pressure Improper                   

 Confirm proper gas pressure found (Section 1)  

2. Improperly applied media                

Review Media in (Section 5) 

  

Noise 

 

1. Whistling Sound                        

Change Flex line routing.  

 

11)

 

Warranty 

        

 

Limited Warranty

 

 

      

  

  

The manufacturer warranties fire pits against manufacturing defects that prevent  

safe and correct function as follows: 

  

●Electronics, Gas Valve, & Pilot Assembly: Commercial-1yr.; Residential- 3 yrs.  

 

●Stainless Steel Pan, Fire Ring, & Valve Box: Commercial-1yr.; Residential 5yrs. 

This commences from the date of original sale / shipment from manufacturer. 
         This warranty is for parts and in-house labor. The defective product must be  
sent back to manufacturer with a Return Merchandise Authorization (RMA) issued by  
manufacturer for that specific product and any other additional information for the nature of the  
defect or warranty claim. 
         The warranty does not cover items that have been damaged by overheating, 
modification, abuse, or improper storage. Also any labor involving installation or 
maintenance with the unit is not covered. 
         This warranty excludes claims for consequential, indirect-collateral expenses  
arising from product defects or warranty recovery.   

 

 
 
 

Содержание Match Lit

Страница 1: ...maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If yo...

Страница 2: ...ucts be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in Canada by WETT Wood Energy Technical Training Installer must follow all instructions carefully to ensure proper performance and saf...

Страница 3: ...Pit 48 From Structure or Combustibles Overhead Clearance Nothing Over Head Select a location with good drainage Choose a location that allows easy access for installation and maintenance of the fire pit Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat and flame 3 Construction of the Enclosure WARNING All fire pits must have a...

Страница 4: ...nd pressure Perform leak test on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply If using flex line avoid sharp bends with flex line to prevent whistling Turn on gas supply and perform leak test on all inlet connections Repair as needed Position fire pit safely with access to all gas connections for testing Once fire pit is li...

Страница 5: ...eave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition Decorative Glass Application 1 Install your fire pit per instructions 2 Fill Pan with glass Cover Burner with 1 8 to of glass Do not over fill with g...

Страница 6: ...Apply pipe dope or gas rated tape to all threads 7 Connect flex line from valve to burner see Steps 8 9 LP Gas Burner Assembly 8 LP burner assembly sequence Note Must use the LP Orifice Burner Pan Close Nipple Coupler Air Mixer Coupler Fitting Flex Line Air Mixer Natural Gas LP Gas Configuration WARNING Confirm Gas In is towards control valve or shutoff valve Installing backwards will result in se...

Страница 7: ...ch can break and cause personal injury or damage WARNING Solid fuels shall not be burned in the fire pit Leaves sticks wood paper clothing food material should be kept away from the fire pit Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in Section 2 Selecting the Location WARNING If lava rock is ...

Страница 8: ...causes and countermeasures to the symptoms indicated in bold Please contact your retailer or certified technician for service repair Below are some potential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If new install may take several attempts to purge air 2 Debris...

Страница 9: ...t the edges of the caps fit tightly in the circle Step 1 Level the pad Level a 48 circular area of gravel or rock on compacted soil with the top of the pad being 1 below grade Fire Pit enclosure parts list 19 blocks 1 Key valve block block with hole 8 top caps Important Product Information The fire pit concrete blocks can crack due to high temperatures These blocks are manufactured to meet industr...