4
7-
When the start process finishes, the main display is shown. The main display has the status
information of the NCM-OR-200. If there is no RF alarm, then the RF LED lights up green. If RF LED
lights up red that means one or more output RF level is out of range. If no optical input alarm, the PD
LED lights up green. When optical alarm occurs, PD LED lights up red.
Status:
OFF-Disable module, ON-Enable Module, ALM-Alarm in the module(FigEx: In this case RX#1is
disable(OFF), RX#2 and RX#3 are enable and work ok(ON), RX#4 is enable but alarmed(ALM)).
***While OR-200 stays on main display, it is monitoring the principal parameters of the receiver and
sends serial data via RS-232 to monitor on personal computer.
RX#1 RX#2 RX#3 RX#4
X OFF ON ON ALM
8-
the main display will show a speaker symbol. An “X” symbol, if the alarm sound is disabled and you will
not hear the alarm.
When an alarm condition is detected, you will hear a beeping sound if the sound alarm is enabled and
GENERAL ALARM SOUND
ENABLE ^
GENERAL ALARM SOUND
DISABLE ^
9- OR-200 can disable or enable the receiver modules. Use the “R” button to find the general setup RX#x like the
picture, then change to disable or enable with “U” or “D” button. Push “R” to the next RX#x+1 display. Push “F”
to return to RX#x.
GENERAL SETUP RX#1
DISABLE ^
GENERAL SETUP RX#1
ENABLE ^
8125 NW 64th Street, Miami, Florida 33166
4 Channels Optical Receiver
NCM-OR-200